VOLTCRAFT MSO-2072USB Operating Instructions Manual Download Page 3

®

 

•   Avoid the following adverse conditions at the installation location and during 

transport:

 

  -  Extreme cold or heat, direct sunlight

 

  -  Dust or flammable gases, fumes or solvents

 

  -  Strong impacts, blows

 

•   Do not leave packaging material carelessly lying around, since it could become a 

dangerous plaything for children.

 

•   Handle the product with care; it can be damaged by impacts, blows, or accidental 

falls, even from a low height.

 

 •   Never reach beyond the grip surface of the probes and never touch the measur-

ing point during the measuring process. There is the risk of a dangerous electrical 

shock.

 

 •   Never exceed the max. allowable measurement voltage during a measurement. 

This presents a fatal hazard.

 

 •   Do not use in the immediate proximity of strong magnetic or electromagnetic 

fields or transmission aerials. These can affect the measurement.

 

 •   Prior to each measurement, check your instrument and the measuring leads for 

damages. Never take any measurements if the protecting insulation is defective.

 

•   Be especially careful when dealing with voltages higher than 50 V/AC or 75 V/DC. 

Even at such voltages you can get a life-threatening electric shock if you come 

into contact with live electric wires.

 

•    First connect the BNC output of the probe to the oscilloscope attachment before 

you connect the probe with the electrical circuit to be tested. When the measure-

ment is completed, please disconnect the measuring contacts from the measuring 

circuit first, before disconnecting the BNC probe output from the oscilloscope 

attachment.

 

•   The measurement device is only suitable for use in dry interiors. Avoid using the 

device in a damp or wet environment.

 

•    Pay attention to the operating instructions in the measurement program (Help).

 

•   Always ensure that the fan output “4” on the housing is not covered by anything. 

There is a risk of overheating of the measurement device.

 

•   Always ensure that the test probes are perfectly clean. Polluted or corroded test 

probes may affect the measurement result.

 

•   Store the measurement device and all of its accessories carefully in the storage 

bag when it is no longer needed.

controls

MAX ±20V

1

2

3

4

 

5

6

7

8

9

10

1  Power supply 

6  BNC input Channel 1

2  USB connection  

7  BNC input Channel 2

3  BNC trigger input 

8  Connection for the logic analyser

4  Fan 

9  Calibration output

5  Status LEDs 

10  Measurement connection, Ground potential

installation of the measUrement proGram

Before you connect the MSO to a computer, first install the measurement software. Switch on 

your computer and insert the enclosed software CD into the CD drive of your computer. The 

automatic start mode will automatically start the installation of the measurement program. If 

the program does not start automatically, open the file “setup.exe” in the folder on the CD.
Please follow the on-screen instructions.

 

Leave the CD in you computers’ drive for device installation.

G

 operatinG instrUctions

oscilloscope attachment “mso-2072UsB”

item no. 1086338

intended Use

The oscilloscope attachment, in conjunction with a Windows

®

-based computer with a USB 

2.0 interface, serves as a high-quality digital storage oscilloscope for visual representation of 

electrical magnitudes and signals up to 70 MHz. For the measurement, two input channels 

that are independent of each other are available. Spectrum analysis is possible through the 

FFT (Fast Fourier Transform) analysis function. The test probes connect to the oscilloscope 

attachment via BNC plug. The operation and representation occur through the measurement 

software provided on the computer. This thereby presents a real digital oscillograph user 

interface. Using the auto-set function in the software, you can automatically adjust all settings 

to the respective measurement signal. The measured data can be saved through the software 

and even exported into Excel

®

. Automatic measurement functions and cursor for signal meas-

urement are also available. The stated measurement voltage given on the device may never 

be exceeded. If necessary, use distributor test probes.
Measuring under adverse ambient conditions such as dust and flammable gasses, vapours or 

solvents is not admissible.
Always observe the safety instructions and all other information included in these operating 

instructions.
This product complies with the applicable national and European requirements. All names of 

companies and products are the trademarks of the respective owners. All rights reserved.

contents

•  Oscilloscope attachment
•  Storage bag
•  Carrying strap
•  Power adaptor
•  USB Connection cable
•  2 test probes
•  20-Pin logic analyser connection cable
•  20 x sprung hooks (mini-gripper)
•  Measurement program and driver CD
•  Operating instructions

explanation of the symBols

   

In the operating manual, an exclamation mark inside a triangle indicates important 

instructions.

The arrow symbol indicates special information and advice on operating the device.

safety instrUctions

 

 the warranty will be void in the event of damage caused by failure to observe 

these safety instructions! we do not assume any liability for any resulting 

damage!

 

 we shall not accept liability for damage to property or personal injury caused 

by incorrect handling or non-compliance with the safety instructions. in such 

cases, the warranty will be null and void.

 

•   The unauthorised conversion and/or modification of the product is not permitted 

for safety and approval reasons (CE). Never dismantle the product.

 

•   The product is not a toy. Therefore, be especially careful when children are 

around. 

 

  Use the product where it is out of the reach of children. 

 

•   Never use the product immediately after taking it from a cold room to a warm one. 

The condensation that forms might damage the product under certain circum-

stances.

Version 06/14

Summary of Contents for MSO-2072USB

Page 1: ...isungen am Bildschirm Lassen Sie die CD für die Geräteinstallation noch im Laufwerk Ihres Computers D BEDIENUNGSANLEITUNG Oszilloskop Vorsatz MSO 2072USB Best Nr 1086338 BestimmungsgemäSSe Verwendung Der Oszilloskop Vorsatz dient in Verbindung mit einem Windows basierenden Computer mit einer USB 2 0 Schnittstelle als vollwertiges digitales Speicheroszilloskop zur visuellen Darstellung von elektris...

Page 2: ...hr Modell aus Die Messsoftware ist nun einsatzbereit Über die Softwaretaste AUTO werden alle Parameter am MSO automatisch einge stellt so dass eine optimale Signaldarstellung am Bildschirm erfolgt Wartung und Reinigung Das Messgerät ist für Sie wartungsfrei Um die Genauigkeit des Messgerätes über einen langen Zeitraum hinweg zu gewährleisten empfiehlt es sich das Produkt einmal jährlich kalibriere...

Page 3: ...the CD Please follow the on screen instructions Leave the CD in you computers drive for device installation G OPERATING INSTRUCTIONS Oscilloscope attachment MSO 2072USB Item no 1086338 Intended use The oscilloscope attachment in conjunction with a Windows based computer with a USB 2 0 interface serves as a high quality digital storage oscilloscope for visual representation of electrical magnitudes...

Page 4: ...sary select your model The measurement software is now ready to use Using the AUTO software button all parameters on the MSO are automatically adjus ted so that an optimal signal representation appears on the screen Maintenance and cleaning The product is maintenance free In order to ensure the accuracy of the measurement device over a long period it is recom mended to have the device calibrated o...

Page 5: ...n Laissez le CD pour l installation de l appareil dans le lecteur de votre ordinateur F NOTICE D EMPLOI Adaptateur d oscilloscope MSO 2072USB N de commande 1086338 Utilisation conforme L adaptateur d oscilloscope sert en association avec un ordinateur doté d un système d ex ploitation Windows avec une interface USB 2 0 d oscilloscope à mémoire numérique valable pour la représentation visuelle de g...

Page 6: ...à l emploi La touche logicielle AUTO définit automatiquement tous les paramètres du MSO pour obtenir une représentation optimale des signaux sur l écran Maintenance et nettoyage L appareil de mesure ne nécessite aucun entretien Pour que l appareil de mesure reste précis pendant un long laps de temps nous vous recom mandons de calibrer le produit une fois par an Ne le nettoyez jamais lorsqu il est ...

Page 7: ...uw computer Het meetapparaat wordt automatisch door het besturingssysteem herkend Volg nu de aanwijzingen op het scherm op O GEBRUIKSAANWIJZING Oscilloscoop hulpapparaat MSO 2072USB Bestelnr 1086338 Beoogd gebruik Het oscilloscoop voorzetapparaat wordt gebruikt in combinatie met een Windows computer met een USB 2 0 interface als een volledig digitaal oscilloscoopgeheugen voor visuele weer gave van...

Page 8: ...arborgen is het raad zaam het product elk jaar te laten kalibreren Maak het meetapparaat nooit schoon als het is ingeschakeld Om het te reinigen is een droge zachte schone doek voldoende Gebruik geen agressieve schoonmaakmiddelen hierdoor kan het product verkleuren Druk tijdens het schoonmaken niet te hard op het oppervlak om krassen te voorkomen Afvoer Verwijder het product aan het einde van zijn...

Reviews: