b) Measuring voltage

The diagram below shows how to connect the adapter to a multimeter or other similar 

measurement device. The measurement device is not included and must be purchased 

separately. Two measuring adapters are required to measure the voltage.

Fig.2

Follow the steps below to measure the voltage on a battery connected to the load.
•  Connect both measuring adapters to the battery that you want to measure. Follow the 

instructions in section "a) Connecting the connecting the contacts to the battery/batteries" 

to establish the connection.

• 

Connect the measuring adapters to a compatible multimeter, as shown in figure 2.

•  Take the measurement. For instructions, refer to the instruction manual that came with your 

measuring device.

c) Measuring current

The diagram below shows how to connect the adapter to a multimeter or other similar 

measurement device. The measurement device is not included and must be purchased 

separately.

Fig.3

Follow the steps below to measure the current on a battery connected to the load.
•  Connect a measuring adapter to the positive terminal on the battery/batteries that you want 

to measure. Follow the instructions in section "a) Connecting the connecting the contacts to 

the battery/batteries" to establish the connection. Ensure that you only use one measuring 

adapter when measuring current.

•  Connect the measuring adapter on the positive battery terminal to a compatible multimeter, 

as shown in figure 3.

•  Take the measurement. For instructions, refer to the instruction manual that came with your 

measuring device.

d)  Measuring voltage and current

Fig.4

Two multimeters are required to measure the voltage and current on a battery connected to the 

load. Follow the steps below to take a measurement.
•  Connect the measuring adapter to the battery that you want to measure. Follow the 

instructions in section "a) Connecting the connecting the contacts to the battery/batteries" to 

establish the connection. In addition to two multimeters, you will also require a second and 

third measuring adapter.

•  Connect the three measuring adapters to two compatible multimeters, as shown in the 

diagram.

•  Take the measurement. For instructions, refer to the instruction manual that came with your 

measuring devices.

e) 9 V block batteries without a battery connector

Block batteries are often connected to devices with a battery connector. However, some devices 

require the battery to be connected to spring-loaded contacts in the battery compartment 

without using a battery connector. If the device requires the block battery to be connected via a 

battery connector, use suitable measuring adapters.

Fig.5

Fig. 6

To measure the voltage (fig. 5) and current (fig. 6) on a block battery connected to the load, 

follow the steps below.
•  Connect the measuring adapter to the block battery that you want to measure. Follow the 

instructions in section "a) Connecting the contacts to the battery/batteries" to establish the 

connection. In this example, round batteries are used, but the principle remains the same 

(insert the contact tabs between the battery and contacts in the battery compartment).

•  To measure the voltage, connect the two measuring adapters to a compatible multimeter, as 

shown in figure 5.

•  To measure the current, connect a measuring adapter to a second compatible multimeter, 

as shown in figure 6.

•  Measure the voltage or current. For instructions, refer to the instruction manual that came 

with your measuring device.

Care and cleaning

•  Always disconnect the product from the power supply before cleaning it. 
•  Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may 

damage the casing or cause the product to malfunction.

•  Use a dry, lint-free cloth to clean the product.

Disposal

  Electronic  devices  are  recyclable  waste  and  must  not  be  placed  in  household 

waste. At the end of its service life, dispose of the product according to the relevant 

statutory regulations.

You thus fulfil your statutory obligations and contribute to protection of the environment.

Technical data

Operating voltage/current ............. <12 V/DC, <1 A
Operating altitude .........................

0–2000 m

Operating conditions .....................

 0 to +40 °C, >5 % relative humidity (non-condensing)

Storage conditions ........................

 -10 to +50 °C, >5 % relative humidity (non-condensing)

Dimensions (L x W x H)

 ................

750 x 13 x 6 mm

Weight ..........................................

35.5 g

Summary of Contents for MB-701

Page 1: ...Messadapter Eine Verwendung ist nur in geschlossenen R umen also nicht im Freien erlaubt Der Kontakt mit Feuchtigkeit z B im Badezimmer u ist unbedingt zu vermeiden Aus Sicherheitsgr nden d rfen Sie...

Page 2: ...schnitt a Kontakte an die Batterie n anschlie en beschrieben Sie ben tigen in diesem Fall neben den zwei Multimetern auch noch einen zweiten und dritten Messadapter Verbinden Sie die drei Messadapter...

Page 3: ...mage the product In addition improper use can cause hazards such as a short circuit or fire Read the instructions carefully and store them in a safe place Only make this product available to third par...

Page 4: ...t you want to measure Follow the instructions in section a Connecting the connecting the contacts to the battery batteries to establish the connection In addition to two multimeters you will also requ...

Page 5: ...interdite Tout contact avec l humidit par ex dans une salle de bain est viter absolument Pour des raisons de s curit toute transformation et ou modification du produit est interdite Si vous utilisez...

Page 6: ...a ou les pile s En plus des deux multim tres vous avez dans ce cas galement besoin d un deuxi me et troisi me adaptateur de mesure Raccordez les trois adaptateurs de mesure deux multim tres appropri s...

Page 7: ...kamers e d dient absoluut te worden vermeden Om veiligheidsredenen zijn er geen aanpassingen en of wijzigingen aan dit product toegestaan Als het product voor andere doeleinden wordt gebruikt dan de h...

Page 8: ...acten aan de batterij en aansluiten In dit geval heeft u naast de twee multimeters ook nog een tweede en derde meetadapter nodig Verbind de drie meetadapters overeenkomstig de afbeelding met twee gesc...

Reviews: