VOLTCRAFT IRF260-10S Operating Instructions Manual Download Page 3

 

If it is no longer possible to operate the product safely, take it out of operation and protect 

it from any accidental use. DO NOT attempt to repair the product yourself. Safe operation 

can no longer be guaranteed if the product:

 

– is visibly damaged,

 

– is no longer working properly,

 

– has been stored for extended periods in poor ambient conditions or

 

– has been subjected to any serious transport-related stresses.

6.5 (Rechargeable) batteries

 

Correct polarity must be observed while inserting the (rechargeable) batteries.

 

The (rechargeable) batteries should be removed from the device if it is not used for a long 

period of time to avoid damage through leaking. Leaking or damaged (rechargeable) bat-

teries might cause acid burns when in contact with skin, therefore use suitable protective 

gloves to handle corrupted (rechargeable) batteries.

 

(Rechargeable) batteries must be kept out of reach of children. Do not leave (rechargeable) 

batteries lying around, as there is risk, that children or pets swallow them.

 

All (rechargeable) batteries should be replaced at the same time. Mixing old and new (re-

chargeable) batteries in the device can lead to (rechargeable) battery leakage and device 

damage.

 

(Rechargeable) batteries must not be dismantled, short-circuited or thrown into fire. Never 

recharge nonrechargeable batteries. There is a risk of explosion!

6.6 Laser

 

When operating the laser equipment, always make sure that the laser beam is directed so 

that no one is in the projection area and that unintentionally reflected beams (e.g., from 

reflective objects) cannot be directed into areas where people are present.

 

Laser radiation can be dangerous, if the laser beam or its reflection enters unprotected 

eyes. Therefore, before using the laser equipment, familiarise yourself with the statutory 

regulations and instructions for operating such a laser device.

 

Never look into the laser beam and never point it at people or animals. Laser radiation can 

seriously damage your eyes.

 

If laser radiation enters your eyes, close your eyes immediately and move your head away 

from the beam.

 

If your eyes have been irritated by laser radiation, do not continue to carry out tasks with 

safety implications, such as working with machines, working from great heights or close to 

high voltage. Also, do not operate any vehicles until the irritation has completely subsided. 

 

Do not point the laser beam at mirrors or other reflective surfaces. The uncontrolled, re

-

flected beam may strike people or animals.

 

Never open the device. Setting or maintenance tasks must only be executed by a trained 

specialist familiar with potential hazards. Improperly executed adjustments might result in 

dangerous laser radiation. 

 

The product is equipped with a class 2 laser. Laser signs in different languages are in-

cluded in the package. If the sign on the laser is not written in the language of your country, 

please affix the appropriate sign onto the laser.

 

 

Caution: if operation settings or procedures other than those described in these instructions 

are used, it could lead to exposure to dangerous radiation.

7 Product overview

0,5 

°C

2,5 

°C

5 °C

1

2

3

4

5

6

7
8

9

10

11

1  Indicator light 
2  LC display 
3  Laser button
4  “SET/REF/°C/°F” button
5  Slide control for indicator value
6  Button for LC display lighting

7  Laser
8  IR sensor
9  On/off/HOLD button
10 Battery compartment
11 Cover for battery compartment

 Operating Instructions

IR thermal leak detector IRF260-10S

Item No. 631768

1 Intended use

The infrared thermal leak detector is used for quick inspection of thermal leaks and thermal 

bridges. The measurement device warns you optically and acoustically when approaching the 

set limits.
Power is supplied by a 9 V block battery.
The measuring instrument must not be used when it is open, i.e. with an open battery compart-

ment or when the battery compartment cover is missing. Measuring under adverse ambient 

conditions such as dust and flammable gasses, vapours or solvents is not admissible.

If you use the product for purposes other than those described, the product may be damaged. 

Improper use can result in short circuits, fires, electric shocks or other hazards.

The product complies with the statutory national and European requirements. For safety and 

approval purposes, you must not rebuild and/or modify the product.
Read the operating instructions carefully and store them in a safe place. Make this product 

available to third parties only together with the operating instructions.
All company names and product names are trademarks of their respective owners. All rights 

reserved.

2 Delivery content

 

IR thermal leak detector

 

9 V block battery

 

Operating instructions

3 Latest product information

Download the latest product information at 

www.conrad.com/downloads

 or scan the QR code 

shown. Follow the instructions on the website.

4 Symbols in this document

The symbol warns of hazards that can lead to personal injury. Read the information 

carefully.

The arrow symbol indicates special information and advice on operation.

5 Symbols on the product

Laser radiation. Never look into the laser beam and never point it at people or ani-

mals.

6 Safety instructions

Read the operating instructions carefully and especially observe the safety 

information. If you do not follow the safety instructions and information on 

proper handling in this manual, we assume no liability for any resulting per-

sonal injury or damage to property. Such cases will invalidate the warranty/

guarantee.

6.1 General information

 

The device is not a toy. Keep it out of the reach of children and pets.

 

Do not leave packaging material lying around carelessly. This may become dangerous 

playing material for children.

 

If you have questions which remain unanswered by these operating instructions, contact 

our technical support service or other technical personnel.

 

Maintenance, modifications and repairs must only be completed by a technician or an au

-

thorised repair centre.

6.2 Handling

 

Please handle the product carefully. Jolts, impacts or a fall even from a low height can 

damage the product.

6.3 Operating environment

 

Do not place the product under any mechanical stress.

 

Protect the appliance from extreme temperatures, strong jolts, flammable gases, steam 

and solvents.

 

Protect the product from high humidity and moisture.

 

Protect the product from direct sunlight.

 

Do not switch the product on after it has been taken from a cold to a warm environment. 

The condensation that forms might destroy the product. Allow the product to reach room 

temperature before you use it.

6.4 Operation

 

Consult an expert when in doubt about the operation, safety or connection of the appliance.

Summary of Contents for IRF260-10S

Page 1: ...er dient zur schnellen Kontrolle von Temperaturlecks und Kältebrücken Das Messgerät warnt Sie beim Annähern der eingestellten Grenzwerte optisch und akustisch Die Spannungsversorgung erfolgt über eine 9 V Blockbatterie Das Messgerät darf im geöffneten Zustand mit geöffnetem Batteriefach bzw bei fehlendem Batteriefach deckel nicht betrieben werden Messungen unter widrigen Umgebungsbedingun gen wie ...

Page 2: ... Be darf ein oder ausgeschaltet werden Zum Einschalten drücken Sie einmal kurz die Taste 6 Das LC Display leuchtet Zum Ausschalten der Beleuchtung drücken Sie erneut einmal kurz die Taste 6 9 6 3 Referenzwert fixieren Während dem Messvorgang wird Ihnen im LC Display der aktuelle Temperatur Referenzwert B angezeigt Dieser Wert wird stetig angepasst Um den Wert für diesen Messvorgang zu fixieren drü...

Page 3: ... for indicator value 6 Button for LC display lighting 7 Laser 8 IR sensor 9 On off HOLD button 10 Battery compartment 11 Cover for battery compartment Operating Instructions IR thermal leak detector IRF260 10S Item No 631768 1 Intended use The infrared thermal leak detector is used for quick inspection of thermal leaks and thermal bridges The measurement device warns you optically and acoustically...

Page 4: ...2 Display light For better readability the measuring device features an LC display lighting This lighting can be switched on or off as required Briefly press the button 6 to switch it on The LC display lights up To switch off the lighting briefly press the button 6 once again 9 6 3 Fixing the reference value During the measurement the current temperature reference value B is shown on the LC dis pl...

Page 5: ...uites thermiques sert à contrôler rapidement les fuites thermiques et les ponts thermiques L appareil de mesure vous avertit de manière visuelle et sonore lorsque l on approche les valeurs limites prédéfinies L alimentation électrique s effectue avec une pile bloc de 9 volts L appareil de mesure ne doit pas être utilisé lorsqu il est ouvert ni lorsque le couvercle du logement des piles est ouvert ...

Page 6: ...r la mise en marche appuyer brièvement sur la touche 6 L écran LC est éclairé Pour désactiver l éclairage appuyer de nouveau brièvement sur la touche 6 9 6 3 Fixer la valeur de référence Pendant la mesure l écran LC afficher la valeur de référence actuelle de la température B Cette valeur est constamment adaptée Pour fixer la valeur pour cette opération de mesure appuyer une fois brièvement sur la...

Page 7: ...zoeker dient voor de snelle controle van temperatuurlekken en koudebruggen Het meetapparaat waarschuwt optisch en akoestisch bij het benaderen van de ingestelde grenswaarden Stroom wordt voorzien door een 9 V blokbatterij Gebruik het meetapparaat niet in geopende toestand met geopend batterijvak resp bij ont brekend klepje van het batterijvak Metingen bij ongunstige omgevingsomstandigheden zoals b...

Page 8: ...toets 6 De LC Display wordt verlicht Om de verlichting te deactiveren drukt u opnieuw eenmaal kort op de toets 6 9 6 3 Referentiewaarde vastzetten Tijdens de meting wordt in de LC Display de actuele temperatuurrefentiewaarde B getoond Deze waarde wordt steeds aangepast Druk eenmaal kort op de toets SET REF C F om de waarde voor deze meting vast te zetten De vastgezette referentiewaarde B wordt in ...

Reviews: