background image

Quick Guide 

 

Quick Guide 

Front Panel   

8

2

5

3

7

4

6

1

 

1.

 

Display area 

2.

 

Control (button and knob) area 

3.

 

Probe Compensation: Measurement signal (5V/1kHz) output.   

4.

 

EXT Trigger Input 

5.

 

Signal Input Channel 

6.

 

Copy button: You can save the waveform by just pressing this  button in any  user 

interface. 

7.

 

USB Host port:

 It is used to transfer data when external USB equipment connects to 

the oscilloscope regarded as "host device".

 

For example: Saving the waveform to USB 

flash disk needs to use this port. 

8.

 

Power on/off 
Backlight of this button:   

Red light: 

The oscilloscope is turned off (connects with AC Power); 

Green light:

 The oscilloscope is turned on. 

Summary of Contents for DSO-6202F

Page 1: ... can save the waveform by just pressing this button in any user interface 7 USB Host port It is used to transfer data when external USB equipment connects to the oscilloscope regarded as host device For example Saving the waveform to USB flash disk needs to use this port 8 Power on off Backlight of this button Red light The oscilloscope is turned off connects with AC Power Green light The oscillos...

Page 2: ...cts to the oscilloscope regarded as slave device For example to use this port when connect PC to the oscilloscope by USB 9 Lock Hole You can lock the oscilloscope to a fixed location using the security lock please buy it yourself to secure the oscilloscope 10 Trig Out P F port Trigger signal output or Pass Fail output also can be used as the port of CH2 Output of optional dual channel waveform gen...

Page 3: ...orizontal Scale control time base 5 Vertical control area with 3 buttons and 4 knobs CH1 and CH2 correspond to setting menu in CH1 and CH2 Math button provides access to math waveform functions FFT user function digital filter Two Vertical Position knob control the vertical position of CH1 CH2 and two Scale knob control voltage scale of CH1 CH2 6 Default Call out the factory settings 7 Print Print...

Page 4: ...e waveform Ready Pre triggered data captured and ready for a trigger Scan Capture and display the waveform continuously Stop Data acquisition stopped 4 Click to show hide the touchable menu pane 5 Turn on off the magnifier function 6 The two blue dotted lines indicates the vertical position of cursor measurement 7 The T pointer indicates the horizontal position for the trigger 8 The pointer indica...

Page 5: ...count E the Rise edge count E the Fall edge count AR the Area CA the Cycle area 19 The icon shows the selected trigger type e g represents triggering on the rising edge for an Edge trigger The reading shows the trigger level value of the corresponding channel 20 Channel identifier of current bottom menu 21 The readings show the record length 22 The frequency of the trigger signal 23 The readings s...

Page 6: ... DC gain accuracy 1 mV 3 2 mV 2 5 mV 1 5 Vertical sensitivity 1 mV div 10 V div Trigger type Edge Video Pulse Slope Runt Windows Timeout Nth Edge Logic I2C SPI RS232 CAN Decoding Type RS232 I2C SPI CAN Trigger mode Auto Normal Single Line field frequency Video Support standard NTSC PAL and SECAM broadcast systems Automatic measurement Period Frequency Mean PK PK RMS Max Min Top Base Amplitude Over...

Page 7: ... and Pulse Multimeter Optional Full scale reading 3 digits Max 4000 count Diode 0 V 1 5 V Input impedance 10 MΩ On Off measurement 50 30 Ω beeping Capacitance 51 2nF 100uF 3 3 digit Voltage DCV 400mV 4V 400V 1 1digit Max input DC 1000V ACV 4V 40V 400V 1 3digit Frequency 40Hz 400Hz Max input AC 750V virtual value Current DCA 40mA 400mA 1 5 1 digit 10A 3 3digit ACA 40mA 1 5 3 digit 400mA 2 1 digit 1...

Reviews: