![VOLTCRAFT 2576866 Operating Instructions Manual Download Page 91](http://html1.mh-extra.com/html/voltcraft/2576866/2576866_operating-instructions-manual_1047231091.webp)
91
TrueRMS peak for non-sinusoidal signals plus tolerance:
CF >1.0 - 2.0 + 3%
CF >2.0 - 2.5 + 5%
CF >2.5 - 3.0 + 7%
Low impedance measurement (LoZ)
Range
Resolution
Accuracy
6 - 1000 V
0.1 V
±(2% + 3)
DC or 45 Hz - 1 kHz
1000 V overload protection; impedance: 400 KΩ
Mixed voltage V/AC+DC
Range
Resolution
Accuracy
6.0000 V
0.0001 V
45 Hz - 1 kHz ±(0.8% + 70)
>1 kHz - 10 kHz ±(2.4% + 70)
>10 kHz - 35 kHz ±(5% + 70)
60.000 V
0.001 V
45 Hz - 1 kHz ±(0.8% + 70)
>1 kHz - 10 kHz ±(2.4% + 70)
>10 kHz - 35 kHz ±(5% + 70)
600.00 V
0.01 V
45 Hz - 1 kHz ±(0.8% + 70)
>1 kHz - 10 kHz ±(2.4% + 70)
>10 kHz - 35 kHz not specified
1000.0 V
0.1 V
45 Hz - 1 kHz ±(0.8% + 70)
>1 kHz - 10 kHz ±(2.4% + 70)
>10 kHz - 35 kHz not specified