VOLTCRAFT 122485 Brief Instructions Download Page 3

  

BRIEF INSTRUCTIONS

VERSION 07/14

DIGITAL OSCILLOSCOPE

ITEM NO.:  122485    DSO-1062D

ITEM NO.:  1009672  DSO-1102D

ITEM NO.:  1009673  DSO-1202D

ITEM NO.:  1182186  DSO-1062D-VGA

INTENDED USE

The digital oscilloscope is intended to be used for visualising electrical magnitudes and signals. For 

measurement, 2 mutually independent input channels are available for analogue signals. The sensing 

heads are connected to the oscilloscope via BNC connectors. 2 sensing heads are enclosed.
The measured signals can be stored and displayed as a reference. The oscilloscope can be connected to a 

computer via the USB interface for evaluation and control. Depending on the model, there is an additional 

VGA port available for connecting an external monitor.
The control of the device is performed via VDU-based control menus.
The maximum measuring voltage indicated on the device (300 VRMS (eff.)) must never be exceeded. Use 

divider probes if necessary.
The device should be connected to and operated with an earthed socket of the public mains supply only.
Any use other than that described above could lead to damage to this product and involves the risk of short 

circuits, fire, electric shock, etc.
The product must not be changed or modified in any way. Do not open the housing.

Measurements are not permitted in damp rooms or outdoors, nor under adverse environmental conditions.
Unfavourable ambient conditions are:

 - Wetness or high air humidity,
 - Dust and combustible gases, vapours or solvents,
 -

Thunderstorms or similar conditions such as strong electrostatic fields, etc.

Always observe the safety notes included in these operating instructions.
This quick guide explains the safety measures that should be taken to make working with the device as 

safe as possible. The individual functions are described in more detail in the English operating instructions 

manual. It is located in the main directory in the attached CD. A Help menu is integrated additionally in the 

Oscilloscope (“HELP” button).

EXPLANATION OF THE SYMBOLS

This device left the manufacturer’s factory in a safe and perfect condition.
We kindly request that the user observes the safety instructions and warnings contained in the enclosed 

operating instructions so this condition is maintained and to ensure safe operation. Please pay attention to 

the following symbols:

A triangle containing an exclamation mark indicates important information in these operating 

instructions that is to be observed without fail.

A lightning symbol in a triangle warns against an electric shock or impairment of the electrical 

safety of the device.

The “arrow” symbol indicates where special tips and notes on operations are provided.

This product has been CE-tested and meets the required European guidelines. Warning! This is a 

class A device. It can cause radio interferences in residential areas; in this case, it can be 

demanded that the operator carries out appropriate measures.

Voltage surge category I for measurements on signal and control voltages without powerful 

discharges.
Voltage surge category II for measurements on electric devices connected to the mains supply by 

a power plug. This category also covers all smaller categories (e.g. CAT I for measuring signal 

and control voltages).
Protective conductor connection, safety class 1. This screw/this connection must not be 

detached.

Earth potential

Reference earth chassis

Measurement input (internal/external conductor)

Operating switch: Pressed = I = ON; not pressed = 0 = OFF

SAFETY INSTRUCTIONS AND HAZARD WARNINGS

Please read all the instructions before using this device; they contain important 

information on its correct operation.

The warranty will be void in the event of damage caused by failure to observe these safety instructions! We 

do not assume any liability for any subsequent damage!
We shall not accept liability for damage to property or personal injury caused by incorrect handling or 

noncompliance with the safety instructions! Any warranty will be void in such cases.

The unauthorised conversion and/or modification of the product is not allowed for safety and approval 

reasons (CE).
The design of the product complies with the safety class 1. Use only a domestic mains socket (100 – 

240 V~) of the public power supply network to power the unit.
Measuring devices and devices connected to the power supply should be kept out of the reach of children. 

Therefore, be especially careful when children are around.
First, connect the BNC output of the measurement cable to the oscilloscope; then connect the probe to 

the electric circuit to be measured. When the measuring is completed, please disconnect the measuring 

contacts first before disconnecting the BNC output of the probe from the oscilloscope.

Be especially careful when dealing with voltages higher than > 50 V alternating current (AC) or > 75 V 

direct current (DC)! Even at such voltages you can get a life-threatening electric shock if you come into 

contact with live electric wires.
Check the measuring device and its measuring leads for any damage before each measurement. Never 

take any measurements if the protecting insulation is defective (torn, missing etc.).
To avoid electric shock, do not touch the connections/measuring points directly or indirectly during 

measurements.
Never reach beyond the grip surface of the probes during a measurement process. There is danger of a 

life-threatening electric shock.
Do not use the device shortly before or after a thunderstorm (lightning! / high-power surges!). Make sure 

that your hands, shoes, clothing, the floor, the measuring device and/or measuring lines, the circuits and its 

parts are always dry.
Do not use the device in rooms or under unfavourable ambient conditions in which there are or could be 

combustible gases, vapours or dust.
Do not use in the immediate vicinity of:

 -

strong magnetic or electromagnetic fields

 - transmitting aerials or HF generators.

These can affect the measurement.

Use only measurement lines and accessories for the measurement that match the specifications of the 

oscilloscope.
If a safe operation can no longer be assumed, the device must be put out of operation and secured against 

unintended operation. Safe operation can no longer be assumed if:

 - the device is visibly damaged,
 - the device does not function any more and
 - the device has been stored under unfavourable conditions for a long period of time or
 - it has been subjected to considerable stress during transportation.

Never switch the device on immediately after having taken it from a cold to a warm environment. The 

condensation that forms might destroy your device. Allow the device to reach room temperature before 

switching it on.
Never disassemble the product! There is danger of a life-threatening electric shock!
Do not carelessly leave the packaging material lying around, since it could become a dangerous plaything 

for children.
The device is intended only for dry interior rooms (not bathrooms or similar damp rooms). The device must 

not get wet or damp. There is danger of a life-threatening electric shock!
On industrial sites, the accident prevention regulations of the association of the industrial workers’ society 

for electrical equipment and utilities must be followed.
Measurement instruments used at schools, training facilities, do-it-yourself and hobby workshops should 

not be handled unless supervised by trained, responsible personnel.
If you have doubts about how the equipment should be operated or how to connect it safely, consult a 

trained technician.
Handle the product with care. It can be damaged through impact, blows, or accidental drops, even from a 

low height.
Please also note the enclosed detailed operating instructions.

Regularly check the technical safety of the device and the measuring lines, e.g. for 

damage of the housing or crushing, etc. Never operate the device when it is open. !RISK 

OF FATAL INJURY!
Never exceed the maximum admissible input values. Never touch circuits or parts of 

circuits with voltages greater than 50 V/AC rms or 75 V/DC! Life threatening!

UNPACKING

Check all the parts for completeness and damage after unpacking.

Damaged parts must not be used for safety reasons. In case of any damage contact our 

customer service.

PACKAGE CONTENTS

•  Digital memory oscilloscope
•  Two sensing heads with accessories
•  Cable with earthing contact
•  USB cable
•  CD with driver, software and extensive GB operating instructions manual
•  Quick guide

Summary of Contents for 122485

Page 1: ...der Schutzklasse 1 Als Spannungsquelle darf nur eine ordnungsgemäße geerdete Netzsteckdose 100 240 V des öffentlichen Strom Versorgungsnetzes verwendet werden Messgeräte und Geräte die an Netzspannung betrieben werden gehören nicht in Kinderhände Lassen Sie deshalb in Anwesenheit von Kindern besondere Vorsicht walten Schließen Sie den BNC Ausgang des Messkabels zuerst an das Oszilloskop an bevor S...

Page 2: ...k ANSCHLUSS UND INSTALLATION DES DSO Verbinden Sie das beiliegende USB Anschlusskabel mit einem freien USB Port an Ihrem Computer und anschließend mit dem rückseitigen USB Anschluss am DSO Das Betriebssystem erkennt eine neue Hardware und startet den Hardware Assistenten Das System sucht automatisch nach den passenden Treibern und installiert diese Das Gerät sollte nun verwendet werden können Fall...

Page 3: ...ns CE The design of the product complies with the safety class 1 Use only a domestic mains socket 100 240 V of the public power supply network to power the unit Measuring devices and devices connected to the power supply should be kept out of the reach of children Therefore be especially careful when children are around First connect the BNC output of the measurement cable to the oscilloscope then...

Page 4: ... for device installation CONNECTION AND INSTALLATION OF THE DSO Connect the provided USB connection cable to a free USB port on your computer and then with the USB connection on the back of the DSO The operating system recognises the new hardware and starts the Hardware Wizard The system automatically searches for the suitable drivers and installs them You should now be able to use the device If t...

Page 5: ...truction de l appareil correspond à la classe de protection 1 Comme source de tension utilisez uniquement une prise électrique en état de fonctionnement 100 240 V et raccordée au réseau d alimentation public Maintenez les instruments de mesure et les appareils fonctionnant sous tension hors de la portée des enfants Soyez particulièrement vigilant lors du fonctionnement en présence d enfants Connec...

Page 6: ...nu de démarrage un nouveau dossier DSO XXXX est créé Laissez le CD pour l installation de l appareil dans le lecteur RACCORDEMENT ET INSTALLATION DE L OSCILLOSCOPE Connectez le câble USB à un port USB libre de votre ordinateur et ensuite au port USB à l arrière de l oscilloscope en vous servant du câble de raccordement USB fourni Le système d exploitation reconnaît un nouveau matériel et lance l a...

Page 7: ...ueerd Als spanningsbron mag alleen een wandcontactdoos 100 240 V van het openbare stroomnet worden gebruikt die aan de voorschriften voldoet Meetapparatuur en apparaten die op het lichtnet aangesloten worden moeten buiten het bereik van kinderen gehouden worden Wees daarom extra voorzichtig als er kinderen aanwezig zijn Sluit de BNC uitgang van de meetkabel eerst op de oscilloscoop aan voordat u d...

Page 8: ...verde USB aansluitkabel aan op een vrije USB poort van uw computer en vervolgens op de aan de achterkant aanwezige USB aansluiting op de DSO Het besturingssysteem herkent de nieuwe hardware en start de Hardware assistent Het systeem zoekt automatisch naar de geschikte stuurprogramma s en installeert deze Het apparaat moet nu gebruikt kunnen worden Indien deze informatie verschijnt De software van ...