![VOLTA V-385 Instruction Manual Download Page 5](http://html1.mh-extra.com/html/volta/v-385/v-385_instruction-manual_1046434005.webp)
(2) Power Indicator
(06)
(displays power output level)
Power LED
OFF
GREEN
ORANGE
RED
RED, blinking
Output Power (LP450x)
0~35W
35W~200W
200W~350W
350W~460W
>460W
Output Power (V-385)
0~35W
35W~230W
230W~520W
520W~670W
>670W
(3) Status Indicator
(07)
(displays working status)
Status LED
RED
GREEN
Working Status
No
Yes
2.2 Mode Selection
(15)
The inverter is designed with two operating modes: “Normal” (non-flash mode) and “Flash” (flash
mode). Users can choose either operating mode depending on the equipment
being powered
.
The “Flash” (flash mode) is specially designed for the use with monolights.
in this
mode
power saving function is not available so the built-in battery can stand by for only 13
hours.
In “Normal” (non-flash mode), the use of
not available. In this mode
power saving function
the built-in battery stand by for 55 hours. Therefore,
non-flash electronics are recommended to use this mode.
For details, refer to Section VI “Introduction to Function Mode”.
2.3
Power
Switch (04)
“OFF”: The inverter is powered off.
“ON”: The inverter is powered on
“USB”: The inverter enters into USB charging mode. ortable electronics with USB interfaces
such as iPhone iPad
can be charged from the USB
sockets. In USB mode, no AC power output is available.
USB1: Output 5V/2000mA
USB2: Output 5V/1000mA
USB3: Output 5V/500mA
2.4 AC Output Socket (02)
●
Three AC output sockets are in parallel connection, and each of them can output the maximum
power.
●
The
sockets are universal and accepts most foreign power cords. No adapter is required.
●
tandard voltage 120V/60Hz
depending on the model you purchase.
IV. Operation Instruction
1. Installation and Detachment of Battery Unit
●
Installation
1. Place the control unit on the battery unit so that the control unit
power
2.
the units together.
●
Detachment
1. Push the button on each locking clasp to open the four locking
clasps.
2. Remove the control unit from the battery unit.
1.1 Charging
The AC charger
.
1.
Turn the inverter off before charging.
2.
Insert the “Charging Connection Cable (25)” of the charger into
the “Charging Socket (17)” on the inverter.
3.
Insert the “AC Output Plug (28)”of the Charger Power Cable into
the “AC Input Socket (24)”of the charger, and connect the “AC
Input Plug (27)” to any AC power for charging.
This battery unit can be charged using AC power supply (100-240V). However, an
adapter may be needed when charging the inverter in different countries.
1.2 LED Lamps of the Charger
(1) The red lamp is blinking:
.
(2) The red lamp is lit continuously:
harging.
(3) The green lamp is lit: Charging is complete.
It takes about 6 hours to fully charge the inverter when the battery power is empty.
Ensure to pull out the “Charging Connection Cable” when the charging is complete. To
maintain the expected service life of the battery, ensure to fully charge the inverter in
the following circumstances:
●
Each time after using the VOLTA Inverter.
●
Before using the inverter if it has not been used in more than 100 days.