10
4.4 General Data
Model
1KTS
1.5KTS
2KTS
3KTS
4KTS
5KTS
6KTS
7KTS
Dimension (W/H/D)
288*350*140[mm]
338*430*138[mm]
345/440/186[mm]
Weight [kg]
11
11.5
13.5
15.5
2
1
21.5
22
2
3
Cooling concept
Convection
Convection
Convection
Convection Fan
Fan
Fan
Fan
Noise (typical) [dB]
<28
<28
<30
<30
<30
<40
<40
<40
Operating
temperature range
[°C]
-20 °C
~
+60 (de-rating at 45 °C)
Degree of protection
IP65
Topology
Transformer less
Internal consum-
ption( night ) [W]
0
LCD display
Backlight, 16*2 character LCD
Communication
interfaces
RS232
RS485 / RS232
Standard warranty
5 years
5. Function
Operation Mode
【
standby Mode
】
The standby mode means that the inverter is ready for operation but still not connected to the grid. In this mode, it
will continue to check whether PV array has enough power to feedback into grid. When the inverter passes dump
load test after startup, it will change from standby mode to Checking mode.
【
Checking Mode
】
If inverter passes dump load test and no error/fault occurs, will start checking mode to deliver power.
【
On-grid Mode
】
In this mode, series inverters convert PV array’s DC into AC and feedback into grid.