Wedgemaster II Ops Manual
4
BLADE SERVICING AND REPLACEMENT
If the machine no longer slices cleanly or without damage, the blades could be dull and need to be replaced.
Broken, bent, nicked, or dull blades must be replaced immediately. Change the complete assembly.
1. Allow yourself ample room to work on a flat, dry surface.
2. Turn machine on its side and remove the Pusher Head Assembly.
3. Remove the two (2) Blade Screws from the bottom of the Base Assembly. Carefully remove the blade
assembly by gently pushing up from underneath the Base Assembly. This will remove the blade assembly
from the unit.
4. Install new blade assembly by carefully placing it inside the top of the Base Assembly. NEVER push down
on blade assembly when inserting into the base! Once in place, insert the two (2) blade screws until tight.
DISPOSE OF USED BLADES AND BLADE ASSEMBLIES!
!
DANGER:
HANDLE WITH EXTREME CARE AS BLADES ARE SHARP AND CAN CAUSE
INJURY OR DEATH IF NOT HANDLED PROPERLY. ALL OPERATORS OF
THIS EQUIPMENT SHOULD READ THIS OPERATION MANUAL BEFORE
OPERATING EQUIPMENT.
!
CAUTION:
PRIOR TO USING YOUR NEW EQUIPMENT, IT IS IMPORTANT TO CLEAN
THE UNIT. WASH NEW BLADES WITH WARM SOAPY WATER AND RINSE
THOROUGHLY TO REMOVE THE THIN PROTECTIVE OIL FILM.