background image

C

ountertop

 C

ooking

 e

quipment

 

3

ENGLISH

O

peratOr

s

 M

anual

f

eatUres

 

and

 c

ontrols

E

H

B

A

C

F

D

E

G

Figure 1. Features and Controls

A

  THERMOSTAT CONTROL dial. Used to set or adjust the 

temperature of the well. The numbers on the dial correspond 

with the oil temperature. The “0” position is off.

B

  OVER TEMPERATURE RESET SWITCH and COVER. 

Remove cover to access the reset switch. If the oil reaches a 

temperature of 430°F (221°C) this switch cuts power to the unit.

C

  HIGH OIL LEVEL. This is the maximum level mark for the well. 

Do not ill with oil above this mark because it may cause oil to 

overlow the well after the basket of food has been added.

D

  LOW OIL LEVEL. This is the minimum level mark for the well. 

Do not operate with oil below this level as the oil may overheat 

and start a ire.

E

  LIFTING HANDLES. Used to lift the well in and out of the unit 

for oil disposal and cleaning.

F

  WELL. Holds the oil and is where the cooking takes place. A 

heating element is suspended in this component.

G

  HEATING ELEMENT. This is what heats the oil or lard.

H

  PILOT LIGHT. This light indicating that the element is heating. 

Once the temperature has been reached the light will go out. 

Unit will continue to maintain heat and temperature with light 

cycling on and off. This is not an “ON/OFF” light.

o

peration

 

Follow these same instructions for each well of a two well unit. Each well 

operates independently and may be operated a different temperatures.

1.  Remove basket(s) from fryer.

2.  Fill or add oil/solid shorting to the well (F). Always maintain oil level 

between High Oil Level (C) and Low Oil Level (D) as indicated on the 

side of the well. See Figure 1. DO NOT overill. 

 

WARNING

Burn Hazard.

Do not touch hot liquid or heating surfaces while 

unit is heating or operating.

Hot liquids and food can burn skin. Allow the hot liquid to cool 

before handling. Do not drop or spill water into hot oil as it will spray 

or splatter the hot oil out of the tank. 

WARNING

Fire Hazard.

Overheated oil or oil vapors can ignite causing a 

ire. Monitor oil temperature, quality and level. Use 

and maintain oil vapor removal system. 

Heat oil carefully. If oil smokes, reduce heat. Do not leave unit 

unattended. If ire occurs, turn unit off, cover until cool. Do not 

put water on hot or laming oil. Do not operate with oil below low 

oil mark. Dirty oil has a lower lash point. Replace oil on a regular 

basis. Maintain correct oil level. Use an oil vapor removal system 

(hood) to reduce oil and grease buildup on wall or ceiling surfaces.

3.  Adjust the thermostat control (A) to the desired temperature; the pilot 

light (H) indicates when the elements are energized. If lard or solid type 

oil is used the unit must be pulsed in 1 to 2 minute on and off cycles at 

low-med temperature until liquid covers the heating coils. This will reduce 

smoking and risk of ire.

4.  Allow the unit to preheat and the oil to come up to cooking temperature, 

approximately 15 minutes. The pilot light (H) will cycle when the oil has 

reached the set temperature.

5.  Load each basket; NEVER more that half way full.

6.  Carefully lower the basket into the cooking oil.

7.  When removing the basket from the oil, allow the excess oil to drain back 

into the well before transferring to holding area.

o

il

 t

ips

1.  Use high quality oil.

2.  Cook at temperatures that are recommended by food manufacture.

3.  Change oil as needed or food quality requires.

4.  Skim oil often and ilter daily.

5.  Cover oil overnight.

Total Restaurant Supply - https://totalsupply1.com - Toll Free 1-800-944-9304 - Local 507-288-9454

2940 Hwy 14 W, Rochester, MN 55901

Summary of Contents for 40705

Page 1: ... Description Voltage HZ kW Plug 40705 10 lb Countertop Fryer 120V 50 60 1 8 15 Amps 5 15P 40706 10 lb Countertop Fryer 220V 50 60 2 5 11 3 Amps 6 15P 40707 20 lb Countertop Fryer 120V 50 60 2 x 1 8 2 x 15 Amps 2 x 5 15P 40708 20 lb Countertop Fryer 220V 50 60 2 x 2 5 2 x 11 3 Amps 2 x 6 15P One 1 dedicated 20 Amp circuit with a single outlet is required for each fryer head Two separate dedicated 2...

Page 2: ...c burners or excessive heat 9 Use only grounded electrical outlets matching the nameplate rated voltage 10 Do not use an extension cord with this equipment 11 Do not spray controls or outside of unit with liquids or cleaning agents safety precaUtions To ensure safe operation read the following statements and understand their meaning This manual contains safety precautions which are explained below...

Page 3: ...ard Do not touch hot liquid or heating surfaces while unit is heating or operating Hot liquids and food can burn skin Allow the hot liquid to cool before handling Do not drop or spill water into hot oil as it will spray or splatter the hot oil out of the tank WARNING Fire Hazard Overheated oil or oil vapors can ignite causing a ire Monitor oil temperature quality and level Use and maintain oil vap...

Page 4: ...moval system Heat oil carefully If oil smokes reduce heat Do not leave unit unattended If ire occurs turn unit off cover until cool Do not put water on hot or laming oil Do not operate with oil below low oil mark Dirty oil has a lower lash point Replace oil on a regular basis Maintain correct oil level Use an oil vapor removal system hood to reduce oil and grease buildup on wall or ceiling surface...

Page 5: ...ace Thermostat Control Oil heats slowly Low or incorrect voltage to unit Verify that voltage rating in unit matches the source voltage If not have qualiied electrical personnel install proper source voltage Oil boils over top when frying Too much oil in well Reduce the amount of oil in well Too much food in basket Reduce the amount of food in basket Too much water in food Dry food product or remov...

Page 6: ...ensor 11 XFA0011 Micro Switch 12 XFFA0012 Safe Operation Switch 13 N A Back Plate 14 XCOA1013 Power Cord Restraint 15 XAA0005 Power Cord 120V NEMA 5 15P Plug 15 XAA0006 Power Cord 220V NEMA 6 15P Plug 16 N A Element Cover 17 XFFA0002 Heating Element 120V 1800 Watt 17 XFFA0003 Heating Element 220V 2500 Watt 18 FFB1250 Basket Small 19 FFB2250 Basket Large 20 XFEIN001 Fryer Insert 21 N A Hinge Right ...

Page 7: ... 9 17 16 18 19 10 13 11 12 20 25 23 21 24 7 8 6 14 15 22 1 26 26 23 21 21 22 22 eXploded vieW coUntertop fryer models 40705 40706 40707 40708 Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Page 8: ...stat 3 XAA0011 Pilot Light 120V Amber 4 XFA0011 Micro Switch 5 XFFA0002 Heating Element 120V 1800 Watt Wiring diagram models 40706 and 40708 Callout Part Number Description 1 XFFA0009 Safety Thermostat 2 XFFA0008 Temperature Control Thermostat 3 XAA0002 Pilot Light 220V Red 4 XFA0011 Micro Switch 5 XFFA0003 Heating Element 220V 2500 Watt Total Restaurant Supply https totalsupply1 com Toll Free 1 8...

Page 9: ...Countertop Cooking equipment 9 ENGLISH OperatOr s Manual notes Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Page 10: ...RANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE As The Vollrath Company LLC s only responsibility and the purchaser s only remedy for any breach of warranty The Vollrath Company LLC will repair or at its option replace the defective product or part without charge except as otherwise provided below For refrigeration compressors and the second year of the warranty on Cayenne Heat Strips...

Page 11: ...co com NO WEB ACCESS If you do not have access to the web kindly register by completing the warranty registration form and faxing it to The Vollrath Co LLC ofice in the country of purchase Warranty registration business name key ContaCt name email street address City state Zip Code Country phone fax model item number serial number operation type R Limited Service Restaurant R Full Service Restaura...

Page 12: ...3201 U S A Main Tel 800 628 0830 Fax 800 752 5620 Technical Services 800 628 0832 Service Fax 920 459 5462 Canada Service 800 695 8560 2010 The Vollrath Company L L C Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...