This fryer is a medium duty appliance capable of a wide variety of frying 

applications. The temperature is thermostatically controlled between 

120°F (49°C) and 400°F (204°C). The thermostat is also the ON/OFF 

switch. An indicator lamp adjacent to the thermostat dial indicates when 

the elements are heating.

U

npacking

 

the

 e

qUipment

Dispose of all packaging, materials in an environmentally responsible 

manner. 
1.  Remove all packing material and tape, as well as any protective 

plastic from the unit.

2.  Clean any glue residue left over from the plastic or tape.

3.  Place the unit in the desired position and height.

4.  Plug unit into a properly grounded electrical supply matching the 

nameplate rating. Damage to the unit can occur if incorrect power is 

supplied to unit.

i

nstallation

 s

afety

 p

recaUtions

 

WARNING

Fire Hazard.

Correct installation precautions, procedures and 

regulations must be followed. Operation and safety 

training is necessary for all users of this equipment. 

The equipment must be installed by qualiied personal only. 

Correct 

installation precautions, procedures and regulations must be followed in 

order to reduce the risk of ire. Hood and ire suppression systems must 

be maintained per manufacture’s guidelines. Only personnel qualiied 

and trained are to use this equipment.

1.  The fryer must not be installed under combustible materials and the 

minimum clearance from combustible construction must be 6” (15 cm) 

from the sides and back of the fryer. The area surrounding the fryer 

should be kept free and clear of combustible materials.

2.  All deep fryers must be installed with at least 16” (40.6 cm) space 

between the fryer and surface lames from adjacent cooking 

equipment.

3.  Equipment must installed by a qualiied personal in accordance with 

federal, state and local codes.

4.  The fryer should be installed under a hood in accordance with 

the latest edition of the Standard for Ventilation Control and Fire 

Protection of Commercial Cooking Operations, NFPA 96.

5.  Never direct the automatic ire extinguishers so they can blow the oil 

out of the container.

6.  Locate the fryer in a place where it cannot be pushed off counter.

7.  Keep the area at the front of the fryer clear for unobstructed access 

during operation.

8.  Keep unit and power cord away from open lames, electric burners or 

excessive heat.

9.  Use only grounded electrical outlets matching the nameplate rated 

voltage.

10. Do not use an extension cord with this equipment.

11. Do not spray controls or outside of unit with liquids or cleaning agents.

s

afety

 p

recaUtions

To ensure safe operation, read the following statements and 

understand their meaning. This manual contains safety precautions 

which are explained below. Please read carefully.

  

WARNING

Warning is used to indicate the presence of a hazard that 

can

 cause 

severe

 personal injury, death, or substantial property damage if the 

warning is ignored.

  

CAUTION

Caution is used to indicate the presence of a hazard that 

will

 or 

can

 

cause 

minor

 personal injury or property damage if the caution is 

ignored.

NOTE

Note is used to notify people of installation, operation, or 

maintenance information that is important but not hazard-related.

For Your Safety!

These precautions should be followed at all times. Failure to follow 

these precautions could result in injury to yourself and others.

To reduce risk of injury or damage to the unit:
1.  Do not operate unattended. 

2.  Unit must be only used in a lat, level position.

3.  Change oil regularly or as necessary. Old or dirty oil has a lower lash 

point than clean oil.

4.  Fill to correct level with oil. Do not over ill.

5.  Do not overill basket. Do not ill basket more than half full. 

6.  Hot oil is lammable - keep open lames away from hot oil and oil vapors.

7.  Unplug unit, turn off and let it cool before cleaning or moving.

8.  Do not spray controls or outside of unit with liquids or cleaning agents.

9.  Do not operate unit in public areas and/or around children.

10. The unit and oil may be hot even though the Pilot Light is not on.

11. Do not operate if unit has been damaged or is malfunctioning in any way. 

12. Do not tamper with the Safe Operation Switch or Over Temperature 

Protection Switch.

13. Do not spray controls or outside of unit with liquids or cleaning agents.

14. Do not clean the unit with steel wool.

15. Dispose of oil in an environmentally responsible manner.

f

Unction

 

and

 p

Urpose

This unit is intended to be used for deep frying foods in commercial 

foodservice operations only. It is not intended for household, industrial or 

laboratory use. 
Before using this equipment it must be cleaned and 

dried thoroughly

. Clean 

all surfaces before use. Failure to clean surfaces before using the unit could 

cause food contamination.

Total Restaurant Supply - https://totalsupply1.com - Toll Free 1-800-944-9304 - Local 507-288-9454

2940 Hwy 14 W, Rochester, MN 55901

Summary of Contents for 40705

Page 1: ... Description Voltage HZ kW Plug 40705 10 lb Countertop Fryer 120V 50 60 1 8 15 Amps 5 15P 40706 10 lb Countertop Fryer 220V 50 60 2 5 11 3 Amps 6 15P 40707 20 lb Countertop Fryer 120V 50 60 2 x 1 8 2 x 15 Amps 2 x 5 15P 40708 20 lb Countertop Fryer 220V 50 60 2 x 2 5 2 x 11 3 Amps 2 x 6 15P One 1 dedicated 20 Amp circuit with a single outlet is required for each fryer head Two separate dedicated 2...

Page 2: ...c burners or excessive heat 9 Use only grounded electrical outlets matching the nameplate rated voltage 10 Do not use an extension cord with this equipment 11 Do not spray controls or outside of unit with liquids or cleaning agents safety precaUtions To ensure safe operation read the following statements and understand their meaning This manual contains safety precautions which are explained below...

Page 3: ...ard Do not touch hot liquid or heating surfaces while unit is heating or operating Hot liquids and food can burn skin Allow the hot liquid to cool before handling Do not drop or spill water into hot oil as it will spray or splatter the hot oil out of the tank WARNING Fire Hazard Overheated oil or oil vapors can ignite causing a ire Monitor oil temperature quality and level Use and maintain oil vap...

Page 4: ...moval system Heat oil carefully If oil smokes reduce heat Do not leave unit unattended If ire occurs turn unit off cover until cool Do not put water on hot or laming oil Do not operate with oil below low oil mark Dirty oil has a lower lash point Replace oil on a regular basis Maintain correct oil level Use an oil vapor removal system hood to reduce oil and grease buildup on wall or ceiling surface...

Page 5: ...ace Thermostat Control Oil heats slowly Low or incorrect voltage to unit Verify that voltage rating in unit matches the source voltage If not have qualiied electrical personnel install proper source voltage Oil boils over top when frying Too much oil in well Reduce the amount of oil in well Too much food in basket Reduce the amount of food in basket Too much water in food Dry food product or remov...

Page 6: ...ensor 11 XFA0011 Micro Switch 12 XFFA0012 Safe Operation Switch 13 N A Back Plate 14 XCOA1013 Power Cord Restraint 15 XAA0005 Power Cord 120V NEMA 5 15P Plug 15 XAA0006 Power Cord 220V NEMA 6 15P Plug 16 N A Element Cover 17 XFFA0002 Heating Element 120V 1800 Watt 17 XFFA0003 Heating Element 220V 2500 Watt 18 FFB1250 Basket Small 19 FFB2250 Basket Large 20 XFEIN001 Fryer Insert 21 N A Hinge Right ...

Page 7: ... 9 17 16 18 19 10 13 11 12 20 25 23 21 24 7 8 6 14 15 22 1 26 26 23 21 21 22 22 eXploded vieW coUntertop fryer models 40705 40706 40707 40708 Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Page 8: ...stat 3 XAA0011 Pilot Light 120V Amber 4 XFA0011 Micro Switch 5 XFFA0002 Heating Element 120V 1800 Watt Wiring diagram models 40706 and 40708 Callout Part Number Description 1 XFFA0009 Safety Thermostat 2 XFFA0008 Temperature Control Thermostat 3 XAA0002 Pilot Light 220V Red 4 XFA0011 Micro Switch 5 XFFA0003 Heating Element 220V 2500 Watt Total Restaurant Supply https totalsupply1 com Toll Free 1 8...

Page 9: ...Countertop Cooking equipment 9 ENGLISH OperatOr s Manual notes Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Page 10: ...RANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE As The Vollrath Company LLC s only responsibility and the purchaser s only remedy for any breach of warranty The Vollrath Company LLC will repair or at its option replace the defective product or part without charge except as otherwise provided below For refrigeration compressors and the second year of the warranty on Cayenne Heat Strips...

Page 11: ...co com NO WEB ACCESS If you do not have access to the web kindly register by completing the warranty registration form and faxing it to The Vollrath Co LLC ofice in the country of purchase Warranty registration business name key ContaCt name email street address City state Zip Code Country phone fax model item number serial number operation type R Limited Service Restaurant R Full Service Restaura...

Page 12: ...3201 U S A Main Tel 800 628 0830 Fax 800 752 5620 Technical Services 800 628 0832 Service Fax 920 459 5462 Canada Service 800 695 8560 2010 The Vollrath Company L L C Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Reviews: