![Volkswagen Passat 1995 Official Factory Repair Manual Download Page 104](http://html.mh-extra.com/html/volkswagen/passat-1995/passat-1995_official-factory-repair-manual_1045486104.webp)
01-80
Switch to resistance measuring range 200
Test
step
VAG
1598/18
sockets
Test of
Test
conditions
- Additional
operations
Specified
value
Repairing malfunction
5
63 + 1 Multi-Function
Transmission
Range (TR) Switch -
F125-
- Selector lever
positions R, N, D,
3 and 2
infinite
1
- Check wiring according
to wiring diagram
- Check connector on
Multi-Function TR Switch
-F125- for corrosion and
replace if necessary
- Replace Multi-Function
TR Switch -F125-
page 01-15
,
31
- Selector lever
positions P and 1
0.8 to 1
40 + 1
- Selector lever
positions P, R, 2
and 1
infinite
1
- Selector lever
positions N, D
and 3
0.8 to 1
62 + 1
- Selector lever
positions P, R, N
and D
infinite
1
- Selector lever
positions 3, 2 and
1
0.8 to 1
18 + 1
- Switch to voltage measuring
range
20 V
- Selector lever
positions P, R,
and N
approx.
Battery
Positive
Voltage (B+)
Page 28 of 33
Transmission electrical testing
12/6/2004
http://ebahn.bentleypublishers.com/vw/servlet/Display?action=Goto&type=repair&id=VW.B4.AT02.01.3
WWW.ALL-TRANS.BY