10
SECTION 2 - TECHNICAL DATA
2.1 Central Heating
Vision 25C
Vision 30C
Heat input (kW)
20.00
25.00
Maximum heat output (kW) 60/80°C
19.50
24.45
Minimum heat output (kW) 60/80°C
4.91
5.90
Maximum heat output (kW) 30/50°C
20.84
26.23
Minimum heat output (kW) 30/50°C
5.36
6.40
Minimum working pressure
0.25-0.45 bar
Maximum working pressure
2.5 bar
Minimum flow rate
350 l/h
2.2 Domestic Hot Water
Vision 25C
Vision 30C
Heat input (kW)
25.00
29.00
Flow Rate: ΔT35°C
10.20
12.0
Maximum inlet pressure
6 bar
Minimum inlet pressure
0.15 bar
Minimum flow rate
2 l/min
2.3 Gas Pressures
Vision 25C
Vision 30C
Inlet pressure (G20)
20.0 mbar
20.0 mbar
Heating maximum gas rate (m3/hr)
2.12
2.64
DHW maximum gas rate (m3/hr)
2.64
3.07
Minimum gas rate (m3/hr)
0.53
0.63
Injector size (mm)
5.1
5.6
Silencer flange (ø mm) (fitted)
31
-
2.4 Expansion Vessel
Vision 25C
Vision 30C
Capacity
8 litres
Maximum system volume
74 litres
Pre-charge pressure
1 bar
2.5 Dimensions
Vision 25C
Vision 30C
Height (mm)
715
Width (mm)
405
Depth (mm)
248
Dry weight (kg)
27
28
2.6 Clearances
Vision 25C
Vision 30C
Sides
12mm
Top
150mm from casing or 25mm above flue elbow (whichever is applicable)
Bottom
150mm
Front
600mm
2.7 Connections
Vision 25C
Vision 30C
Flow & return
22mm
Gas
15mm
DHW hot & cold
15mm
Safety valve
15mm
Condense
21mm
2.8 Electrical
Vision 25C
Vision 30C
Power consumption (Watts)
110
119
Voltage (V/Hz)
230/50
Internal fuse
3.15A T (for PCB) - 3.15A F (for connections block)
External fuse
3A
2.9 Flue Details (concentric 60-100)
Vision 25C
Vision 30C
Maximum horizontal flue length (60/100mm)
5.85m
4.85m
Maximum vertical flue length (60/100mm)
6.85m
5.85m
2.9A Flue Details (concentric 80-125)
Vision 25C
Vision 30C
Maximum horizontal flue length (80/125mm)
15.3m
12.8m
Maximum vertical flue length (80/125mm)
20.3m
17.8m
2.9B Flue Details (twin pipes)
Vision 25C
Vision 30C
Maximum horizontal flue length (80mm/80mm)
45m/45m
40m/40m
Maximum vertical flue length (80mm/80mm)
45m/45m
40m/40m