Supplied By www.heating spares.co Tel. 0161 620 6677
1
INTRODUCTION
Fig.1 General Layout
1
Diverter valve motor
2
Discharge valve
3
Domestic hot water heat exchanger
4
Safety valve
5
Pump
6
Pressure switch
7
Auto air vent (AAV)
8
Electrode
9
Main burner
10 Main heat exchanger
11 Latent heat collector
12 Flue gas analysis test point
13 Flue outlet
14 Air intake
15 Differential pressure switch
16 Silicone pressure tube (-)
17 Silicone pressure tube (+)
18 Fan assembly
19 CH NTC sensor
20 Combustion chamber
21 High limit thermostat
22 Expansion vessel
23 Condensate pressure switch
24 Ignition transformer
25 Condense trap
26 Modulator coil
27 Gas valve
28 DHW flow switch
29 Pressure gauge
30 DHW temperature selector
31 Mode selector switch
32 Status fault/indicator led
33 CH temperature selector
34 Timeclock
The Compact HE range of appliances is comprised of 2
models of high-efficiency combination boiler with inputs
to heating & DHW of 25, 29 & 35kW respectively. Each
appliance - by design - incorporates electronic ignition,
circulating pump, expansion vessel, safety valve, pres-
sure gauge, and automatic by-pass.
The Compact HE range is produced as room sealed,
category II2H3P appliances, suitable for internal wall
mounting applications only. They are provided with a fan
powered flue outlet with an annular coaxial combustion
air intake that can be rotated - horizontally - through 360
degrees for various horizontal or vertical applications.
The Compact HE range can also be used with the Vokera
twin flue system.
The Compact HE range is approved for use with C12 &
C32 type flue applications.
These appliances are designed for use with a sealed
system only; consequently they are not intended for use
on open vented systems
Fig. 1
29
30
31
32
33
34