background image

 

Instruction and Operating Manual 

 

Overspeed Protector CTO-B45202

 

 

 

 

 

 

2019 / 02 

 

J.M. Voith SE & Co. KG │ Division Digital Ventures 

Page: 25 / 25 

918 3626018864 en 

D – 74564 Crailsheim 

Version: 2.1 

 

 

 

 

 

   

 

 

   

 

 

   

 

 

3800 

00000000 

  64 

5549 

01000000 

  128  7299 

10000000 

  192  9048 

11000000 

3827 

00000001 

  65 

5577 

01000001 

  129  7326 

10000001 

  193  9075 

11000001 

3855 

00000010 

  66 

5604 

01000010 

  130  7353 

10000010 

  194  9103 

11000010 

3882 

00000011 

  67 

5631 

01000011 

  131  7381 

10000011 

  195  9130 

11000011 

3909 

00000100 

  68 

5659 

01000100 

  132  7408 

10000100 

  196  9157 

11000100 

3937 

00000101 

  69 

5686 

01000101 

  133  7435 

10000101 

  197  9185 

11000101 

3964 

00000110 

  70 

5713 

01000110 

  134  7463 

10000110 

  198  9212 

11000110 

3991 

00000111 

  71 

5741 

01000111 

  135  7490 

10000111 

  199  9239 

11000111 

4019 

00001000 

  72 

5768 

01001000 

  136  7517 

10001000 

  200  9267 

11001000 

4046 

00001001 

  73 

5795 

01001001 

  137  7545 

10001001 

  201  9294 

11001001 

10 

4073 

00001010 

  74 

5823 

01001010 

  138  7572 

10001010 

  202  9321 

11001010 

11 

4101 

00001011 

  75 

5850 

01001011 

  139  7599 

10001011 

  203  9349 

11001011 

12 

4128 

00001100 

  76 

5877 

01001100 

  140  7627 

10001100 

  204  9376 

11001100 

13 

4155 

00001101 

  77 

5905 

01001101 

  141  7654 

10001101 

  205  9403 

11001101 

14 

4183 

00001110 

  78 

5932 

01001110 

  142  7681 

10001110 

  206  9431 

11001110 

15 

4210 

00001111 

  79 

5959 

01001111 

  143  7709 

10001111 

  207  9458 

11001111 

16 

4237 

00010000 

  80 

5987 

01010000 

  144  7736 

10010000 

  208  9485 

11010000 

17 

4265 

00010001 

  81 

6014 

01010001 

  145  7763 

10010001 

  209  9513 

11010001 

18 

4292 

00010010 

  82 

6041 

01010010 

  146  7791 

10010010 

  210  9540 

11010010 

19 

4319 

00010011 

  83 

6069 

01010011 

  147  7818 

10010011 

  211  9567 

11010011 

20 

4347 

00010100 

  84 

6096 

01010100 

  148  7845 

10010100 

  212  9595 

11010100 

21 

4374 

00010101 

  85 

6123 

01010101 

  149  7873 

10010101 

  213  9622 

11010101 

22 

4401 

00010110 

  86 

6151 

01010110 

  150  7900 

10010110 

  214  9649 

11010110 

23 

4429 

00010111 

  87 

6178 

01010111 

  151  7927 

10010111 

  215  9677 

11010111 

24 

4456 

00011000 

  88 

6205 

01011000 

  152  7955 

10011000 

  216  9704 

11011000 

25 

4483 

00011001 

  89 

6233 

01011001 

  153  7982 

10011001 

  217  9731 

11011001 

26 

4511 

00011010 

  90 

6260 

01011010 

  154  8009 

10011010 

  218  9759 

11011010 

27 

4538 

00011011 

  91 

6287 

01011011 

  155  8037 

10011011 

  219  9786 

11011011 

28 

4565 

00011100 

  92 

6315 

01011100 

  156  8064 

10011100 

  220  9813 

11011100 

29 

4593 

00011101 

  93 

6342 

01011101 

  157  8091 

10011101 

  221  9841 

11011101 

30 

4620 

00011110 

  94 

6369 

01011110 

  158  8119 

10011110 

  222  9868 

11011110 

31 

4647 

00011111 

  95 

6397 

01011111 

  159  8146 

10011111 

  223  9895 

11011111 

32 

4675 

00100000 

  96 

6424 

01100000 

  160  8173 

10100000 

  224  9923 

11100000 

33 

4702 

00100001 

  97 

6451 

01100001 

  161  8201 

10100001 

  225  9950 

11100001 

34 

4729 

00100010 

  98 

6479 

01100010 

  162  8228 

10100010 

  226  9977 

11100010 

35 

4757 

00100011 

  99 

6506 

01100011 

  163  8255 

10100011 

  227  10005 

11100011 

36 

4784 

00100100 

  100  6533 

01100100 

  164  8283 

10100100 

  228  10032 

11100100 

37 

4811 

00100101 

  101  6561 

01100101 

  165  8310 

10100101 

  229  10059 

11100101 

38 

4839 

00100110 

  102  6588 

01100110 

  166  8337 

10100110 

  230  10087 

11100110 

39 

4866 

00100111 

  103  6615 

01100111 

  167  8365 

10100111 

  231  10114 

11100111 

40 

4893 

00101000 

  104  6643 

01101000 

  168  8392 

10101000 

  232  10141 

11101000 

41 

4921 

00101001 

  105  6670 

01101001 

  169  8419 

10101001 

  233  10169 

11101001 

42 

4948 

00101010 

  106  6697 

01101010 

  170  8447 

10101010 

  234  10196 

11101010 

43 

4975 

00101011 

  107  6725 

01101011 

  171  8474 

10101011 

  235  10223 

11101011 

44 

5003 

00101100 

  108  6752 

01101100 

  172  8501 

10101100 

  236  10251 

11101100 

45 

5030 

00101101 

  109  6779 

01101101 

  173  8529 

10101101 

  237  10278 

11101101 

46 

5057 

00101110 

  110  6807 

01101110 

  174  8556 

10101110 

  238  10305 

11101110 

47 

5085 

00101111 

  111  6834 

01101111 

  175  8583 

10101111 

  239  10333 

11101111 

48 

5112 

00110000 

  112  6861 

01110000 

  176  8611 

10110000 

  240  10360 

11110000 

49 

5139 

00110001 

  113  6889 

01110001 

  177  8638 

10110001 

  241  10387 

11110001 

50 

5167 

00110010 

  114  6916 

01110010 

  178  8665 

10110010 

  242  10415 

11110010 

51 

5194 

00110011 

  115  6943 

01110011 

  179  8693 

10110011 

  243  10442 

11110011 

52 

5221 

00110100 

  116  6971 

01110100 

  180  8720 

10110100 

  244  10469 

11110100 

53 

5249 

00110101 

  117  6998 

01110101 

  181  8747 

10110101 

  245  10497 

11110101 

54 

5276 

00110110 

  118  7025 

01110110 

  182  8775 

10110110 

  246  10524 

11110110 

55 

5303 

00110111 

  119  7053 

01110111 

  183  8802 

10110111 

  247  10551 

11110111 

56 

5331 

00111000 

  120  7080 

01111000 

  184  8829 

10111000 

  248  10579 

11111000 

57 

5358 

00111001 

  121  7107 

01111001 

  185  8857 

10111001 

  249  10606 

11111001 

58 

5385 

00111010 

  122  7135 

01111010 

  186  8884 

10111010 

  250  10633 

11111010 

59 

5413 

00111011 

  123  7162 

01111011 

  187  8911 

10111011 

  251  10661 

11111011 

60 

5440 

00111100 

  124  7189 

01111100 

  188  8939 

10111100 

  252  10688 

11111100 

61 

5467 

00111101 

  125  7217 

01111101 

  189  8966 

10111101 

  253  10715 

11111101 

62 

5495 

00111110 

  126  7244 

01111110 

  190  8993 

10111110 

  254  10743 

11111110 

63 

5522 

00111111 

  127  7271 

01111111 

  191  9021 

10111111 

  255  10770 

11111111 

 

Table 1:  Values for switch positions to adjust the turbine trip frequency

 

1 bit corresponds to 27.333 Hz; for calculation, see Chapter 6.1,  
for tolerances, see Chapter 1 
 

Format: / decimal number / turbine trip frequency / binary number/  

Summary of Contents for 91868550

Page 1: ...1 25 918 3626018864 en D 74564 Crailsheim Version 2 1 7 Overspeed Protector Type CTO B45202 Translation of the Original version Instruction and Operating Manual Version 2 1 ATTENTION Please make sure...

Page 2: ...No 49 0 7951 32 500 After Sales Service of Product Group Division Digital Ventures Direct dial 49 7951 32 470 Direct fax 49 7951 32 605 Email turcon voith com Address for deliveries of goods Voith Gro...

Page 3: ...n of symbols and warnings 6 2 2 Proper use 6 2 3 Important information 6 2 4 Warranty 8 3 Function 9 3 1 Mechanical design 9 3 2 Operation 10 3 3 Trip criteria 10 4 Packing Storage and Transportation...

Page 4: ...ion Outdoor installation Offshore Industr atmosph Hydraulic Data Supply pressure Pmax 25 bar Operating medium Type Hydraulic oil as per DIN 51524 Turbine oil as per DIN 51515 High flash point fluid 1...

Page 5: ...ms 25ms Trip time of overspeed shutdown 40ms at Toil 40 C 8 Trip criteria See Chapter 3 4 5 Permanent operation of CTO is allowed within this supply voltage range 6 The indication refers to the trip f...

Page 6: ...y valve via a restoring spring designed with substantial power reserves This procedure reliably connects the way valve outlet with the tank return line and the trip stop valve will close The overspeed...

Page 7: ...nd objects Prior to performing any work on the overspeed protector switch off the hydraulic and electric auxiliary energy Electric components are integrated in the overspeed protector which may be des...

Page 8: ...ew fitting of the cable entry on the control magnet VRM is secured against distortion Do not distort or slacken the screw fitting 2 4 Warranty The terms and conditions mentioned in the General Terms a...

Page 9: ...rotector consists of the main functional units 1 Control magnet VRM P supply pressure 2 Tappet for power transmission A output 3 Potentiometer T4 T Tank return line 4 Electrical connection 5 Control h...

Page 10: ...coil current which generates a magnetic force FMag and adjusts the piston of the 3 2 way valve against the progressively designed restoring spring The coil current is then reduced and the control pis...

Page 11: ...trip but the internal release frequency threshold is reduced for a short time whereas the CTO is released internally for this time and thus a tiny movement of the trip stop cylinder can be seen The i...

Page 12: ...tor is stored in a dry location If it is intended to store the overspeed protector for a longer period of time special precautions have to be taken Coordinate such precautions for each individual case...

Page 13: ...tector Cleanliness is imperative during both installation and connection Prevent any impurities dust metal chips etc from getting into the interior of the overspeed protector or into the piping system...

Page 14: ...n removing the screw plugs Collect the oil in a suitable container and dispose of it properly Do not use fibrous or hardening sealing compounds such as hemp or mastic for sealing the connections and p...

Page 15: ...requency has to be documented Confirmation of the new adjustment by means of a documented trip test is mandatory before operating the turbine For safety reasons the overspeed protector is set to the m...

Page 16: ...m width across flats used to fix cover C see Fig 3 and remove the cover On account of the seal in cover C it is not easy to move It may therefore be helpful to first turn the cover and then lift it us...

Page 17: ...e actual speed remove indication readjust the 4 mA value using the If potentiometer for speed 0 after adjustment of the trip frequency See Chapter 6 2 If potentiometer After setting the coding switche...

Page 18: ...mA signal In case of a trip of the CTO the actual speed remote indication returns to 0 mA due to the external switch off of the 24V CTO supply In case this external switch off of the 24V supply is pre...

Page 19: ...eated pushing and releasing the pushbutton trip simulation adjusts the potentiometer The potentiometer is adjusted in steps clockwise and the trip stop valve is observed The trip time is set correctly...

Page 20: ...r signal trip and is the external trip signal available after opening of external trip loop Press the Reset button Disconnection when on exceeding SS frequency external trip loop is interrupted overvo...

Page 21: ...l trip loop closed Close contact external trip Press the Reset button Disconnect supply voltage yes B A C Have the trip signals been reset To exclude a speed pick up defect connect a 1 KOhm 10 resisto...

Page 22: ...ate operating phases Monitor the overspeed protector operating behavior for any changes Analyze and eliminate the causes as required during appropriate operating phases Inspection after approx 740 ope...

Page 23: ...lectronic components and residual oil If the overspeed protector is switched off for repair or inspection purposes or for a system shutdown switch off the oil supply system and release all pressure ac...

Page 24: ...Protector CTO B45202 2019 02 J M Voith SE Co KG Division Digital Ventures Page 24 25 918 3626018864 en D 74564 Crailsheim Version 2 1 9 Annex Table 1 Adjusting values turbine trip frequency Outline D...

Page 25: ...011111 159 8146 10011111 223 9895 11011111 32 4675 00100000 96 6424 01100000 160 8173 10100000 224 9923 11100000 33 4702 00100001 97 6451 01100001 161 8201 10100001 225 9950 11100001 34 4729 00100010...

Page 26: ......

Page 27: ...alle Rechte vorbehalten ISO 16016 Weitergabe sowie Vervielf ltigung dieses Dokuments Verwertung und Mitteilung seines Inhalts sind verboten soweit nicht ausdr cklich gestattet 5k 0 VDC 24VDC ok The d...

Reviews: