background image

15 Software

15.1 Armonía Pro Audio Suite

Armonía Pro Audio Suite™ has been specifically designed 
to be used with Bias Series amplifiers as an easy to use 
configuring interface that allows system setting and 
customization.

Communication between the software and the amplifier 
is established via an RS-485 or Ethernet connection, 
depending on the available ports on the units.

Armonía provides control and monitoring of a wide range 
of amplifier functions, such as attenuation, mute, internal 
temperature and voltage rail monitoring.

On Bias Series equiped with the DSP board Armonía  offers 
full control on all signal processing features, including input 
and output equalization, alignment delays, FIR filters and 
load impedance monitoring, etc.

Armonía is scalable: it allows control of a single Void amplifier 
or a very large system containing many amplifiers. For large 
fixed or touring installations, Armonía gives the operator the 
ability to monitor and control all amplifiers in the system from 
a single location, regardless of the amplifiers’ positions.

hub systems as well as a single hub and linear daisy-chaining. 
A looped Ethernet topology is also permissible, which will 
provide redundancy in the event of a network failure.

An amplifier system using an RS-485 network can either be 
daisy-chained throughout or use the Void PowerHub as a 
local switch. 

This software has been designed to accept software plug-
ins to enable third-party product control.

Armonía is freely available on Void website: it can be 
downloaded after signing up for the user forum: further 
information is available on the software section of Void 
website www.voidacoustics.com.

15.1.1 Networking

Void amplifiers can connect to a PC running Armonía in two 
ways: with an RS-485 serial connection or via Ethernet.

Systems employing both categories of amplifiers may use 
both methods simultaneously: an Ethernet network being 
implemented for some amplifiers, and RS-485 for the others 
(bear in mind that Ethernet is a faster communications 
protocol than serial RS-485).

The range of network topologies which can be used in wiring 
a real system varies between the two communications 
methods.
Ethernet provides a slightly greater degree of freedom, as 
standard IT network switches may be used to create multiple 

Bias Series User Guide V1.0

Page 36

Summary of Contents for Bias V3

Page 1: ...Bias V3 V9 User Guide V1 0...

Page 2: ...com Void Acoustics and the Void logo are registered trademarks of Void Acoustics Research Ltd in the United Kingdom USA and other countries all other Void trademarks are the property of Void Acoustics...

Page 3: ...15 9 3 Amplifier settings Input select 15 9 4 Amplifier settings Max output voltage 15 9 5 Amplifier settings Max mains current 16 9 6 Amplifier settings Clip limiter CH1 CH2 16 9 7 Amplifier settings...

Page 4: ...Save to an empty slot 33 12 4 2 Overwriting an existing preset 33 12 5 Local preset Change lock code 33 12 6 Local preset Erase all presets 33 13 Setup 34 13 1 Setup Hardware info 34 13 2 Setup Hardw...

Page 5: ...or moisture does not operate normally or has been dropped WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT ATTEMPT TO OPEN ANY PART OF THE UNIT NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO Q...

Page 6: ...ld type waste the volume of waste sent to incinerators or land fills will be reduced and natural resources will thus be conserved The Waste Electrical and Electronic Equipment Directive WEEE Directive...

Page 7: ...formance of the amplifier at high levels of out put and avoids mains voltage collapses typical of standard and switching power supplies Another great advantage of this technology is that its performan...

Page 8: ...4 Mechanical drawings FIGURE 2 Bias V3 mechanical drawings Bias Series User Guide V1 0 Page 2...

Page 9: ...FIGURE 3 Bias V9 mechanical drawings Bias Series User Guide V1 0 Page 3...

Page 10: ...alog input in analog mode or AES3 input in AES3 mode according to the position of the switch in 5 D Smart Card slot E Multifunction buttons F LED bar signal metering channel 2 G Main switch 7 Line out...

Page 11: ...in 5 7 Link button link input from channels 1 and 2 8 Input 1 channel 1 analog input 9 Speaker connector output channel 1 10 Speaker connector output channel 2 Bias V9 rear panel 1 2 4 3 5 6 10 7 8 9...

Page 12: ...ct minimum Should however the amplifier be subject to an extreme ther mal load the fan will force a very large volume of air through the heat sink In the extremely rare event that the amplifier should...

Page 13: ...etween the mains connections and the amplifier must be installed inside the rack cabinet Suggested device is 32A 250VAC C or D curve 10kA With Bias V3 provide a sectioning breaker between the mains co...

Page 14: ...uple of XLR jack hybrid combo connectors in Bias V9 amplifiers Signal polarity for XLR and TRS plugs is shown in FIGURE 8 7 3 Analog line output Line out is provided in Bias V3 via a couple of XLR con...

Page 15: ...NG Output terminals are hazardous wiring connection to these terminals require installation by an instructed person and the use of ready made leads Take care to secure the output terminal before switc...

Page 16: ...used to remotely manage the DSP in Bias Series DSP amplifier and enable remote on off Bias Series provided with a AESOP board have a dedicated 2 pin Phoenix connector MCV 1 5 2 G 3 81 1803426 located...

Page 17: ...d PROT 2 With respect to the output clipping threshold TABLE 2 LED chart 8 2 Front display When the amp is turned on the main screen appears after a short presentation The first line of the screen wil...

Page 18: ...ew of the structure of the Main menu FIGURE 20 and DSP settings menu FIGURE 21 accessible via the front panel on Bias Series amplifiers Max Mains Current back fast 22 A rms Max Mains Current back fast...

Page 19: ...ation Input gain sens Inuput select Max output voltage Max mains current Clip limiter CH1 Clip limiter CH2 Gate CH1 Gate CH2 Mute at Power on Idle Mode see DSP Settings diagram Device mode Addressing...

Page 20: ...Mode Soft knee Thresh W Attack ms Release ms Mode Equiv Rout Aux Dly ms Diagnostics Tone in alarm Tone in freq Tone in Vmin Tone in Vmax Tone out gen Tone out ampl Tone out freq Tone out alarm Tone o...

Page 21: ...B 19 0 21 9 35 dB 15 6 18 6 TABLE 4 Maximum balanced input signal vs gain 1 kHz sine wave input before clipping occurs at the output stage These values are reported with respect to the ampli fier s ga...

Page 22: ...57 55 32 dB 60 58 35 dB 63 61 TABLE 6 Gate threshold vs gain 9 8 Amplifier settings Mute at power on This functions allows the user to automatically mute all channels when the amplifier is turned on T...

Page 23: ...he gain trim parameter or by adjusting the analog signal level AES3 from ASEOP the primary audio signal for this configu ration is an AES3 fed via the RJ45 port AESOP DSP Out ref Chapter 7 4 Digital I...

Page 24: ...cific parameter affects both channels the top right hand corner will report this as 1 2 9 11 1 EQs This menu gives access to the parametric output equalizer interface This menu lists the 16 parametric...

Page 25: ...dB point The slope is freely selectable from a minimum of 6 dB octave 1st order filter to 48 dB octave 8th order filter The FIR filters can be selected as normal FIR Linear Phase or enhanced Hybrid F...

Page 26: ...n larger that allowed It acts by re ducing the amplifier gain in order to reduce the measured output peak voltage To limit the dangers of dangerous very fast transient signals all limiters implement a...

Page 27: ...60 500 3000 2 midange 30 100 500 3000 3 midbass 50 150 1000 5000 4 woofer 100 200 2000 5000 4 woofer 150 250 4000 8000 6 woofer 250 500 6000 10000 TABLE 9 Filters parameters Empirical observation yiel...

Page 28: ...is done to obtain the desired damping factor with any cabling used For this end the virtual series resistor can also have a negative value to compensate cabling resistance For example using a 10 mete...

Page 29: ...t test is based on the detection of a pure tone generated by an external tone generator on any input line The output test relies on the measurement of the im pedance at a well defined frequency the am...

Page 30: ...ut section This function disables all output EQ limiters and damping functions Warning this operation may potentially damage connected speakers Pay special attention to shutting down any audio source...

Page 31: ...osing an intermediate device or having a faulty cable link without compromising the ring integrity The AESOP board detects bad quality connections by counting errors on the Ethernet control Faulty con...

Page 32: ...is the default device mode setting This applies to both AES3 A stream and AES B stream indepen dently If an AES3 stream A or B is present as input at both RJ45 ports this can happen when a ring netwo...

Page 33: ...m The AES3 XLR stream will be routed to the AES3 B stream on both primary PORTS 1 and 2 FIGURE 37 The AES3 A stream if present will be repeated from to primary RJ45 ports 1 and 2 10 3 3 Forward to bot...

Page 34: ...ed together in sequence i e in series FIGURE 40 and FIGURE 41 show the diagrams of daisy chain connections of 4 amplifiers with four and two AESOP ports respectively In both configuration only the fir...

Page 35: ...ble failure at a time one degree of redundancy If two or more connections should fail one or more amplifiers depending on where the interruption occurs would be muted 10 4 3 Daisy chain with AES3 and...

Page 36: ...ES3 A from PORT 2 to PORT 1 Repeat AES3 A from PORT 2 to PORT 1 Repeat AES3 A from PORT 2 to PORT 1 Forward to AES3 A 1 2 3 4 Port 4 secondary FIGURE 43 Daisy chain with AES3 and Ethernet redundancy f...

Page 37: ...select the AES3 stream source to feed the output power stage The AES3 signal can come from either AES3 XLR AES3 A or AES3 B Source mode this menu allows to selects the channel s contained the selecte...

Page 38: ...n the other hand is the sum of each single channel s RMS current level The bottom line of the screen displays the load impedance as Zload The minimum output voltage is stored internally and available...

Page 39: ...lly stored presets that cannot be overwritten Either all 50 or none 0 of the presets can be locked After entering the correct lock code select the number of presets to be write protected 12 3 Local pr...

Page 40: ...emote control voltage VAUX indicates if the power supply auxiliary voltage is correct IGBTCONV indicates the DC DC converter monitor status VBOOST internal post PFC voltage 192KHZ system clock frequen...

Page 41: ...restore it to full functioning mode The red LED will be turned off and the amplifier will return to normal operating conditions only when the output current draw returns to acceptable levels 14 3 Ther...

Page 42: ...systems as well as a single hub and linear daisy chaining A looped Ethernet topology is also permissible which will provide redundancy in the event of a network failure An amplifier system using an RS...

Page 43: ...qualified technical personnel In addition to hav ing an in house service department Powersoft supports a network of authorized service centres If your amplifier needs repair contact your Powersoft dea...

Page 44: ...point Latency 6 0 ms fixed latency architecture Memory Presets 8 MB RAM plus 2 MB flash for presets 50 stored locally 150 stored on SmartCard Delay 4 s input 32 ms output for time alignment Equalizer...

Page 45: ...g point Latency 6 0 ms fixed latency architecture Memory Presets 8 MB RAM plus 2 MB flash for presets 50 stored locally 150 stored on SmartCard Delay 4 s input 32 ms output for time alignment Equalize...

Page 46: ......

Page 47: ......

Page 48: ...Research Ltd Unit 15 Dawkins Road Industrial Estate Poole Dorset BH15 4JY England 44 0 1202 666 006 sales voidacoustics com Registered in England Wales No 07533536 North America Void Acoustics North...

Reviews: