background image

11 

 

 

 Reset Your Phone 

 

1)

 

Press the Menu soft key when the phone is idle, select 

Advanced

 

 Reset

 to reset 

your phone. 

 

2)

 

In the dial-up interface, press * #000000# to reset the phone. 

3)

 

Login web background  select Maintenance

Config click Reset to reset factory 

 

 

HEALTH AND SAFET 

Declaration of Conformity

 

We hereby declare that (all essential radio test suites have been carried out and 

that) the above named product is in conformity to all tile essential requirements 

or Directive (RED) 2014/53/EU. 

Summary of Contents for M2

Page 1: ...VOGTEC IP PHONE Mobex T Series ...

Page 2: ...formation about this guide is subject to change without prior notice The user shallbe solely responsiblefortheapplication oftheproduct Vogtecnoguarantee including butnotlimitedto impliedguaranteeofmerchant ability and fitness for a particular purpose Vogtec shall not be liable for any consequential orincidental damages resulting from theincorrect use of thisguide The equipment complies with thebasi...

Page 3: ...ance of less than 1 5 m from a water source Keep the device away from water or any form of liquid Donot use thedevice in environments wheretherearerisks of explosions Do not use your phone while driving Park the car before making or answeringacall Turn off your phone when refueling Do not use your phone near a gas station flammable or chemical substances Warning It may explode whenexposedinfire Do n...

Page 4: ...if an unsuitable or unauthentic adapter is used The battery should never be opened or exposed or flames Disposetheused batteriesaccordingtothe current guidelinesand regulations 6 The correct operation of medical appliances may be altered by the use of mobile phones Pacemaker manufacture recommend that a minimum distance of 20cm between devices when the mobile phone is on Do not carry your phone in ...

Page 5: ...strator Handset Battery Charging base Chargecable Power Adapter Belt clip Quick Start Guide Note The models displayed on the phone differ from each other The packaging content IP Phone listed above takes a Mobex T3 IP phone as an example Werecommend that you use theaccessoriesprovided orapproved by original factory The use of unapproved third party accessories may result in reduced performance ...

Page 6: ...bling thePhone Insert battery DeskMountMethod Connect the power Note The IP phone should be used with original factory power adapter only The use of the third party power adapter may cause the damage to the phone ...

Page 7: ...d in the login page and click login Account Settings Click on SIP Parameters of the account Enable Account You can check Disabled to enable disable the account Status It shows the register status of the current account Enable Register You can select Enabled Disabled to enable disable the account Register Server It is provided by ITSP for registration required Server Port It is provided by ITSP for...

Page 8: ...s is 192 168 0 8 enter 192 168 0 8 in idle and press the key Answering a Call Press key in the incoming call Note You can reject an incoming call by pressing the Reject sot key key Ending a Call Press key Redial Press key to enter the calls list press or to select the desired entry andthen Call Mute and Un mute Press tomutethemicrophoneduringa call Press again to un mutethe call Call Hold and Resu...

Page 9: ... to and then key 3 Press Option soft key to expand the submenu options and select Transfer feature when the second party answers Call Forward To enable call forward 1 Press the Menu soft key when the phone is idle and then select Call Forward 2 Selectthedesiredforwardtype Always Incoming calls are forwarded unconditionally Busy Incoming calls are forwarded when the phone is busy No Answer Incoming...

Page 10: ...he list you can do the following Press key to call the entry If you press the Option soft key you can also do the following Select Call to call the entry Select Message to send message the entry Select Add to Contact to add the entry to the local directory Select Add to Blacklist to add the entry to the blacklist Select Delete to delete the entry from the list Select Delete All to delete all entri...

Page 11: ...to adjust the ringer volume Ring Tones 1 Press the Menu soft key when the phone is idle and then select Preferences Ringtones 2 Press Shift soft key to select the desired ring tone 3 Press key to accept the change LED Instructions Red indicator always bright Charging power Flash red indicator Lowbattery Missedcall UnreadMessage Greenindicator Full Charge Update YourPhone Update firmware through FOT...

Page 12: ...ess 000000 to reset the phone 3 Login web background select Maintenance Config click Reset to reset factory HEALTH AND SAFET Declaration of Conformity We hereby declare that all essential radio test suites have been carried out and that the above named product is in conformity to all tile essential requirements or Directive RED 2014 53 EU ...

Page 13: ...sorbed radio quantity when using mobile devices SAR lasts are conducted using standard operating position with the phone transmitting as its highest certified power level however tile actual SAR level of the phone while operating can be well below tile maximum value In general the closer you are to a base station the lowerthepoweroutputorthephone The SAR values may vary depending on different model...

Page 14: ...ed OFF such as heart pacemakers hearing aids etc Most medical devices can shield the phone s RF signal but some cannot If you haveany doubts or need to find out more please consult your doctor or medical device manufacturer Care and maintenance Yourphone is a product of superior design and craftsmanship and should betreated with care The suggestions below will allow you to enjoy this product for ma...

Page 15: ...tery gets wet and the label on the phone is damaged phone repairs are no longerguaranteed by the manufacturer s warranty even if the warrantyfaryourphonehasnotexpired Manufacturer Shenzhen Vogtec Technology Co Ltd Address 509 512 5 F Kanghesheng Bldg No 1 Chuangsheng Rd Nanshan District Shenzhen 518055 China ...

Page 16: ... range of 21 to 320 kbps of guaranteed priority bandwidth is required per call depending on the sampling rate the VoIP codec and Layer 2 media overhead Limitations and Factors Affecting Throughput First and foremost throughput to the Internet is capped by the ISP and devices upstream of the APs Also 802 11 is a shared medium and is limited by other devices connected to the wireless Therefore throu...

Page 17: ...in reasonable expectations for connection speeds and keep the above factors in mind Maximizing Throughput Optimal throughput rates and wireless performance in general can be improved by mounting APs correctly high up on a wall or on the ceiling Additionally placing APs away from kitchens and other areas with high interference will also result in better performance In a mesh environment throughput ...

Page 18: ...jitter and drop 3 Test steps 3 1 Open the iPerf software on the PC and configure the UDP and server mode as shown in the screenshot below 3 2 Handheld terminal via the Menu Advanced iPerf open iPerf test software just enter the address of the server then use the arrow keys to move to Start and click the left soft button to Start the test ...

Page 19: ...18 3 3 Check whether the test results can meet the VoIP business requirements ...

Reviews: