background image

 

 

M2M Easy 2  

Security Communicator

®

 

Installation Guide 

for firmware v2.1 R08 

 

_____________________________________ 

Rev: 2.2 

 

2017-02-09

 

 

Summary of Contents for Easy 2

Page 1: ...M2M Easy 2 Security Communicator Installation Guide for firmware v2 1 R08 _____________________________________ Rev 2 2 2017 02 09...

Page 2: ...cument Type Installation Guide for v2 1 R08 Device M2M Easy 2 Security Communicator Author T th Csaba Benyhe Tam s T th Zolt n Horv th Attila Tam s WM Systems LLC Contact Email csaba toth m2mserver co...

Page 3: ...he device 22 4 3 Status and device data 25 4 4 Terminal window communication messages 26 4 5 File handling 26 4 6 Contact list for output control and gate opening 28 4 7 Firmware upload refresh 30 4 8...

Page 4: ...call notification ringing 72 6 7 Gate opening 72 7 Configuration by SMS messages 73 7 1 Authentication command 73 7 2 Query commands 75 7 3 Parametrizing by commands 75 7 4 Examples for SMS command p...

Page 5: ...2pcs connector for input lines for sensors sabotage 5 Jumpers for the input lines IN1 IN2 to select the operation mode voltage contact cut or short 6 OUT 1pc relay output for switching a siren bark 7...

Page 6: ...e inputs The device has 2 input lines IN1 IN2 where sensors can be connected by connecting its wire pairs in accordance with the standard connection method shown below by fixing the cable wire pairs f...

Page 7: ...he jumpers besides the terminal blocks of the input lines according to the input line nr titles Choosable input line operation modes with the jumpers Contact mode o The input line jumper pairs approac...

Page 8: ...They can be configured seperately to operate as a voltage or contact mode for the input These settings can be setup with the jumpers besides the IN1 IN2 input line s terminal blocks Connecting the re...

Page 9: ...be able to forward its alarm signals in Contact ID format to the remote dispatcher centre Connect the cable wire pair to the ALR title Alarm line s terminal block by sliding the companion piece and in...

Page 10: ...tus In case of normal operation it signs the GPRS communication status See the detailed description ot STA LED part yellow flashing lights IN1 Input 1 signal Signs the status of the 1 input line I1INV...

Page 11: ...us LED yellow The STA LED assures information about the current operation It has 3 modes It twill be active only if the GPRS signal transmission permitted In this case from the beginning of the signal...

Page 12: ...ues its initialization the receiving of serial port commands is still active for parametrizing After 5 minutes the device automatically tries to restart the module 4 flashing The device cannot login t...

Page 13: ...then the INx LED will light according to the related input OUT Output is active yellow The output active indicator OUT LED shows the status of the primer side of the relay When the output is active t...

Page 14: ...Operation requirements General conditions 8 24V power supply with adapter or 12V DC 800mA connected to 230V AC or connected to the 12V 24V output of the alarm center In case of GPRS signal transmitti...

Page 15: ...tp www m2mserver com m2m downloads EasyTerm_v1_3_1_XP_EN ZIP M2M Easy 2 Security Communicator firmware R08 system software uploaded to the device by factory default if it is needed the related BIN ext...

Page 16: ...steps 3 Mount the GPRS antenna piece of the package as it can be seen in the picture to the copper SMA connector until it sleeves In case of wired antenna find a place to the magnetic antenna and conn...

Page 17: ...or the power supply will be disconnected the device will be turned off 2 2 Turning on the device After starting the Easy 2 it is required ca 40 60 seconds from the startup to the complete operation su...

Page 18: ...Problem troubleshooting part of the Chapter nr 9 When your device was already installed check the current firmware version of the device SWVER value in the EasyTerm application When the version is not...

Page 19: ...the Microsoft Net Framework 4 0 In it is necessary download and install the component Manufacturer website https www microsoft com en us download details aspx id 53344 Configuration files Pre defined...

Page 20: ...at the port settings b In case of using USB port When using the converter cable this is not included in the package the download and installation of the driver is necessary for accessing the Easy 2 It...

Page 21: ...ng and monitoring the current operation of the Easy 2 and refreshing the firmware controlling and switching the outputs e g gate opening via output and of course for the operation of the devices as a...

Page 22: ...larm system or any other proposal then take consider the value Address and Port number when setup and connect to the device Let s configure the further necessary parameters for the proper operation Wh...

Page 23: ...on is active only if the serial connection is currently inactive Close status For login the necessary device IMEI and IP address can be requested by the INFDEV or DEVSTAT SMS text caommands Hint When...

Page 24: ...ble and the device or restart device when it is necesssary if the cable is already connected then push the Connect button for connecting When the EasyTerm is not necessary to use further and you d lik...

Page 25: ...entifier HW ID Easy 2 unique hardware ID SW VER firmware version IP ADDR modem IP address on the network At the right side of the status window the CSQ value is listed signal strength and its graph wi...

Page 26: ...ere you can track the exact operation of the Easy 2 In case of necessary you can Save log and all of the Terminal messages into a text file just add the path and filename and push on the Save The Auto...

Page 27: ...ice at first Use the Write config button Every further configuration should be performed only after the first parameter upload The Prg Address coloumn lists the parameter Name The parameter Value show...

Page 28: ...on at the bottom of the screen The selected values will be sent to the Easy2 The progress indicator signs the current status of the method After the succesfull parameter upload the device will be rest...

Page 29: ...mber to the device then fill the phone number at the Add button in value format e g 49201234567 or 0049301234567 then push the Add button to record the number to the device s contact list Adding multi...

Page 30: ...of the screen and you can control by the buttons manually When the gate opening parameter is enabled Configuration Output settings OUTMODE Gate then at the left side of the screen you can close the ga...

Page 31: ...Then the Easy 2 will receive the firmware file throught the serial connection and starts to refresh its system software The installation progress can be followed at the Terminal window 3 and by the pr...

Page 32: ...ile please wait message Wait for the finishing the upload method and the end of the installation At the end of the installation you will get the File transfer successful message then the device restar...

Page 33: ...d disconnected from the serial port connection 4 8 Device restart If you are attempted to restart the Easy 2 then click on the right side Restart device button at the bottom of the screen Then the dev...

Page 34: ...pter nr 5 4 10 Manual arming The Easy2 alarming can also be controlled manually from the EasyTerm You can control it besides the ARM title in the Status window with the ON OFF buttons in case of using...

Page 35: ...life signals The reading process is assigned by the progress bar Here you can check the status State and the input settings as Type H L High to Low and L H Low to High Arm type EOL and the armed disa...

Page 36: ...rming The zone bypass enabling is also possible through SMS commands by text messages see later In case of using the IO expander board you can also define the bypass feature for the furtherp inputs fr...

Page 37: ...switch are connected to the input lines 2pcs of inputs by the IO expansion max 8pcs siren bark connected to the output the signals are transmitted through GPRS to the server IP address 5 Input monitor...

Page 38: ...signal sending frequency on GSM channel which is setup to 60 seconds by general Check that it is fine or not If you ve changed one of the listed parameter values then the program will highlight the c...

Page 39: ...oloumn check the proper selection push the Write config button at the bottom of the screen At the end of the parameter sending the device is restarting by using the new settings If it is necessary you...

Page 40: ...E code will be signalled The LFFREQ is the life signal sending frequency on GPRS channel which is setup to 300 seconds by general Check that it is fine or not The LFUNIT value is the amount for the LF...

Page 41: ...When using a username or password are needed for the access e g in case of chap authentication then define the UN and PWD values based on the information proven by your mobile service provider When yo...

Page 42: ...Input Parameters view at the Device Type Then the program will load the related parameters All detected and received signals and events of the Easy 2 input lines are stored in a puffer with their tim...

Page 43: ...tion mode the Easy 2 is transmitting to the dispatcher center s IP address or to the remot dispatching software through GPRS The further settings are recommended to check or modify in case of necessar...

Page 44: ...anged value lines by bold For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection push the Write config button at the bottom of the screen The...

Page 45: ...ve changed one of the listed parameter values then the program will highlight the changed value lines by bold For sending the listed parameter values for the device regarding the Selected coloumn che...

Page 46: ...changes When it is necessary to define the current input line s CID event code IxEVENT or the partititon number IxPART zone IxZONE for monitoring sensors or a sabotage switch these parameters must be...

Page 47: ...IxINV as NO Normal Open NC Normal Close parameter At this time the ascending and descending edges are filtered through a time frame the inputs must be hold for a minimal interval in the current status...

Page 48: ...the device is restarting by using the new settings Notification sending settings For the alarm notification and messaging settings open the Notification Parameters parameter group at the Device Type T...

Page 49: ...ou ve changed one of the listed parameter values then the program will highlight the changed value lines by bold For sending the listed parameter values for the device regarding the Selected coloumn c...

Page 50: ...N settings For the GPRS settings choose the GPRS Settings parameter group at the Device Type Then the program will load the related parameters Change the GPRSEN value to Enable to operate the device a...

Page 51: ...ted parameter values then the program will highlight the changed value lines by bold For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection pu...

Page 52: ...the primary IP address of the IP receiver and the PORT1 value for the port number Setup the secondary IP address to the SERVER2 and its port to the PORT2 if it is also necessary Change the IPPROTO pro...

Page 53: ...he next event will be ignored The device tries to signalling the incoming events through GPRS connection to the primary IP address In case of unsuccessful sending e g outage or fall of the primary IP...

Page 54: ...only for the input line nr 1 and 2 The IO expansion settings will be listed later On the input lines of the device it is capable of generating Contact ID messages and transmitting them by the ascendi...

Page 55: ...ged value lines by bold For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection push the Write config button at the bottom of the screen At the...

Page 56: ...vent or wire cut the forwarded CID code can be defined In case of a sabotage wire cut the SMS message can also be configured by the ISABON parameter The recovery message by the ISABOFF definition If y...

Page 57: ...disarm for the alarm system To switching the siren you can add it for the incoming input line alarm events by the SIRENOUT parameter when alerting the siren will be turned on The SIRENDEL defines the...

Page 58: ...r changed its position in case affect of the appropriate trigger The trigger event can be also for mono stable and bi stable modes the OUTON and OUTOFFcommand value or ringing e g gate opening If you...

Page 59: ...anged value lines by bold For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection push the Write config button at the bottom of the screen At t...

Page 60: ...ALLTOKENS parameters regarding its values In case of neccessary you can save the configuration to your computer by the Save file button Please also check the Chapter 5 6 5 5 Monitoring input lines and...

Page 61: ...ge detection ascending descending can be reversed by the IxINV as NO Normal Open NC Normal Close parameter At this time the ascending and descending edges are filtered through a time frame the inputs...

Page 62: ...the proper selection push the Write config button at the bottom of the screen At the end of the parameter sending the device is restarting by using the new settings Notification sending settings For...

Page 63: ...mobile provider SMS notifications and SMS commands will be not forwarded ISABEVENT in case of a sabotage event or wire cut the forwarded CID code can be defined In case of a sabotage wire cut the SMS...

Page 64: ...r the input line nr 1 and 2 The IO expansion settings will be listed later Gate opening and output controlling settings For configuring the gate opening open the Output Settings parameter group at the...

Page 65: ...not switch back In Bi stable mode there is no delay From the opened or closed standing positions the relay can be switched or changed its position in case affect of the appropriate trigger The trigge...

Page 66: ...e listed parameter values then the program will highlight the changed value lines by bold For sending the listed parameter values for the device regarding the Selected coloumn check the proper selecti...

Page 67: ...er allows the immediate status sending and signalling when the device starting up When it is enabled then in case of a restart or turning off the Easy2 will automatically sends the restart status e g...

Page 68: ...ameter sending the device is restarting by using the new settings In case of neccessary you can save the configuration to your computer by the Save file button 5 7 Firmware update refresh from FTP ser...

Page 69: ...fresh progress status SMS notification in case of installation from an ftp server by the FTPSMS parameter You can setup the success text message for case of successful installation by FTPSUCC paramete...

Page 70: ...rder of the primary and secondary server operation can be defined by the SFUNCT parameter The device switches from the primary to the secondary server when the primary server cannot transmit data If t...

Page 71: ...are not defined then the device is unable to signalling 6 4 Receiving the signalling of events The device can receive events from two sources from the alarm system TIP RING port or its input line or t...

Page 72: ...then the other input assigned numbers will be also inactivated The ringing is successful when the called number is receiving or rejected the call within 20 seconds In other case the device continuous...

Page 73: ...enabled the caller who remotely controls the gate will receive an SMS notification about the status of the input in mono stable mode the delay value will be also reported The definition of the phone...

Page 74: ...rameter value after the character can be empty The question mark after the parameter means the query of the current parameter You cannot use any of the commands or responses as OK or NO or ERROR for p...

Page 75: ...lines the output line INFTEL Configured voice SMS notification settings phone numbers and notification SMS text message order sequence voice call ringing order sequence will be responsed Containing p...

Page 76: ...uccesful ftp firmware update as port IP address ftp username and password etc Bypass disabling a zone specific commands The BYPASS parameters can be only executed via SMS commands and also possible to...

Page 77: ...the phone number value can be added here When it is already exists or the memory is full then there is no affection GATERM Hat s ra a megadott sorsz m h v sz m t rl dik a list b l Value telefonsz m s...

Page 78: ...GSM transmiter pre configured for this operation mode by general The alarm system is connected to the TIP RING input port the received CID codes are forwarded through the GSM network and signalling to...

Page 79: ...7 TEL2 36207654321 I1S 1 I1ON FAIL RES ET PW ABCD I1OFF GOOD SMSFWD 1 ISABEVENT 331 ISABON SABOTAGE ISABOFF GOOD I1S 1 I2S 1 OUTMODE 1 ARMSMS 1 ARMON ARM ARMOFF DISARM ARMFAIL ARM FAIL RESET PW ABCD A...

Page 80: ...botage recovery 3141 Ftp firmware update started 1991 Ftp firmware update succesfully finished 1992 Ftp firmware update in progress 1993 1 Device start in case of hw startup restart by software Parame...

Page 81: ...with the zone value which shows the interface where the login were attempted CID code E627 Partition 99 Zone TCP 0x20 Serial 0x30 4 Logout from Programming mode for dispatcher centre Parameter Descri...

Page 82: ...nuously or flashing slowly the SIM card is not inserted properly K rj k hogy ellen rizze a SIM k rtya behelyez s t vagy helyezze be jra a foglalatba Remove the SIM card then insert it again Please che...

Page 83: ...n the Connection window 1 by the Close button and remove the serial connection from the computer side Then reconnect the cable and push on the Open button If you ve received the Login Failed message i...

Page 84: ...utage or providing trouble and the GSM state is not available wait for a couple of minutes and push on the Restart device button for the device restart Then please check the network connection and sta...

Page 85: ...85 No SIM card presented or wrong SIM When there is no available SIM ICC identifier Turn off the device and check the proper SIM card insertion and start the device Reconnect and check the settings...

Page 86: ...you can contact us in the following ways Email support m2mserver com Telephone 36 20 333 1111 10 1 Support help For identifying the device please use the sticker on the PCB which contains important i...

Page 87: ...ocumentations and software http m2mserver com en products m2m easy 2 security communicator The documents and softwares related to the product are available at our website http m2mserver com en downloa...

Page 88: ...urce The pictures in the user guide are only for illustration purposes WM Systems LLC does not acknowledge or accept responsibility for any mistakes in the information contained in the user guide The...

Reviews: