© 2021 United States Stove Company

PRE-START-UP CHECK

Remove burn pot, making sure it is clean and none of the 

air holes are plugged. Clean the firebox, and then reinstall 

burn  pot.  Clean  door  glass  if  necessary  (a  dry  cloth  or 

paper  towel  is  usually  sufficient).  Never  use  abrasive 

cleaners on the glass or door. Check fuel in the hopper, 

and refill if necessary.

BUILDING A FIRE

Never use a grate or other means of supporting the fuel. 

Use only the burn pot supplied with this heater. Hopper lid 

must be closed in order for the unit to feed pellets. During 

the start-up period:

• 

Make sure the burn pot is free of pellets.

• 

DO NOT open the viewing door.

•  The damper may need to be closed during startup.
• 

DO NOT add pellets to the burn pot by hand.

NOTE: During the first few fires, your stove will emit an odor 

as the high-temperature paint cures or becomes seasoned 

to the metal. Maintaining smaller fires will minimize this. 

Avoid  placing  items  on  the  stovetop  during  this  period 

because the paint could be affected. Attempts to achieve 

heat output rates that exceed heater design specifications 

can result in permanent damage to the heater.

IGNITOR

1. 

Fill hopper and clean burn pot.

2. 

Press the “On/Off” button. Make sure the green light 

comes on.

3. 

Adjust the feed rate to the desired setting by pressing 

the “Heat Level Advance” button.

If the fire doesn’t start in 12 minutes, press “On/Off”, wait 

a few minutes, clear the burn pot, and start the procedure 

again.

OPENING DOOR

CAUTION:

•  DO NOT OPERATE YOUR STOVE WITH THE VIEWING 

DOOR OPEN. THE AUGER WILL NOT FEED PELLETS 

UNDER THESE CIRCUMSTANCES AND A SAFETY 

CONCERN MAY ARISE FROM SPARKS OR FUMES 

ENTERING THE ROOM.

•  THE DOOR MUST BE CLOSED AND SEALED DURING 

OPERATION.

If the door is opened while the stove is in operation it must 

be closed within 30 seconds or the stove will shut down. If 

the stove shuts down push the “On/Off” button to re-start 

your stove. The stove will have to fully shut down and turn 

off before you will be able to restart the stove.

ROOM AIR FAN

When starting your stove the Room Air Fan will not come 

on until the stove’s heat exchanger warms up. This usually 

takes about 10 minutes from start-up.

IF STOVE RUNS OUT OF PELLETS

The fire goes out and the auger motor and blowers will run 

until the stove cools. This will take 30 minutes or longer 

depending on the heat remaining in the appliance. After 

the stove components stop running all lights on the display 

will go out and the two digit display will begin flashing “E3”

REFUELLING

WARNING:

•  KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT 

WHEN REFILLING.

•  DO NOT OVERFILL HOPPER.

CAUTION:

•  THE HOPPER AND STOVE TOP WILL BE HOT 

DURING OPERATION; THEREFORE, YOU SHOULD 

ALWAYS USE SOME TYPE OF HAND PROTECTION 

WHEN REFUELING YOUR STOVE. 

•  DO NOT TOUCH THE HOT SURFACES OF THE STOVE. 

EDUCATE ALL CHILDREN ON THE DANGERS OF A 

HIGH-TEMPERATURE STOVE. YOUNG CHILDREN 

SHOULD BE SUPERVISED WHEN THEY ARE IN THE 

SAME ROOM AS THE STOVE.

•  NEVER PLACE YOUR HAND NEAR THE AUGER 

WHILE THE STOVE IS IN OPERATION.

•  WE RECOMMEND THAT YOU NOT LET THE HOPPER 

DROP BELOW 1/4 FULL.

TAMPER WARNING

This wood heater has a manufacturer-set minimum low 

burn  rate  that  must  not  be  altered.  It  is  against  federal 

regulations to alter this setting or otherwise operate this 

wood heater in a manner inconsistent with operating 

instructions in this manual.

SHUTDOWN PROCEDURE

WARNING:

NEVER SHUT DOWN THIS UNIT BY UNPLUGGING IT 

FROM THE POWER SOURCE.

OPERATION INSTRUCTIONS

Summary of Contents for VG60

Page 1: ...or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Fut...

Page 2: ...ration of the Vogelzang VG60 pellet stove This heater meets the 2020 U S Environmental Protection Agency s crib wood emission limits for wood heaters sold after May 15 2020 Under specific EPA test conditions burning Douglas Fir dimensional lumber this heater has been shown to deliver heat at a rate of 8 476 to 20 700 Btu hr This heater achieved a particulate emissions rate of 1 5 g hr when tested ...

Page 3: ..._________________________________________ If no Date of inspection of existing venting system ___________________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in...

Page 4: ...N A POWER SURGE PROTECTOR IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONTOF OR OVERTHE HEATER DO NOT ROUTE THE CORD IN FOOTTRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BURNING FUEL CREATES CARBON MONOXIDE AND CAN BE HAZARDOUS TO YOUR HEALTH I...

Page 5: ...or pad or non combustible surface should be large enough to cover at least the area under the product and 6 153 mm beyond the front and beyond each side of the fuel loading and ash removal openings Floor protection must extend under and 2 51 mm to each side of the chimney tee for an interior vertical installation Canadian Installations require a minimum of 18 458 mm beyond the front of the unit an...

Page 6: ...to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed using a certified ceiling fire stop and rain cap When moving your mobile home all exterior venting must be removed while the mobile home is being relocated After relocation all venting must be reinstalled a...

Page 7: ...e purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit periodic cleaning of the exhaust system 90 degree elbows accumulate fly ash and soot thereby reducing exhaust flow and performance of the stove Each elbow or tee reduces draft potential by 30 to 50 All joints in the vent system must be fastened by at least 3 s...

Page 8: ...ing etc 2 Install a non combustible hearth pad underneath the pellet stove This pad should extend at least 6 152 mm in front of the unit 3 Place the pellet stove approximately 15 381 mm away from the interior wall 4 Locate the center of the exhaust pipe of your unit This point should then be extended to the interior wall of your house Once you have located the center point on the interior wall cut...

Page 9: ...ion you have to be aware of the snowdrift line dead grass and leaves We recommend a 3ft 0 91m minimum vertical rise on the inside or outside of the house The through the wall installation is the least expensive and simplest installation Never terminate the end vent under a deck in an alcove under a window or between two windows We recommend Simpson Dura Vent or Metal Fab kits TYPICAL THROUGH THE W...

Page 10: ...el and the fire will smother out To much air will result in a flame that is overactive or aggressive The flame in this situation is typically very blue at the bottom and resembles a blow torch If this situation continues the fuel in the burn pot will be consumed and the fire will go out Matching the amount of air required for proper combustion to the fuel rate is the primary objective in effective...

Page 11: ... speed can be manually operated by pressing the Draft Fan arrows up or down Draft Fan when pressed the display will show Df A which is automatic Press the arrows again to adjust fan speed When the heater is in the manual mode the optional thermostat will not properly control the unit When adjusting the Draft Fan setting try only 1 setting above or below the heat setting It is better to leave the s...

Page 12: ... the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has been reached and the T Stat no longer requires heat it will reduce to a minimum heat range setting of 1 The unit will not turn completely off Once the room temperature has dropped and the T Stat requir...

Page 13: ...n reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could result in a house fire Do not over fire or use volatile fuels or combustibles doing so may cause a personal and property damage hazards THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY Fac...

Page 14: ... SPARKS OR FUMES ENTERING THE ROOM THE DOOR MUST BE CLOSED AND SEALED DURING OPERATION If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down If the stove shuts down push the On Off button to re start your stove The stove will have to fully shut down and turn off before you will be able to restart the stove ROOM AIR FAN When starting y...

Page 15: ...for more than 30 seconds during operation will cause enough pressure change to activate the air switch shutting the fuel feed off The stove will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodically remove and clean the burn pot and the area inside the burn pot housing In particular it is advisable to clean out the...

Page 16: ...is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repaired To clean the chimney disconnect the vent from the stove FLY ASH This accumulates in the horizontal portion of an exhaust run Though non combustible it may impede the normal exhaust flow It should therefore be periodically removed ASH REMOVAL DISPOSAL CAUTION ALLOW THE...

Page 17: ... the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eight nuts and rope gasket using high temperature silicone to adhere the gasket to the door 6 Never use substitute materials for the glass DO NOT abuse the door glass by striking slamming or similar trauma Do not operate the stove with the glass removed cracked or broken FALL START UP Prior to starting the first fi...

Page 18: ...all outside connections are clear of any obstructions Check the exhaust system clean as needed Check that the pressure switch connection to the firebox is free of ash or clear of obstructions Auger system is jammed or there is a bridging of the fuel in the hopper preventing fuel from flowing into the auger feed system PROBLEM CAUSE Auto Start Igniter fails to ignite the fuel in the burn pot Stove ...

Page 19: ...ete Flashing Off This indicates that the stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat Range Display This indicates that the stove is in the normal run mode and is ramping from the current heat range setting to the target heat range setting Once the...

Page 20: ...20 2021 United States Stove Company 26 34 32 28 29 30 31 27 25 22 21 20 23 24 19 17 18 16 14 15 9 8 7 6 1 4 5 2 3 10 11 12 13 REPAIR PARTS ...

Page 21: ...5 28845 Motor Cover 1 26 28604 Back Panel 1 27 28889 Pressure Switch Bracket 1 28 80549 Vacuum Switch 1 29 80609 High Limit Thermodisc 1 30 80779 Digital Wall Thermostat 1 31 80780 IR Remote 1 32 80462 3 Prong Receptacle 1 33 80461 Power Cord 1 IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING VOGELZANG PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM VOGELZANG USE OF THIRD PARTY...

Page 22: ...ll help to ensure the correct items are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the unit Other information that may be needed would be the part number and part description of the item s in question Part numbers and descriptions can be found in the Repai...

Page 23: ...___ Engineer Name ______________________________________ License No _________________________________________ Company ____________________________________________ Telephone No _______________________________________ Stove Inspected Chimney Swept Items Replaced ______________________________________ Service 02 Date ________________________ Engineer Name ______________________________________ Licens...

Page 24: ...24 2021 United States Stove Company NOTES ...

Page 25: ... 2021 United States Stove Company 25 NOTES ...

Page 26: ...________________ Service de 07 Date _______________________ Nom de l ingénieur __________________________________ N de licence _______________________________________ Compagnie _________________________________________ N de téléphone ____________________________________ Poêle Inspecté Cheminée balayée Articles Remplacé __________________________________ Service de 02 Date _______________________ N...

Page 27: ...areil Lors de la commande de pièces de rechange les informations contenues dans ce manuel vous aideront à vous assurer que les bons articles sont commandés Avant de contacter le service client notez le numéro de modèle et le numéro de série de cet appareil Cette information se trouve sur l étiquette de certification apposée à l arrière de l appareil D autres informations qui pourraient être nécess...

Page 28: ...28846 Support De Moteur De Tarière 1 20 80782 Ventilateur De Combustion 1 21 88308 Joint De Soufflante 1 22 86896 Tube Soudeur 1 23 80607 Allumeur 1 24 40867 Transition Ventilateur 1 25 80781 Moteur De Tarière 1 26 28845 Capot Moteur 1 27 28604 Panneau Arrière 1 28 28889 Support De Commutateur De Pression 1 29 80549 Interrupteur À Vide 1 30 80609 Thermodisque Haute Limite 1 31 80779 Thermostat Mural...

Page 29: ...20 2021 United States Stove Company 26 34 32 28 29 30 31 27 25 22 21 20 23 24 19 17 18 16 14 15 9 8 7 6 1 4 5 2 3 10 11 12 13 PIÈCES DE RECHANGE ...

Page 30: ...ois par seconde Cela indique que le poêle fonctionne normalement et qu une condition de température excessive existe provoquant l arrêt du combustible Indicateur de réglage du niveau de chaleur Heat Range clignotant lentement une fois par seconde Cela indique que le poêle est en condition de réduction essayant d éviter un arrêt dû à une température excessive DÉFAUTS D USINE Pour renvoyer les comma...

Page 31: ...à vis sans fin est bloqué ou il y a une voûte de combustible dans la trémie qui empêche le combustible de s écouler dans le système d approvisionnement à vis sans fin PROBLÈME CAUSE L allumeur automatique n allume pas le combustible dans le pot de combustion Le poêle ne démarre pas un feu quand le bouton ON marche est pressé Mettez le poêle en position OFF arrêt Retirez le combustible non brûlé du...

Page 32: ...du verre en place 3 Tout en portant des gants retirez soigneusement les morceaux de verre détachés du cadre de la porte 4 Remplacez la vitre et le joint en vous assurant que le joint parcourt tout le périmètre du bord du verre 5 Réinstaller le dispositif de retenue et les huit écrous et le joint de corde à l aide de silicone haute température pour faire adhérer le joint à la porte 6 N utilisez jam...

Page 33: ...er la totalité du système avant chaque saison de chauffage Pour nettoyer la cheminée déconnecter l évacuation du poêle CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d évacuation Bien qu elles ne soient pas combustibles elles peuvent gêner le flux normal d évacuation Elles doivent donc être périodiquement éliminées ENLÈVEMENT ET ÉLIMINATION DES CENDRES AVERTISSEMENT LAI...

Page 34: ...voque un changement de pression suffisant pour activer l interrupteur pneumatique qui arrête l alimentation en combustible Le poêle s éteint et la mention E2 s affiche sur l écran à deux chiffres Le poêle doit s arrêter complètement avant de pouvoir être redémarré CHAMBRES INTÉRIEURES Pot de combustion Retirez et nettoyez périodiquement le pot de combustion et la zone à l intérieur du boîtier du p...

Page 35: ...nnement du poêle elle doit être refermée dans les 30 secondes sinon le poêle s éteint Si le poêle s éteint appuyez sur l interrupteur ON OFF pour le redémarrer Le poêle doit être complètement arrêté et débranché avant de pouvoir être redémarré AVERTISSEMENT NE FAITES PAS FONCTIONNER VOTRE POÊLE AVEC LA PORTE VUE OUVERTE LA TARIÈRE N ALIMENTERA PAS DE GRANULÉS DANS CES CIRCONSTANCES ET UN PROBLÈME ...

Page 36: ...formances Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les dégagements d installation de l appareil ou dans l espace requis pour faire le plein et enlever les cendres Cela pourrait provoquer un incendie Ne pas trop brûler ou utiliser des combustibles volatiles ou des combustibles cela pourrait causer des dommages aux personnes et à la propriété Cet appareil n est homolog...

Page 37: ...mme entre le réglage présélectionné de la plage de chaleur désirée 1 à 5 et le réglage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne éteindra le poêle Lorsque la température ambiante souhaitée est atteinte et que le T Stat n a plus besoin de chaleur le réglage de la plage de chauffage minimale est défini sur 1 L unité ne s éteindra pas complètement Une fois que la température amb...

Page 38: ...conformément au réglage du niveau de chaleur Cependant cette vitesse peut être réglée manuellement en appuyant sur les flèches haut et bas du ventilateur de tirage Draft Fan Lorsque le bouton Draft Fan ventilateur de tirage est appuyé l affichage indiquera Df A qui est automatique Appuyez de nouveau sur les flèches pour régler la vitesse du ventilateur Quand le système de chauffage est en mode man...

Page 39: ... peu d air pendant une durée suffisante le pot de combustion se remplira avec trop de combustible et le feu s étouffera Trop d air provoquera une flamme hyperactive ou agressive La flamme dans cette situation est généralement très bleue à la base et ressemble à celle d un chalumeau Si cette situation persiste le combustible dans le pot de combustion sera consumé et le feu s éteindra Faire correspo...

Page 40: ... recommandé que l installation soit plus grand que 3 pieds 0 91 m pour obtenir au dessus de la ligne de congère Cette même installation peut être utilisée si votre chauffe eau est en dessous du niveau du sol en ajoutant simplement la section de nettoyage et tuyau vertical intérieur jusqu à ce que le niveau du sol est atteint Avec cette installation vous devez être conscient de la hauteur de la nei...

Page 41: ...ages de chauffage et annuler votre garantie ECHAPPEMENT HORIZONTALES INSTALLATION 1 Localisez votre poêle à granulés dans un endroit qui répond aux exigences de ce manuel mais dans une zone où il ne gêne pas la charpente de la maison le câblage etc 2 Installez un tampon de foyer non combustible sous le poêle à granulés Ce coussin doit dépasser d au moins 6 po 152 mm en face de l unité 3 Placez le ...

Page 42: ... doit comprendre un té de nettoyage pour permettre la collecte des cendres volantes et pour permettre le nettoyage périodique du système d échappement Les coudes à 90 degrés accumulent les cendres volantes et la suie réduisant ainsi le débit d échappement et les performances du poêle Chaque coude ou té réduit le potentiel de tirage de 30 à 50 Tous les joints du système de ventilation doivent être ...

Page 43: ...ure doit être enlevée pendant le déplacement de la maison mobile Après le déplacement tous les évents doivent être réinstallés et solidement fixés L air extérieur est obligatoire pour l installation d une maison mobile Consultez la section Alimentation en air extérieur et votre revendeur pour l achat Vérifiez auprès de vos responsables locaux du bâtiment car d autres codes peuvent s appliquer EXIG...

Page 44: ...dres La protection du plancher doit s étendre sous et 2 51 mm de chaque côté du té de cheminée pour une installation verticale intérieure Les installations canadiennes nécessitent un minimum de 18 po 458 mm au delà de l avant de l appareil et de 8 po 204 mm au delà de chaque côté de l appareil po mm A Côté à poêle U S A 6 153 CAN 8 204 B De l avant au poêle U S A 6 153 CAN 18 458 DÉGAGEMENTS Votre...

Page 45: ...EZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON ÉLECTRIQUE SOUS DEVANT OU SUR LE POÊLE NE FAITES PAS COURIR LE CORDON ÉLECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE GÉNÈRE DU MONOXYDE DE CARBONE QUI PEUT S AVÉRER DANGEREUX POUR LA SANTÉ EN L ABSENCE D UNE VENTILATION APPROPRIÉE ATTENTION UN DÉTECTEUR DE FUMÉE FONCTIONN...

Page 46: ...non date d inspection du système de ventilation existant _______________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conformément aux instructions d installation Confirmer le bon placement des pièces internes Vérifier la solidité du joint de porte et des joints de porte Confirmer les dégagements aux combustibles selon les instr...

Page 47: ...e tarif réglage le plus bas 1 5 lbs hr Taille de Pellet peut effectuer le taux réel d alimentation en carburant et de brûler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant listé pour de meilleurs résultats Temps de combustion réglage le plus bas 32 hrs approximatif Capacité de la trémie 60 lbs 27 2 kg Spécifications Électriques Note électrique 120 V 60 H...

Page 48: ...les restrictions et les exigences d installation dans votre région NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l intégralité de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut entraîner des dommages matériels des blessures corporelles ou même la mort Une installation incorrecte pourrait annuler votre garantie Co...

Reviews: