background image

4

© 2021 United States Stov

e Company

AVIS DE SÉCURI

• 

SI CE POÊLE N’EST

 PAS INST

ALLÉ CORRECTEMEN

T, 

UN INCENDIE PEUT EN RÉSUL

TER. POUR RÉDUIRE LES 

RISQUES D’INCENDIE, SUIVE

Z LES INSTRUCTIONS 

D’INSTALL

ATION.

• 

ADRESSEZ-VOUS A

UX AUT

ORITÉS L

OCALES DE 

L ’URBANISME 

POUR OBTENIR UN 

PERMIS ET DES 

RENSEIGNEMENTS SUR 

TOUTE A

UTRE RESTRICTION À 

L ’INST

ALLATION 

ET SUR LES EXIGENCES 

D’INSPECTION 

DANS V

OTRE RÉGION.

• 

NE PLA

CEZ AUCUN VÊ

TEMENT OU A

UTRE OBJET 

INFLAMM

ABLE SUR OU PRÈS DU POÊLE.

• 

N’UTILISEZ JAM

AIS D’ESSENCE, DE COMBUSTIBLE 

À LAN

TERNE DE 

TYPE 

ESSENCE, DE KÉROSÈNE, 

D’ESSENCE D’

ALLUME-FEU 

OU D’AUTRES LIQUIDES 

SIMILAIRES POUR ALL

UMER OU RAVIVER 

LE FEU DANS 

CE POÊLE. GARDEZ TOUS CES LIQUIDES ÉL

OIGNÉS DU 

POÊLE LORSQU’IL EST

 EN MARCHE.

• 

CET APP

AREIL EST UN APP

AREIL DE CHA

UFFAGE 

AUT

ONOME. IL N’EST

 PAS CON

ÇU POUR ÊTRE RELIÉ 

À 

DES CONDUI

TS DE DISTRIBUTION D’

AIR. CE N’EST P

AS 

UN FOURNEAU.

• 

INSTALLER L

'ÉVENT A

UX DÉGA

GEMENTS SPÉCIFIÉS 

PAR 

LE FABRICAN

T DE L

'ÉVENT.

• 

N’INSTALLEZ P

AS DE REGISTRE DE TIRA

GE SUR LE 

SYSTÈME D’ÉV

ACU

ATION DE CE

T APP

AREIL. 

• 

CE POÊLE DOIT Ê

TRE RÉGULIÈREMEN

T EN

TRETENU 

ET NE

TTO

YÉ (V

OIR LA SEC

TION « ENTRE

TIEN »). LE 

DÉFAUT

 D’ENTR

ETIEN DU POÊLE 

PEUT EN

TRAÎNER UN 

FONCTIONNEMEN

T IN

APPROPRIÉ ET D

ANGEREUX.

• 

UN DISJONC

TEUR DOI

T Ê

TRE INSTALLÉ. CE

T APP

AREIL 

DOIT Ê

TRE BRANCHÉ SUR UNE 

PRISE MURALE 

AVEC 

TERRE DE 110-120 V, 

60  Z. N’UTILISEZ 

PAS 

D’AD

APTATEUR DE PRISE 

ET NE 

COUPEZ PAS L

A FICHE 

DE TERRE. N’

ACHEMINEZ 

PAS LE CORDON 

ÉLECTRIQUE 

SOUS, DEV

ANT OU SUR LE 

POÊLE. NE F

AITES P

AS 

COURIR LE CORDON 

ÉLECTRIQUE D

ANS LES ZONES DE 

PASSA

GE ET NE LE COINCEZ P

AS SOUS LES MEUBLES.

ATTEN

TION:

• 

UN DÉTEC

TEUR DE FUMÉE FONC

TIONNEL DOI

T Ê

TRE 

INSTALLÉ D

ANS LA PIÈCE OÙ SE 

TROUVE LE POÊLE.

• 

INSTALLEZ UN DÉ

TECTEUR DE FUMÉE 

À CHA

QUE ÉTA

GE 

DE VO

TRE M

AISON; EN CAS D’INCENDIE 

ACCIDEN

TEL 

DÛ À N’IMPORTE QUELLE 

CAUSE, 

CE DISPOSITIF PEUT 

LAISSER LE 

TEMPS DE S’ÉCHAPPER.

• 

LE DÉTEC

TEUR DE FUMÉE DOI

T Ê

TRE INST

ALLÉ À AU 

MOINS 15 

PIEDS (4,57 M) 

DE L ’APP

AREIL AFIN D’ÉVITER 

QU’IL NE SE DÉCLENCHE INUTILEMENT L

ORS DU 

RECHARGEMEN

T DU POÊLE.

ATTEN

TION:

ATTEN

TION: LA COMBUSTION 

DU COMBUSTIBLE GÉNÈRE 

DU  MONO

XYDE DE CARBONE QUI PEUT

 S’AVÉRER 

DANGEREUX 

POUR LA SAN

TÉ EN 

L ’ABSENCE 

D’UNE 

VENTIL

ATION APPROPRIÉE.

ATTEN

TION:

• 

L ’UTILISA

TION D’AIR EXTÉRIEUR 

N’EST P

AS NÉCESSAIRE 

POUR CET APP

AREIL.

• 

NE DÉBRANCHEZ PAS LE POÊLE SI V

OUS SOUPÇONNEZ 

UN DY

SFONCTIONNEMEN

T. PL

ACEZ 

LE CON

TAC

TEUR 

ON/OFF SUR « 

OFF » PUIS 

PRENEZ CON

TAC

T A

VEC LE 

CONCESSIONNAIRE.

• 

LE POÊLE NE FONCTIONNE 

PAS PEND

ANT LES COUPURES 

DE COURAN

T. E

N CAS DE PANNE 

DE COURANT, 

VEILLEZ 

AUX ÉM

ANATIONS 

DE FUMÉE DU 

POÊLE ET

 OUVREZ UNE 

FENÊTRE SI L

A FUMÉE SE RÉPAND D

ANS LA PIÈCE.

• 

N’OBSTRUEZ JAM

AIS LA CIRCUL

ATION 

DE L ’AIR 

DES 

GRILLES D’AÉRA

TION OUVERTES DE L

’APP

AREIL.

US Stov

e recommande for

tement que v

otre 

poêle soit 

installé 

par un 

technicien 

qualifié NFI 

(US) ou 

WETT

 (Canada). 

Pour 

trouv

er l’installateur qualifié le plus proche, accédez à:

https://nficer

tified.org,

https://www

.wettinc.ca/

INSTALL

ATIO

N INCO

RRECT

E

L ’utilisation 

d’autr

es composants 

autres 

que ceux 

indiqués dans 

le pr

ésent document pourr

ait causer des 

blessures 

corporelles, 

des dommages au r

adiateur et 

annuler votr

e gar

antie. Le 

fabricant ne ser

a pas tenu 

responsable 

des dommages causés 

par le 

dysfonctionnement d’un 

poêle en 

raison 

d’une ventilation 

ou d’une installation incorrecte.

PROTEC

TION

 DES

 SOLS

Cet appar

eil de chauffage 

doit avoir un pr

otecteur de plancher 

incombustible (pr

otection contr

e les 

braises 

UL1618) installé 

en 

dessous si le plancher est en matériau combustible.

É.-U.:

 Le tapis de 

sol ou la 

surface non 

combustible doit êtr

suffisamment gr

and pour 

couvrir au 

moins la 

zone 

sous le 

produit 

et 6 

po (152 

mm) 

au-delà de 

l’av

ant et 

au-delà de 

chaque côté 

des ouv

ertur

es de 

chargement 

de combustible 

et de 

retr

ait des 

INSTALL

ATIO

N

All manuals and user guides at all-guides.com

Summary of Contents for VG5770

Page 1: ... about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Future Reference CAL...

Page 2: ...on of the Vogelzang VG5770 wood heater This heater meets the 2020 US Environmental Protection Agency s wood pellet emissions limits for wood heaters sold after May 15 2020 Under specific test conditions this heater has been shown to deliver heat at rates ranging from 9 218 to 18 619 Btu hr This heater achieved a particulate emissions rate of 0 85 g hr and an efficiency of 70 SPECIFICATIONS For Cus...

Page 3: ...__________________ If no Date of inspection of existing venting system ___________________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in this manual Check the ...

Page 4: ... BE INSTALLED IN THE SAME ROOM AS THIS PRODUCT INSTALL A SMOKE DETECTOR ON EACH FLOOR OF YOUR HOME INCASE OF ACCIDENTAL FIRE FROM ANY CAUSE IT CAN PROVIDE TIME FOR ESCAPE THE SMOKE DETECTOR MUST BE INSTALLED AT LEAST 15 FEET 4 57 M FROM THE APPLIANCE IN ORDER TO PREVENT UNDUE TRIGGERING OF THE DETECTOR WHEN RELOADING CAUTION BURNING FUEL CREATES CARBON MONOXIDE AND CAN BE HAZARDOUS TO YOUR HEALTH ...

Page 5: ...clearance to combustibles may only be done by means approved by a regulatory authority E F G E F G H H H H TABLE 1 CLEARANCES in mm PARALLEL E Back wall to unit 3 76 F Sidewall to flue 11 280 G Sidewall to top edge of unit 8 203 CORNER H Adjacent wall to unit 8 203 OUTSIDE AIR SUPPLY OPTIONAL UNLESS INSTALLING IN A MOBILE HOME ATTENTION DO NOT VENT UNDER ANY PORCH DECK AWNING OR IN ANY SEMI ENCLOS...

Page 6: ...ALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT The following installation guidelines must be followed to ensure conformity with both the safety listing of this stove and to local building codes Do not use makeshift methods or compromise in the installation IMPORTANT THIS UNIT IS EQUIPPED WITH A NEGATIVE DRAFT SYSTEM THAT PULLS AIR THROUGH THE BURN POT AND PUSHES THE EXHAUST OUT OF TH...

Page 7: ...other means to maintain the vapor barrier between the exterior and the interior of the home Vent surfaces can get hot enough to cause burns if touched by children Noncombustible shielding or guards may be required PELLET VENT TERMINATION Do not terminate the vent in an enclosed or semi enclosed area such as carport garage attic crawl space under a sun deck or porch narrow walkway or any other loca...

Page 8: ...e This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to be aware of the snowdrift line dead grass and leaves We recommend a 3ft 0 91m minimum vertical rise on the inside or outside of the house The through the wall installation is the least expensive an...

Page 9: ...at Separate LEDs to the left of the two digit display indicate the mode of operation Manual or T Stat The stove has to be in normal operation to be switched from Manual to T Stat mode Manual mode operates according to the 5 set levels of feed on the bar graph from heat range 1 to heat range 5 T Stat mode works as follows The stove has a built in Thermostat into the controls of the appliance The te...

Page 10: ...r 1 long Longer or thicker pellets sometimes bridge the auger flights which prevents proper pellet feed Burning wood in forms other than pellets is not permitted It will violate the building codes for which the stove has been approved and will void all warranties The design incorporates automatic feed of the pellet fuel into the fire at a carefully prescribed rate Any additional fuel introduced by...

Page 11: ...he rapid buildup of creosote inside your stove and chimney You should adjust the damper based on the fire s appearance A low reddish dirty fire can be improved by turning the dampener slightly to the right A blow torch fire can be improved by closing the damper a bit On higher feed rates the damper should be open more Through trial and error you will find the best setting Consult your dealer if yo...

Page 12: ...r stove On other units the thermodisc has no reset button and will reset itself once the stove has cooled The manufacturer recommends that you call your dealer if this occurs as this may indicate a more serious problem A service call may be required 2 If the combustion blower fails an air pressure switch will automatically shut down the auger NOTE Opening the stove door for more than 30 seconds du...

Page 13: ...cleaned and if necessary repaired To clean the chimney disconnect the vent from the stove FLY ASH This accumulates in the horizontal portion of an exhaust run Though non combustible it may impede the normal exhaust flow It should therefore be periodically removed ASH REMOVAL DISPOSAL CAUTION ALLOW THE STOVE TO COOL BEFORE PERFORMING ANY MAINTENANCE OR CLEANING ASHES MUST BE DISPOSED IN A METAL CON...

Page 14: ...o operate the unit with broken glass Replacement glass may be purchased from your U S Stove dealer If glass is broken follow these removal procedures 1 Once the heater has cooled remove the door from the heater 2 Remove the rope gasket from the door along with the screws holding the glass retainer in place and the glass retainer 3 While wearing leather gloves or any other gloves suitable for handl...

Page 15: ...The information in this owner s manual is specific to your unit When ordering replacement parts the information in this manual will help to ensure the correct items are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the unit Other information that may be neede...

Page 16: ...el other than wood pellets is being burned in the stove This pellet stove is designed and tested to use wood pellets Check for signs of fuel other than wood pellets No other types of fuel have been approved for this pellet stove If there are signs of other types of fuel being used stop using them immediately Power surge or brown out situation A power surge spike or voltage drop could cause the hig...

Page 17: ...med on something If the motor will not turn the motor is bad The Proof of Fire POF thermodisc has malfunctioned Temporarily bypass the POF thermodisc by disconnecting the two wires and connecting them with a short piece of wire Then plug the stove back up If the stove comes on and works you need to replace the POF thermodisc This is for testing only DO NOT LEAVE THE THERMODISC BYPASSED Your blower...

Page 18: ...ft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing Next remove the two nuts that hold the top auger biscuit in Then rotate the bottom end of the auger shaft up towards you until you can lift the shaft out of the stove After you have removed the shaft inspect it for bent flights burrs or broken welds Remove any foreign material tha...

Page 19: ... foil tape Also make sure the square to round adapter piece on the combustion blower has been properly sealed with the same RTV The gasket on the combustion blower has gone bad Inspect both gaskets on the combustion blower to make sure they are in good shape Because it is a wood burning device your pellet heater may emit a faint wood burning odor If this increases beyond normal or if you notice an...

Page 20: ...board If the fuse is good the wires and connectors check out good and the high limit switch did not trip test for power going to the auger motor If there is not a full current going to the auger motor when the fuel feed light is on you have a bad control board GLASS SOOT S UP AT A VERY FAST RATE FLAME IS LAZY DARK AND HAS BLACK TIPS AFTER STOVE HAS BEEN ON FOR A WHILE THE BURNPOT OVERFILLS Possibl...

Page 21: ... 2021 United States Stove Company 21 CORRECT WRONG ENSURE THE WIRES ARE CONNECTED TO THE BOTTOM TWO PRONGS OF THE HOPPER SWITCH AS SHOWN WIRING DIAGRAM All manuals and user guides at all guides com ...

Page 22: ...1 United States Stove Company 1 2 3 4 8 9 15 17 19 34 20 21 22 23 27 28 29 30 35 36 37 38 40 41 24 25 5 6 7 43 18 26 33 14 1 16 18 39 42 12 13 31 32 REPAIR PARTS All manuals and user guides at all guides com ...

Page 23: ...mp 1 33 88176 Insulating Blanket 1 34 88177 Gasket Ash Clean out 2 35 88175 Gasket T disc 2 36 80601 T Disc Room Air 1 37 88167 Gasket Room Blower 1 38 80604 Igniter 1 39 80622 Room Blower 1 40 80549 Vacuum Switch 1 41 88166 Gasket Exhaust Blower 1 42 80602 Exhaust Blower 1 43 892199 Housing PCBA Controller 1 IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING ORIGINAL VOGELZANG PARTS ...

Page 24: ...________________________________ License No _________________________________________ Company ____________________________________________ Telephone No _______________________________________ Stove Inspected Chimney Swept Items Replaced ______________________________________ Service 02 Date ________________________ Engineer Name ______________________________________ License No ___________________...

Page 25: ... de 07 Date _______________________ Nom de l ingénieur __________________________________ N de licence _______________________________________ Compagnie _________________________________________ N de téléphone ____________________________________ Poêle Inspecté Cheminée balayée Articles Remplacé __________________________________ Service de 02 Date _______________________ Nom de l ingénieur ______...

Page 26: ... 88177 Joint Ash Clean out 2 35 88175 Joint T disque 2 36 80601 T Disc Chambre Air 1 37 88167 Joint Chambre Blower 1 38 80604 Igniter 1 39 80622 Chambre Blower 1 40 80549 Interrupteur à vide 1 41 88166 Joint d échappement Blower 1 42 80602 échappement Blower 1 43 892199 Logement contrôleur PCBA 1 Clé Partie Description Qté 1 40586 Nourrissez Door 1 2 88066 3 4 Corde ronde Joint Noire 55 po 3 89219...

Page 27: ...United States Stove Company 1 2 3 4 8 9 15 17 19 34 20 21 22 23 27 28 29 30 35 36 37 38 40 41 24 25 5 6 7 43 18 26 33 14 1 16 18 39 42 12 13 31 32 SCHÉMA DES PIÈCES All manuals and user guides at all guides com ...

Page 28: ...tates Stove Company 21 CORRECT FAUX ASSUREZ VOUS QUE LES FILS SONT CONNECTÉS AUX DEUX BROCHES INFÉRIEURES DE L INTERRUPTEUR DE LA TRÉMIE COMME ILLUSTRÉ SCHÉMA DE CÂBLAGE All manuals and user guides at all guides com ...

Page 29: ...ige du registre d admission Lorsqu on déplace la tige du registre la plaque doit se déplacer avec elle Blocage du conduit d admission d air Inspecter visuellement le conduit d admission d air qui entre dans le pot de combustion en recherchant des corps étrangers Dysfonctionnement de la carte de circuit imprimé Mesurez le délai d allumage du témoin d alimentation en combustible pour chaque réglage ...

Page 30: ...Fil débranché ou connecteur desserré Vérifiez tous les fils et connecteurs branchés sur le moteur de tarière l interrupteur de surchauffe et le connecteur Molex Tableau de commande défectueux Si le fusible est bon les fils et connecteurs bien raccordés et que l interrupteur de surchauffe ne s est pas déclenché testez la tension qui arrive au moteur de tarière En l absence de tension nominale arriv...

Page 31: ...ébranchez le poêle avant toute chose quand c est possible Il y a une fuite dans le système de conduit d évacuation Inspectez tous les raccords de tuyaux d évacuation Assurez vous qu ils soient tous scellés avec du silicone RTV supportant une température de 500 F 260 C ou plus En outre scellez les joints avec du ruban métallique UL 181 AP Vérifiez également que la pièce d adaptation carré cercle du...

Page 32: ...e est coincé Commencez par vider la trémie Puis retirez le moteur de la tarière en retirant la goupille de la tarière Retirez la plaque d inspection de l arbre de la tarière dans la trémie pour pouvoir examiner l arbre de la tarière Soulevez légèrement l arbre de la tarière de sorte que l extrémité de l arbre sorte du manchon inférieur de tarière Retirez ensuite les deux écrous qui tiennent la pas...

Page 33: ... ne tourne pas il est défectueux Le thermodisque de détection de feu POF a mal fonctionné Contournez temporairement le thermodisque POF en débranchant les deux fils et en les raccordant avec un petit morceau de fil Puis rebranchez le poêle Si le poêle s allume et fonctionne vous devez remplacer le thermodisque POF Cette manœuvre est réservée aux tests NE LAISSEZ PAS LE THERMODISQUE HORS CIRCUIT Si...

Page 34: ... cas essayez d utiliser un réglage de chauffage inférieur Un autre combustible que les granulés de bois est brûlé dans le poêle Ce poêle à granulés a été conçu et testé pour brûler des granulés de bois Recherchez la présence de combustibles autre que des granulés de bois Aucun autre type de combustible n a été approuvé pour ce poêle à granulés En présence de signes d utilisation d autres types de ...

Page 35: ...ssé Seul le verre céramique à haute température de la taille et de l épaisseur appropriées peut être utilisé NE PAS substituer les matériaux alternatifs pour le verre Contactez votre revendeur agréé pour obtenir ce verre 3 Réinstallez le nouveau verre en remontant les fixations et les vis veillez à ne pas trop serrer les vis car cela pourrait endommager le verre NE PAS abuser du verre de la porte ...

Page 36: ...s doivent donc être périodiquement éliminées ENLÈVEMENT ET ÉLIMINATION DES CENDRES AVERTISSEMENT LAISSEZ LE POÊLE REFROIDIR AVANT D EFFECTUER TOUT ENTRETIEN OU NETTOYAGE LES CENDRES DOIVENT ÊTRE ÉVACUÉES DANS UN RÉCIPIENT MÉTALLIQUE DOTÉ D UN COUVERCLE HERMÉTIQUE LE RÉCIPIENT À CENDRES FERMÉ DOIT ÊTRE DÉPOSÉ SUR UNE SURFACE NON COMBUSTIBLE OU SUR LE SOL BIEN À L ÉCART DE TOUTE MATIÈRE COMBUSTIBLE ...

Page 37: ...us recommande de vous adresser au revendeur si cela se produit car cela peut indiquer un problème plus grave Il peut s avérer nécessaire d appeler le service de réparation 2 En cas de défaillance du ventilateur de combustion un interrupteur pneumatique interrompt automatiquement la tarière REMARQUE L ouverture de la porte du poêle pendant plus de 30 secondes pendant le fonctionnement provoque un c...

Page 38: ...lés et des débits d alimentation des granulés Il vous permet d améliorer l efficacité de votre poêle Fournir un air de combustion correct réduira la fréquence de nettoyage de votre porte vitrée et empêchera l accumulation rapide de créosote à l intérieur de votre poêle et de votre cheminée Vous devez ajuster le registre en fonction de l apparence du feu Un feu bas rougeâtre et sale peut être améli...

Page 39: ...arière ce qui empêche une bonne alimentation en granulés Il est interdit de brûler du bois sous d autres formes que des granulés Il s agirait d une violation des codes du bâtiment pour lesquels le poêle a été approuvé et cela annulerait toutes les garanties La conception du poêle intègre l alimentation automatique des granulés dans le feu selon un rythme soigneusement calculé Un autre combustible ...

Page 40: ... commandé par un Thermostat Des diodes distinctes à gauche de l écran à deux chiffres indiquent le mode de fonctionnement Manuel ou T stat Le poêle doit être en mode de fonctionnement normal pour pouvoir passer du mode Manuel au mode T Stat Le mode Manuel fonctionne conformément aux 5 niveaux de réglage d alimentation sur le diagramme du niveau de chauffage 1 au niveau 5 Le mode T stat fonctionne ...

Page 41: ...l est recommandé que la sortie de l installation se trouve à plus de 3 pi 0 91 m pour échapper à la ligne de congère Cette même installation peut être utilisée si le poêle se trouve sous le niveau du sol en ajoutant simplement la section de nettoyage et un tuyau vertical à l intérieur jusqu au niveau du sol Avec cette installation il faut tenir compte de la ligne de congère des herbes et des feuil...

Page 42: ...rds du système d évacuation doivent être fixés par au moins 3 vis et scellés avec une colle de silicone RTV haute température pour les rendre étanches à l air La zone où le conduit d évacuation sort de la maison doit être scellée au silicone ou un autre moyen pour préserver le pare vapeur entre l extérieur et l intérieur de la maison Les surfaces d évacuation peuvent devenir assez chaudes pour pro...

Page 43: ...CUATIONS NE RELIEZ PAS L ÉVACUATION POUR POÊLE À GRANULÉS À UNE ÉVACUATION UTILISÉE POUR UN AUTRE APPAREIL OU UN AUTRE POÊLE N INSTALLEZ PAS DE REGISTRE DE TIRAGE SUR LE SYSTÈME D ÉVACUATION DE CET APPAREIL Les directives d installation ci dessous doivent être respectées pour garantir la conformité tant avec la liste de sécurité de ce poêle qu avec les codes de construction locaux Ne pas recourir ...

Page 44: ...ut être effectuée que par des moyens approuvés par une autorité réglementaire E F G E F G H H H H TABLE 1 CLEARANCES po mm Parallèle E Mur arrière à l appareil 3 76 F Mur latéral au conduit de fumée 11 280 G Mur latéral au bord supérieur de l appareil 8 203 Coin H Mur adjacent à l appareil 8 203 ALIMENTATION EN AIR EXTÉRIEUR EN OPTION SAUF SI INSTALLÉ DANS UNE MAISON MOBILE ATTENTION NE PAS VENTIL...

Page 45: ... CAUSE CE DISPOSITIF PEUT LAISSER LE TEMPS DE S ÉCHAPPER LE DÉTECTEUR DE FUMÉE DOIT ÊTRE INSTALLÉ À AU MOINS 15 PIEDS 4 57 M DE L APPAREIL AFIN D ÉVITER QU IL NE SE DÉCLENCHE INUTILEMENT LORS DU RECHARGEMENT DU POÊLE ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE GÉNÈRE DU MONOXYDE DE CARBONE QUI PEUT S AVÉRER DANGEREUX POUR LA SANTÉ EN L ABSENCE D UNE VENTILATION APPROPRIÉE ATTENTION L UTILISAT...

Page 46: ...u système de ventilation existant _______________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conformément aux instructions d installation Confirmer le bon placement des pièces internes Vérifier la solidité du joint de porte et des joints de porte Confirmer les dégagements aux combustibles selon les instructions d installation ...

Page 47: ... appareils de chauffage au bois Vogelzang VG5770 Ce poêle respecte les limites d émission de pellets de bois imposées par la US Environmental Protection Agency en 2020 pour les poêles à bois vendus après le 15 mai 2020 Dans des conditions de test spécifiques il a été démontré que cet appareil produisait de la chaleur à des taux allant de 9 218 à 18 619 Btu h Cet appareil de chauffage a atteint un ...

Page 48: ...es exigences d installation dans votre région NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l intégralité de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut entraîner des dommages matériels des blessures corporelles ou même la mort Une installation incorrecte pourrait annuler votre garantie Conservez ces instructi...

Reviews: