VGZ-018 / 051809.0
NORSEMAN™ 1500/2500 FuRNAcE
/
Page 7
locAtiNg FURNAcE continued…
Fig. 3 – Minimum plenum Clearances from Combustible Materials
wARNINg: RISk OF FIRE
• DO NOT STORE FUEL, FLAm-
mABLE LIqUIDS OR OThER
COmBUSTIBLE mATERIALS
TOO CLOSE TO ThE UNIT.
• Keep furnishings and
OThER COmBUSTIBLE mATERI-
ALS OUTSIDE OF CLEARANCE
DImENSIONS mARkED ON
FURNACE.
• Before firing furnace,
SLIDE FIREBRICkS TOwARDS
REAR SO NO gAPS REmAIN
BETwEEN BRICkS. DO NOT
OPERATE FURNACE wITh
CRACkED OR mISSINg FIRE
BRICkS.
tools & MAtERiAls REqUiRED FoR AssEMblY
AND iNstAllAtioN
TOOLS REqUIRED
Safety Glasses
Gloves
Pencil
6 ft. Tape Measure
Tin Snips
Sabre Saw
Drill
1/8” dia. Drill Bit (for sheet metal screws)
Screwdrivers (Phillips & slotted)
6mm Socket with Driver
10mm Socket with Driver
10mm open end box wrench
7/16” box wrench
mATERIALS REqUIRED
NotE: the following items are Not included with
your furnace:
chimney connection:
6” da. minimum 24 MSG black or 26 MSG blue steel
straight furnace pipe, elbow(s), collar and thimble (as
required).
6˝ Barometric Draft Regulator (optional)
8˝ Round Butterfly Anti-Backdraft Damper
(2 required – for parallel installation only)
Plenum & Duct Work with min. temperature rating of
250° F (as required).
chimney: Existing 6” Lined Masonry chimney
or 6” Inside Dia. Listed Type HT chimney.
1/2” Sheet Metal Screws
Electrical Wiring: 16 ga. AWG copper with 90° c min.
DO NOT use aluminum wire or connectors.
1/2˝ conduit & connectors
Furnace cement (manufacturer recommends Rutland
code 78 or equivalent)