51
3.12 Guard limits
Allows the welding process to be controlled by setting warning
limits
and guard limits
for the
main measurable parameters :
Welding current
Welding voltage
Enter set-up by pressing the encoder button for at least 5 sec-
onds.
Select the required parameter (801).
Enter the “Guard limits” screen by pressing the encoder button.
Select the required parameter by pressing button (1)
.
Select the method of setting the guard limits by pressing button
(2)
.
Absolute value
%
Percentage value
7 Warning limits line
8 Alarm limits line
9 Minimum levels column
10 Maximum levels column
Select the required box by pressing the encoder key (the select-
ed box is displayed with reverse contrast).
Adjust the level of the selected limit by rotating the encoder.
Save and exit the current screen by pressing button (4)
.
Passing one of the warning limits causes a visual signal to appear
on the control panel.
Passing one of the alarm limits causes a visual signal to appear
on the control panel and the immediate blockage of the weld-
ing operations.
It is possible to set start and end of welding filters to prevent
error signals during the striking and extinction of the arc (consult
the “Set up” section - Parameters 802-803-804).
3.13 Alarms screen
Allows the intervention of an alarm to be indicated and provides
the most important indications for the solution of any problem
encountered.
1
Alarm icon
2
Alarm code
3
Alarm type
Alarm codes
E01, E02 Temperature alarm
It is advisable not to switch off the equipment while the alarm
is on; the internal fan will thus keep operating and will help to
cool the overheated parts.
E07
Wire feed motor supply alarm
E08
Blocked motor alarm
E10
Power module alarm
E13
Communication alarm
Summary of Contents for Bohler URANOS 2700 MTE
Page 94: ...94 ...
Page 244: ...244 ...
Page 274: ...274 ...
Page 304: ...304 ...
Page 334: ...334 ...
Page 366: ...366 ...
Page 371: ...371 ...
Page 375: ...375 ...
Page 376: ...376 07 01 337 SL 4R 4T 11A 11B 11C 22 ...
Page 379: ...379 ...
Page 380: ...380 STANDARD U D VERSION OPTIONAL PUSH PULL VERSION ...
Page 381: ......
Page 382: ...voestalpine Böhler Welding www voestalpine com welding ...