Vibration Measurement Instruments
Measuring Bearing Condition
The value of the BC measurement is shown at the top. A bar on the right of the
value indicates the measurement stability.
On the lower part of the screen there are details regarding:
• Transducer used
• Frequency range
• Averaging type
During live measurements you can press:
•
Change detection F1
Change detection type, RMS, Peak or Peak-Peak.
•
Settings F3
Enter the settings menu.
Bearing Condition settings
The following parameters can be set on bearing condition settings:
•
Detection
RMS, Peak or Peak-Peak
•
Frequency range Hz
500-6400, 1000-25000, 2000-25000 or 3000-25000 Hz
•
Averaging
Disabled, Linear or smart
•
Number of Averages
1, 2, 4, 8, 16, 32
•
Set Default F3
Reset settings to default
35