DESIGNATION KEY
100 PRIM
DC X
A.
Colour:
Additional options:
_: White
V: cord switch
T: overrun switch
TH: humidity sensor and overrun switch
TP: motion sensor and overrun switch
DC: DC motor
Nozzle diameter, mm
ASSEMBLY
The fan is designed for ceiling or wall mounting for ventilation in a ventilation shaft or in a ventilation pipe with
the appropriate diameter (Fig. 2).
The installation of the fan with a direct air outlet upwards is not permitted (Fig. 2).
Installation steps of the fan:
Step 1.
Disconnect the device from the power supply and ensure that the power is switched off (Fig. 3).
Step 2.
Route the power cable to the ventilation opening (Fig. 4).
Step 3.
Remove the cover from the fan. Then remove the cover from the printed circuit board (Fig. 5).
Step 4.
Mark and drill the mounting holes and mount the fan (Fig. 6-8).
Step 5.
Connect the fan to the power supply in accordance with the connection diagram (Fig. 12).
Step 6.
Put the protective cover (Fig. 9) and the design cover (Fig. 10) back on the fan housing.
Step 7.
Reconnect the power supply to the fan (Fig. 11).
Designations of the terminals on the connection diagrams:
L:
Phase (only for electrical network 220-240 V)
N:
Zero (only for 220-240 V electrical network)
S:
external switch
QF:
Circuit breaker
LT (ST):
Control chain of the timer
7th
Summary of Contents for 100 PRIM
Page 1: ...DE AXIAL FAN operating manual 100 PRIM www vlano de ...
Page 14: ...DE 108 158 136 81 ø99 1 2 14th ...
Page 15: ...DE LN A QF OUT 3rd 4th 5 6th 7th 8th A OUT 9 10 11 15th ...
Page 16: ...DE QF S LT L N 1 2 3 L N 12th 13 LN A QF OUT 14th 15th A OUT 16 17th 16 ...
Page 17: ...DE 17th ...
Page 18: ...DE 18th ...
Page 20: ...Acceptance report V T 100 PRIM DC TP TH The fan is recognized as operational VLN162DE 03 ...