SUPREMA 2001 - OPERATION & SERVICE MANUAL
Page 6 of 60
July 6, 2001
Suprema 2001 - Operation & Service
REMOVING SHIPPING MATERIALS
2.
Lift and place the coffee maker onto your workbench.
WARNING:
Never lift the machine by placing your hand underneath the front door. It is
not designed to support the weight of the machine, and serious personal
injury and/or damage to the unit may occur.
3.
Open the outer and inner doors.
a)
There are two sets of keys attached to an envelope on the service cord.
The keys numbered 8625 are for the outer door. The keys numbered 8645
are for the inner door.
4.
Remove all the shipping tape.
a)
Shipping tape is found in the following areas: Valve cover, Service cord,
Brewer spout, Cup Trays.
WARNING:
Do not connect the service cord to the wall outlet at this point as more
adjustments are still required to the machine.
CONNECTIONS AND ADJUSTMENTS
When the water tank is drained after testing at the factory, it is possible for the element
may remain hot for a short while afterwards and trigger the thermal cut-off switch.
5.
Reset the thermal cut-off switch.
a)
Remove the valve cover (figure 1) on
the front of the hot water tank.
b)
Remove the plastic wing-nut securing
the water tank access panel to the top
of the machine.
c)
Remove the water tank access panel.
d)
Press the “
reset
” button on the
thermal cut-off switch (figure 2).
6.
Re-install the water tank access panel,
and the valve cover.
Figure 1 - Remove valve cover.
Figure 2 - Reset the thermal cut-off switch.