Fault Finding
Qualified personnel must only carry out any servicing.
Machine must be removed from electrical supply before any servicing.
Vizu Auto Breader VI005AB
Problem
Probable Cause
Solution
1. Count down timer will
not illuminate.
Not plugged in
Not switch ‘ON’ at plug.
Check machine switch is
‘ON’.
Check wall switch is ’ON’
Press Emergency Stop to
reset
2. Breader does not
function.
Emergency switch
accidentally pressed.
Defective ‘ON / OFF’ switch.
Fuse in plug faulty
Loose / broken connection.
Check external currant
breaker is ‘ON/IN’ at main
supply board.
Check fuse in 3 pin plug
Check all connections
Tighten or replace switch
connectors or wiring.
Replace switch
Replace motor
3. Count down timer
illuminated-motor does not
work
Start switch disconnected.
Start switch faulty/broken.
Transformer/rectifier broken
or disconnected
Motor burnt out
Check connections on
reset switch.
Replace switch.
Check connections on
rectifier& transformer
Replace motor
Summary of Contents for Auto Breader
Page 8: ...Wiring Diagram...
Page 9: ...Exploded Diagram...
Page 10: ...Exploded Diagram...
Page 11: ...Exploded Diagram...
Page 18: ......