INSTALLATION
ATTENTION
: Handle the equipment with care. Damage of the mating surface of magnet or armature
plate may reduce locking efficiency.
The lock should be installed inside the building according to directions on Figures
1-3
.
The armature plate is to be fixed on the door. The electromagnet is to be fixed on the door frame
opposite to the armature plate. Electromagnet work surface is shown on Figure
4
.
To ensure maximum holding force the armature plate should be fixed close to the door edge considering
electromagnet installation.
Note: Mounting marking is more convenient to perform when the door is closed.
Installation order:
1
. Make holes for the armature plate and guide pin.
2
. Fix the armature plate on the inner door-side using mounting kit (Figure
1
).
Leave 4..5mm clearance between the plate and door surface.
3
. Fix the plate bar (angle bar) on the door frame using screws (1) (Figures
2
,
3
).
Leave the screws loose for further plate bar (angle bar) adjustment.
4
. Fix the electromagnet on the plate bar (angle bar) using screws (3).
5
. Adjust the electromagnet with plate bar (angle bar) to ensure close fitting of the electromag
net work surface to the armature plate.
6
. Remove the electromagnet off the plate bar (angle bar).
7
. Tighten the screws (1, 2) to fix the plate bar (angle bar) on the door frame.
8
. Fix the electromagnet on the plate bar (angle bar).
CONNECTION AND FUNCTIONAL CHECK
Lock terminals have no polarity. The example of wiring diagram is given on Figure
5
. Requirements for
wires and more wiring examples are given in the controlling device operating instruction.
The controlling device can be a doorstation, control unit, TM- or RF-keys controller etc. Program lock
type in the controlling device - electromagnetic- and its unlocked state duration (if the functions are
supported) following the corresponding operating instruction. The lock is released when the voltage across its
terminals is off.
After installation and wiring complete, check all the connections.
Switch the power on. The electromagnet attracts the armature plate.
The door is locked. Check if locking is firm.
Perform unlocking according to the controlling device operating instruction.
Check if the electromagnet releases the armature plate.