SOLUTIONS TO COMMON ISSUES 

Issue: Compressor inoperable. 

Solution 1: Check all switches to make sure they are ON. 
Solution 2: Check the fuse; if blown, disconnect compressor from power and replace the fuse. 
Solution 3: Allow compressor to cool off for 30-60 minutes. 
Solution 4: Check pressure switch, replace if damaged or inoperable. 

 
Issue: Excessive moisture in the safety valve. 

Solution 1: Depressurize and drain the tank. 
Solution 2: Relocate the compressor to a drier location. 

 
Issue: Continual cutting-off of Thermal overload protection. 

Solution 1: Relocate the compressor to a drier, cooler location. 
Solution 2: Replace the compressor. 

 
Issue: Excessive vibration or noise 

Solution 1: Tighten system components. 
Solution 2: Replace the compressor.  

 
Issue: Loss of pressure of tank when compressor is shut off. 

Solution 1: Tighten drain cock. 
Solution 2: Examine air and check valves and replace if damaged or leaking. 
Solution 3: Use soap and water solution on air connections, and tighten connections or repair leaks where needed. 
Solution 4: Replace safety valve, it may be defective. 

 
Issue: Compressor runs continuously and has low air flow. 

Solution 1: Decrease the frequency of use. 
Solution 2: Use soap and water solution on air connections, and tighten connections or repair leaks where needed. 
Solution 3: Clean or replace the air filter element if it is clogged.  
Solution 4: Replace compressor. 

 
Issue: Safety valve trips repeatedly due to overuse  

Solution 1: Replace pressure switch. 
Solution 2: Replace safety valve.

 

Summary of Contents for VXO4830AB

Page 1: ...water submerged parts Never leave this product unattended during use Intended for use by adults only During and immediately after use avoid touching any part of the compressor with bare hands as it is very hot during such periods Avoid use of product near flames explosive materials aerosol products or oxygen devices Be sure to pump nothing other than atmospheric air It is important to determine th...

Page 2: ...de and then drill Make sure the compressor is secured BRAIDED HOSE INSTALLATION Connect the stainless steel braided hose of the compressor to the tank s inlet port IMPORTANT The tank s inlet port must be 3 8 N P T National Pipe Thread REMOTE AIR FILTER INSTALLATION KIT Only use if you need to move compressor s air intake to an area other than where the compressor was installed A Braided Hose Brack...

Page 3: ...as to prevent condensation from entering into the gauge Dropping or disturbing the product can affect the product s accuracy For best results the air gauge should be installed perpendicular to the ground with the zero facing the bottom To tighten the pressure gauge into the air tank place a wrench over the square wrench flats to tum the gauge This is the proper way to avoid air leakage or damage S...

Page 4: ...l turn off If the compressor fails to reach the maximum air pressure of the tank which is the Pressure Switch s cut OFF pressure check all air connections for leaks While the compressor is pumping use soapy water or any bubble solution to perform this check In case the leak remains after tightening re apply thread sealant CAUTION Never touch fittings braided hose or the air compressor with bare ha...

Page 5: ...sor Issue Excessive vibration or noise Solution 1 Tighten system components Solution 2 Replace the compressor Issue Loss of pressure of tank when compressor is shut off Solution 1 Tighten drain cock Solution 2 Examine air and check valves and replace if damaged or leaking Solution 3 Use soap and water solution on air connections and tighten connections or repair leaks where needed Solution 4 Repla...

Reviews: