PAGE 3 of 5

 

 

AIR TANK 

MOUNTING 

  Find a convenient mounting location in your vehicle for the air tank. Ensure ports are reachable before drilling 

any holes. 

  Mark the location of holes using the mounting brackets of the air tank as a template, and then drill to size.  

  Using mounting hardware provided, secure the air tank. 

IMPORTANT

: Do not mount on a flexible material. 

 

The installation location of your tank’s accessories depends on your air system’s configuration. 

 
PORT LOCATIONS AND THREAD SIZE (NPT) 
 

 

 
PRESSURE SWITCH RATING 

  The included pressure switch has a rating of 170 PSI ON, 200 PSI OFF. When the air pressure in the air tank 

is below the preset ON pressure (170 PSI), the compressor will automatically turn on and will start pumping 
air into the tank. When the pressure reaches the cut OFF pressure (200 PSI), the compressor will be 
automatically shut off. 

 

AIR PRESSURE GAUGE 

 

In one of the Air Tank’s 1/4" NPT ports, using the thread sealant provided, install the air pressure gauge. 

  The side or top of the tank is the best location to use as to prevent condensation from entering into the gauge. 

 

Dropping or disturbing the product can affect the product’s accuracy. 

  For best results, the air gauge should be installed perpendicular to the ground, with the zero facing the 

bottom. 

  To tighten the pressure gauge into the air tank, place a wrench over the square wrench flats to tum the 

gauge. This is the proper way to avoid air leakage or damage.  

 

SAFETY VALVE 

  Your system comes with a safety valve designed specifically to release pressure from the air tank 

automatically if 250 PSI is exceeded. This will help prevent an accident in case of pressure switch failure. 

 

DRAIN VALVE 

  This valve helps you drain the water that can collect in the air tank after long periods of use. 

REMOVING CONDENSATION

 

To remove any condensation which has accumulated inside the tank, bleed the tank’s pressure until it ranges 
from approximately 5 PSI to 20 PSI. 

 

Remove the drain valve found at the tank’s bottom to drain the water from the tank. After draining the 
accumulated condensation, reinstall the drain valve. 

 

IMPORTANT

: Draining the system regularly will extend the life of the air tank. 

 

THREAD SEALANT 

  Your system includes Premium Thread Sealant, make sure to use it on all thread connections to ensure 

proper air sealing. 

Summary of Contents for VXO4830AB

Page 1: ...water submerged parts Never leave this product unattended during use Intended for use by adults only During and immediately after use avoid touching any part of the compressor with bare hands as it is very hot during such periods Avoid use of product near flames explosive materials aerosol products or oxygen devices Be sure to pump nothing other than atmospheric air It is important to determine th...

Page 2: ...de and then drill Make sure the compressor is secured BRAIDED HOSE INSTALLATION Connect the stainless steel braided hose of the compressor to the tank s inlet port IMPORTANT The tank s inlet port must be 3 8 N P T National Pipe Thread REMOTE AIR FILTER INSTALLATION KIT Only use if you need to move compressor s air intake to an area other than where the compressor was installed A Braided Hose Brack...

Page 3: ...as to prevent condensation from entering into the gauge Dropping or disturbing the product can affect the product s accuracy For best results the air gauge should be installed perpendicular to the ground with the zero facing the bottom To tighten the pressure gauge into the air tank place a wrench over the square wrench flats to tum the gauge This is the proper way to avoid air leakage or damage S...

Page 4: ...l turn off If the compressor fails to reach the maximum air pressure of the tank which is the Pressure Switch s cut OFF pressure check all air connections for leaks While the compressor is pumping use soapy water or any bubble solution to perform this check In case the leak remains after tightening re apply thread sealant CAUTION Never touch fittings braided hose or the air compressor with bare ha...

Page 5: ...sor Issue Excessive vibration or noise Solution 1 Tighten system components Solution 2 Replace the compressor Issue Loss of pressure of tank when compressor is shut off Solution 1 Tighten drain cock Solution 2 Examine air and check valves and replace if damaged or leaking Solution 3 Use soap and water solution on air connections and tighten connections or repair leaks where needed Solution 4 Repla...

Reviews: