VIVOTEK
338 - User's Manual
tour_i<0~19>_checklist string[512]
1/4
The
indexes of preset positions, separated
by “,”
tour_i<0~19>_dwelltime
string[512]
1/4
Preset tour: time to wait before moving to
the next preset position, separated by “,”
Recorded tour: number of seconds to wait
before continuing a loop tour.
7.43 UART control
Group:
uart
(capability_nuart > 0 and capability_fisheye = 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40]
1/4
Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128]
1/4
Full path of the PTZ driver.
enablehttptunnel
<boolean>
1/4
Enable HTTP tunnel channel to control UART.
Group:
uart_i<0~(n-1)>
n is uart port count
(capability_nuart > 0 and capability_fisheye = 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
baudrate 300,600,1200,2400
,4800,9600,19200,
38400,57600,11520
0
4/4
Set baud rate of COM port.
databit
5,6,7,8
4/4
Data bits in a character frame.
paritybit none,
odd,
even
4/4
For error checking.
stopbit 1,2 4/4
"1"
: One stop bit is transmitted to indicate
the end of a byte.
"2"
: Two stop bits are transmitted to indicate
the end of a byte.
If you want to transfer the stopbit for 150%
of the normal time used to transfer one bit,
the uart_i<0~(n-1)>_stopbit should be set
as 2 and the uart_i<0~(n-1)>_databit set as
5 as well.
uartmode
rs485,
4/4
RS485 or RS232.