VIVOTEK
User's Manual - 195
greater than 0400a.
profile_i<0~(m-1)>_sharpness
<Not recommended to use this>
-3~3,100
4/4
-5: Less saturation <-> 5: More saturation
100: Use "
image_c<0~(n-1)>_saturationpercent"
* Only available when bit 2 of
"capability_image_c<0~(n-1)>_basicsetting"
is 1.
* We replace "profile_i0_saturation" with
"profile_i0_saturationpercent".
* This parameter will not be used after the
version number (httpversion) is equal or
greater than 0400a.
profile_i<0~(m-1)>_brightness
percent
0~100
4/4
Set brightness in the normalized range.
0: Darker <-> 100: Bright
* Only available when bit 0 of
"capability_image_c<0~(n-1)>_basicsetting"
is 1.
profile_i<0~(m-1)>_contrastpe
rcent
0~100
4/4
Set contrast in the normalized range.
0: Less contrast <-> 100: More contrast
* Only available when bit 1 of
"capability_image_c<0~(n-1)>_basicsetting"
is 1
profile_i<0~(m-1)>_saturation
percent
0~100
4/4
Set saturation in the normalized range.
0: Less saturation <-> 100: More saturation
* Only available when bit 2 of
"capability_image_c<0~(n-1)>_basicsetting"
is 1.
profile_i<0~(m-1)>_sharpness
percent
0~100
4/4
Set sharpness in the normalized range.
0: Softer <-> 100: Sharper
* Only available when bit 3 of
"capability_image_c<0~(n-1)>_basicsetting"
is 1
profile_i<0~(m-1)>_gammacur
ve
0~100
4/4
0: Fine-turned gamma curve by Vivotek.
1: Gamma value = 0.01