VIVOTEK
282 - User's Manual
© 2019 VIVOTEK INC. All Right Reserved
158
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
exposurewin.mode
.blc:disabled:,
aespeed:disabled:,
exposurelevel:hidd
en:,
exposurelevel:fixed
:<x>,
exposurelevel:fixed
:<x>/<x>,
exposurelevel:rang
ed:<x>-<x>,
exposuremode:fixe
d:auto
<x>: nonnegative
integer
<product
dependent>
affected functions are list here.
The format is "Affect API
name":"Policy":"Description"
"Policy" can be categorized into
following groups:
- (disabled) : UI turns grey and users
can't select it.
- (unchanged) : UI keeps the status as
before and user can't change it.
- (hidden) : UI is hidden.
- (fixed) : UI is fixed to one selection or
value.
- (ranged) : UI is fixed to multiple
selections or values.
- (enabled) : UI is checked.
- (notsupport) : the affected function
is not available.
"Affect API name" can be described in
hierarchy, such as
"exposurewin.mode.blc:disabled:"
which means blc exposure window is
disabled. API name can be one word
as well, such as
"exposurelevel:fixed:6" which means
exposurelevel is fixed to level 6.
"Description" can be a nonnegative
integer or string or NULL.
For example:
"exposurelevel:fixed:6/8/12" which
means exposurelevel is fixed to level
6, level 8 and level 12.
"-" means no feature is affected.
* When "wdrpro"=0, this value must
be "-"
wdrpro_description
<string>
0/7
Description about WDR Pro mode.
* Only available when
Summary of Contents for FD9360-H