6-input Seamless Scaler Switcher & HDBaseT Receiver
17
6.3 RS232 Communication Commands
Communication protocol:
RS232 Communication Protocol
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
6.3.1 RS232 Control Mode Switching
Command
Function
Feedback Example
50787%
Enable RS232 control mode 1: Control
the Scaler Switcher or third-party device
from local.
RS232 Mode 1: RS232
Control Scaler & Remote
50788%
Enable RS232 control mode 2: Control
the Scaler Switcher or third-party device
from remote.
RS232 Mode 2: RS232
Control Scaler
/+[X]:******
Set communication between PC and
HDBaseT receiver.
X is for baud rate, its value ranges
from 1 to 7 (1--2400, 2--4800,
3--9600,
4--19200,
5--38400,
6
—57600, 7--115200)
***** is for data (max 48 Byte)
None
6.3.2 Input Signal Switching
Command
Function
Feedback Example
50701%
Switch to 1-HDMI/MHL input.
Switch to HDMI 1
50702%
Switch to 2-HDMI input.
Switch to HDMI 2
50703%
Switch to 3-HDMI input.
Switch to HDMI 3
50704%
Switch to 4-HDMI input.
Switch to HDMI 4
50705%
Switch to 5-DP input.
Switch to DP
50706%
Switch to VGA/YPbPr/AV input.
Switch to VGA
50680%
Set the signal format to VGA for 6-VGA
input.
Input 6 Set & Switch to VGA
50681%
Set the signal format to YPbPr for 6-VGA
input.
Input 6 Set & Switch to
YPbPr
50682%
Set the signal format to AV(C-video) for
6-VGA input.
Input 6 Set & Switch to AV
50631%
Get the input source.
Input:
xx
(xx=
HDMI1/
Summary of Contents for VL120026