Programacion_1
55.fm - 31/1/12
STARTING UP AND PROGRAMMING
VIVO-D102 Control board
49
3
PROGRAMMING SEQUENCE
Before entering the programming menus, it is
necessary to close the door or disconnect the device
and then reconnect.
Press the ENTER button to access the programming
menus.
The display shows “
C
”
1
01
or “
C
”
1
0
2
.
Use the keys ^ and
V
to select the required values,
and confirm by pressing ENTER.
Use ESC to go back to the previous display.
To leave the programming menu, press ESC several
times until the display goes off or shows
CL
.
1
Programme the prior conditions (see “Prior
Conditions Programming (D1= “
C
”)” on page 49).
2
Programme the radio codes, along with the door
open/close (see “Radio code programming (only
with RSD) and door open/close programming (D1=
“
P
”)” on page 50).
3
Programme the functioning mode and the
automatic standby time (see “Main Functions
Programming (D1= “
F
”)” on page 50).
4
Programme the advanced functions (see “Advanced
Functions Programming (D1= “
A
”)” on page 51).
Prior Conditions Programming (D1= “
C
”)
1
Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2
Press the buttons ^ and
V
until D1 shows the letter
C
flashing. Press ENTER to confirm.
D2 flashes.
3
Press the buttons ^ and
V
until the required D2
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
4
Press the buttons ^ and
V
until the required D3 and
D4 value appears (see chart). Press ENTER to
confirm.
If “motor turning direction” is selected after
pressing ENTER, the display shows
. At this point
the door can be operated using the ^ and
V
buttons
to check turning direction. Press ESC to finish the
check.
5
Press ESC to return to the previous display.
Display
D1
D2
D3 - D4
?
or
CL
ENTER
á
Select the value
using ^ and
V
ENTER
á
Select the value
using ^ and
V
ENTER
á
Select the value using
^ and
V
ESC
à
ESC
à
ENTER
(confirming)
à
ESC
(unconfirmed)
à
C
1
0 x
General navigation through the programming parameters and menus
D1
D2
Parameter
D3
D4
Predetermined
option
Options
C
1
Motor turning direction
0
1
x
0
2
4
Disabled
5
Closing safety device (photocell
or strip)
0
0
x
Device not installed
1
0
Device without testing
1
1
Device with testing