2.

 

Sound 

Description 

Enable beeper feedback. 1: Enabled (default) / 0: Disabled.

 

Size  

Format 

Enumerated 

Read only 

No 

Min Value 

Max Value 

Default Value 

 

3.

 

Down-Cast Light 

Description 

Enable the down-cast light. 1: Enabled (default) / 0: Disabled.

 

Size  

Format 

Enumerated 

Read only 

No 

Min Value 

Max Value 

Default Value 

 

4.

 

Application-Level Retries 

Description 

Number of attempts on top of the stack-level retries to try to reach the 

controller/hub with Z-Wave messages.

 

Size  

Format 

Unsigned Integer 

Read only 

No 

Min Value 

Max Value 

10 

Default Value 

 

5.

 

Battery-Poll Timer 

Description 

Amount of time in minutes between timed battery checks.

 

Size  

Format 

Unsigned Integer 

Read only 

No 

Min Value 

Max Value 

1440 

Default Value 

70 

 

Summary of Contents for KP01

Page 1: ...ly Operating Frequency 908 42Mhz 916Mhz Operating Temperature 32 f to 120 f Battery Type 4xAA Battery Life 1 year approximate based on usage Z Wave Plus V Certified S2 Encryption Smart Start Enabled W...

Page 2: ...pad and the device s downcast light should blink several times green every ten seconds while to indicate that the keypad is actively looking to be included into a network The keypad must not already b...

Page 3: ...l There are two methods to removing the Keypad from a Z Wave network exclusion and performing a factory reset see section on Factory Reset 1 Follow the controller s instructions on putting the control...

Page 4: ...per switch in a hole big enough for a paperclip 2 Insert a paperclip into the hole until you feel the button depress 3 Hold the button down for ten seconds The green downcast indicator will blink rapi...

Page 5: ...Entry Control 1 Manufacturer Specific Manufacturer ID 0x0156 Product Type 0x4B50 Product ID 0x0001 Association The keypad supports one Association group which is the Lifeline group of able to have on...

Page 6: ...default 0 Disabled Size 1 Format Enumerated Read only No Min Value 0 Max Value 1 Default Value 1 4 Application Level Retries Description Number of attempts on top of the stack level retries to try to...

Page 7: ...y 0x0C Alarming 0x0D Alarming Burglar 0x0E Alarming Smoke 0x10 Bypass Challenge 0x11 Entry Delay 0x12 Exit Delay Target State 1 Away 2 Stay 0x13 Alarming Medical 0x14 Alarming Freeze 0x15 Alarming Wat...

Page 8: ...Type Event Home Security 0x07 Tampering Covering Removed 0x09 Motion Detected Unknown Location 0x08 Power Management 0x08 Replace Battery Soon 0x0A Replace Battery Now 0x0B Supervision When included...

Page 9: ...exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interferen...

Reviews: