Installation Manual

Thermostat Application Guide

Description

Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Heat Only Systems
Cool Only Systems
Millivolt

Yes

Yes
Yes
Yes
Yes
Yes

Power Type

Battery Power

Hardwire (Common Wire)

Hardwire (Common Wire) with 

Battery Backup

Table of Contents

Installation Tips

Thermostat Quick Reference

Private Label Badge

Wiring

Wiring Diagrams

Technician Setup Menu

Programming

Features 

Specifications

 

Page

A trained, experienced 

technician must install this 

product.

Carefully read these 

instructions.  You could damage 

this product or cause a 

hazardous condition if you fail 

to follow these instructions.

Una version en espanol de este 

manual se puede descargar en 

la pagina web de la compania.

Rev. 1821

     U.S. Registered Trademark. Patents pending

Copyright      2018 All Rights Reserved.

5-7

8

13-19

2-4

Yes
Yes

20-28

Mount Thermostat

Align the 4 tabs on the subbase with 

corresponding slots on the back of the 

thermostat, then push gently until the 

thermostat snaps in place.

Installation Tips

Note:

 To ensure a solid fit between the 

thermostat and the subbase:

1. 

Mount subbase to a flat wall

2.

 Use screws provided

3.

 Drywall anchors should be flush with the wall

4.

 Wires should be pushed into the wall

Installation Tips

The thermostat should be installed approximately 4 to 5 feet above the 

floor.  Select an area with average temperature and good air circulation.

•  Close to hot or cold air ducts

•  That are in direct sunlight

•  With an outside wall behind the thermostat

•  In areas that do not require conditioning

•  Where there are dead spots or drafts (in corners or behind doors)

•  Where there might be concealed chimneys or pipes

Wall Locations

Pick an installation location that is easy for the user to access.  The temperature 

of the location should be representative of the building.

Installation Tip

Do not install thermostat in these locations:

Installation Tips

29-30

31

Vertical Mount

Horizontal Mount

For horizontal mount put one screw on 
the left and one screw on the right.

All of our products are mercury free. However, if the product you are 

replacing contains mercury, dispose of it properly.  Your local waste 

management authority can give you instructions on recycling and 

proper disposal.

Mercury Notice

Failure to disconnect the power before beginning to install this product 

can cause electrical shock or equipment damage.

Installation Tip: Electrical Hazard

For vertical mount put one screw on 
the top and one screw on the bottom.

Subbase Installation

11-12

9-10

Wired Remote Sensing

Yes

Vive Comfort

Toll Free : 888-776-1427 

Web: www.vivecomfort.com

Hours of Operation: M-F 9AM - 6PM Eastern 

TP-S-855CR

P.O. Box 3377

Springfield, MO 65804

Summary of Contents for TP-S-855CR

Page 1: ...res should be pushed into the wall Installation Tips The thermostat should be installed approximately 4 to 5 feet above the floor Select an area with average temperature and good air circulation Close to hot or cold air ducts That are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doo...

Page 2: ...per can be installed between E and W2 to turn thermostat into a single stage control for Emergency Heat Operation Thermostat Quick Reference The low battery indicator is displayed when the AA battery power is low If the user fails to replace the battery within 21 days the screen will only show the low battery indicator but maintain all functionality If the user fails to replace the batteries after...

Page 3: ...em TypicalHeatOnlySystemWithFan TypicalCool OnlySystem HEAT RELAY RC RH Y C W E G C R L2 L1 HOT FAN RELAY HEAT RELAY RC RH Y C W E G C R L2 L1 HOT FAN RELAY COMPRESSOR RELAY C R L2 L1 HOT RC RH Y C G Power supply Factory installed jumper Remove only when installing on 2 transformer systems Use either O or B terminals for changeover valve Optional24VACcommonconnectionwhenthermostatisusedinbatterypo...

Page 4: ...nt to exit the Technician Setup options 4 Press the DONE key to exit Keypad Lockout Note The selected keypad lockout functionality must be activated after exiting tech setup If you do not perform this procedure all keys will function freely To lock the keypad hold down the and keys for 3 seconds You will see a lock in the display To unlock the display hold down the and keys for 3 seconds The compr...

Page 5: ...periods per day 4 time periods areWake Leave Return Sleep 2C time periods are Occupied Unoccupied 4C time periods are Occupied 1 Unoccupied 1 Occupied 2 Unoccupied 2 Use the or key to select 4 2c or 4c time periods per day 4 OFF OFF dL If ON is selected the beep will sound If OFF is selected there is no sound 4 OFF OFF ON b Tech Setup Steps Adjustment Options Default LCDWillShow Contractor Call Nu...

Page 6: ...XT 7 Minutes are now flashing Use the or key to select current minutes 8 Press DONE when completed All our programmable thermostats are shipped with an energy saving default program You can customize this default program by following the instructions in the set program schedule section starting on page 24 Programming Your thermostat can be programmed to have each day of the week programmed uniquel...

Page 7: ...5 Press NEXT 6 The setpoint temperature is flashing Use the or key to make your setpoint selection for that day s WAKE OCC1 period 7 Press NEXT 8 Repeat steps 4 through 7 for that day s LEAVE UNOCC1 time period for that day s RETURN OCC2 time period and for that day s SLEEP UNOCC2 time period To customize your 7 day 4 time period Program schedule follow these steps Monday Repeat steps 4 through 8 ...

Page 8: ...nent holds Temporary Permanent Hold Feature Programming A Note About Programmable Fan The programmable fan feature will run the fan continuously during any time period it is programmed to be on This is the best way to keep the air circulated and to eliminate hot and cold spots in your building If using IAQ mode set fan to IAQ for any time period 1 Select HEAT or COOL with the SYSTEM key Note You h...

Reviews: