Power supply

Factory-installed jumper. Remove only when installing on 2-transformer systems 

Use either O or B terminals for changeover valve

Optional 24 VAC common connection when thermostat is hardwired with battery backup mode.

5

NOTE:

In many heat pump systems with no emergency heat relay a jumper can be installed between E and W2.

WIRING

4

2

1

COMPRESSOR 

RELAY

FAN RELAY

HEAT RELAY

C

R

L2

L1 (HOT)

Typical 2H/2C system: 1 transformer

Typical 2H/2C system: 2 transformer

COMPRESSOR 

RELAY

FAN RELAY

HEAT RELAY

4

2

1

C

R

L2

L1 (HOT)

C

R

L2

L1 (HOT)

REMOVE JUMPER 

Typical heat-only system

HEAT RELAY

4

2

1

C

R

L2

L1 (HOT)

FAN RELAY

4

2

1

C

R

L2

L1 (HOT)

COMPRESSOR

 RELAY

Typical cool-only system

Typical heat-only system with fan

FAN RELAY

4

2

1

C

R

L2

L1 (HOT)

HEAT RELAY

Typical 3H/2C heat pump system

FAN RELAY

1

C

R

L2

L1 (HOT)

COMPRESSOR

 RELAY

COOL CHANGE OVER 

VALVE

4

O
B

COMPRESSOR 

RELAY 2

HEAT RELAY 2

COMPRESSOR 

RELAY 2

HEAT RELAY 2

HEAT CHANGE OVER 

VALVE

COMPRESSOR

 RELAY 2

AUXILIARY

2

3

EMERGENCY HEAT 

RELAY

1

Summary of Contents for S-855C Series

Page 1: ...ttery Power Hardwire Common Wire Hardwire Common Wire with Battery Backup Power Type 1 Specifications Rev 1413 A trained experienced technician must install this product Carefully read these instructi...

Page 2: ...there are dead spots or drafts in corners or behind doors Where there might be concealed chimneys or pipes Pick an installation location that is easy for the user to access The temperature of the loca...

Page 3: ...the bottom edge of the badge Gently turn the screwdriver counter clockwise The badge is held on by a magnet The badge should pry off easily Do not use force Magnet in door Use the bevel on lower ridge...

Page 4: ...disconnect the power before beginning to install this product can cause electric shock or equipment damage Caution Mercury Notice Vertical Mount Horizontal Mount Vertical Mount Horizontal Mount 4 SUBB...

Page 5: ...Typical 2H 2C system 1 transformer Typical 2H 2C system 2 transformer COMPRESSOR RELAY FAN RELAY HEAT RELAY 4 2 1 C R L2 L1 HOT C R L2 L1 HOT REMOVE JUMPER Typical heat only system HEAT RELAY 4 2 1 C...

Page 6: ...l System 2 Heat 2 Cool Heat Pump System 3 Heat 2 Cool Heat Pump System RC RH C B O G W E Y Y2 W2 Transformer Power cooling Transformer Power heating Transformer common Energized in heating Energized i...

Page 7: ...ompressor delay of 5 minutes when the thermostat detects a power outage from the hardwired power supply Important High quality alkaline batteries are recommended Rechargeable batteries or low quality...

Page 8: ...r example A swing setting of 0 5 F will turn the heating on at approximately 0 5 F below the setpoint and turn the heating off at approximately 0 5 F above the setpoint The cooling swing setting is ad...

Page 9: ...lock setting 12 Hour Clock Morning Recovery This feature will start heating early to bring the building temperature to its programmed setpoint by the beginning of the time period WAKE OCCUPIED Use the...

Page 10: ...ption will turn the heat pump off 45 seconds after the auxiliary heat relay turns on For 2 heat applications the first stage will turn off 45 seconds after the auxiliary stage turns on For 3 heat appl...

Page 11: ...to select OFF 1YEAR 2YEAR IAQ Cell Reminder Will remind the user to change the PHI Cell after 25 000 hrs Use the or key to select OFF 250 Stands for 25000 hours IAQ Mode Cycle This feature will confi...

Page 12: ...rent hour When using 12 hour time make sure the correct a m or p m choice is selected Press NEXT Minutes are now flashing Use the or key to select current minutes Press DONE when completed 1 2 3 4 5 6...

Page 13: ...n OCC 2 Sleep UNOCC 2 Occupied Unoccupied Wake OCC 1 Leave UNOCC 1 Return OCC 2 Sleep UNOCC 2 Occupied Unoccupied Wake OCC 1 Leave UNOCC 1 Return OCC 2 Sleep UNOCC 2 Occupied Unoccupied Occupied Unocc...

Page 14: ...me period and for Saturday SLEEP UNOCC2 time period Repeat steps 4 through 7 for Sunday WAKE OCC1 time period for Saturday LEAVE UNOCC1 time period for Sunday RETURN OCC2 time period and for Saturday...

Page 15: ...PROGRAMMING 15 If you want to use IAQ mode during this time period select IAQ with the fan key Sunday time If you want to use IAQ mode during this time period select IAQ with the fan key...

Page 16: ...riod begins Your program setpoint will then replace your temporary setpoint Permanent hold If you press the HOLD key at the bottom of your screen you will see HOLD appear below the setpoint temperatur...

Reviews: