INSTALLATION MANUAL

4

5-6

7

8-11

12-15

16

Installation Tips
Themostat Quick Reference
Subbase Installation
Wiring

Technician Setup Menu

Mounting and Battery Installation

Features & Specifications

2
3

Thermostat Applications Guide

Table of Contents

Page

Description

Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat) 
Heat Pump (with Aux. or Emergency Heat)
Multi-stage Systems
Heat Only Systems
Cool Only Systems
Millivolt

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Battery Power
Hardwire (Common Wire)
Hardwire (Common Wire) with Battery Backup

Power Type

1

Specifications

Rev. 1413

A trained, experienced technician 

must install this product. 

Carefully read these instructions. You 

could damage this product or cause a 

hazardous condition if you fail to follow 

these instructions. 

Patents and Trademarks pending.

Copyright © 2013. All rights reserved.

Una versión en español de este 

manual se puede descargar en la 

página web de la compañía.

VIVE Comfort

1111 S. Glenstone Ave., Suite 2-100

Springfield, MO 65804

Toll-Free:

 1-800-776-1635   

Web:

 www.vivecomfort.com

Hours of Operation:

 M-F 9AM - 6PM Eastern

TP-S-855C

C O M F O R T

TM

5:23

PM

F

Tue

Menu

Auto

Off

Summary of Contents for S-855C Series

Page 1: ...ttery Power Hardwire Common Wire Hardwire Common Wire with Battery Backup Power Type 1 Specifications Rev 1413 A trained experienced technician must install this product Carefully read these instructi...

Page 2: ...there are dead spots or drafts in corners or behind doors Where there might be concealed chimneys or pipes Pick an installation location that is easy for the user to access The temperature of the loca...

Page 3: ...the bottom edge of the badge Gently turn the screwdriver counter clockwise The badge is held on by a magnet The badge should pry off easily Do not use force Magnet in door Use the bevel on lower ridge...

Page 4: ...disconnect the power before beginning to install this product can cause electric shock or equipment damage Caution Mercury Notice Vertical Mount Horizontal Mount Vertical Mount Horizontal Mount 4 SUBB...

Page 5: ...Typical 2H 2C system 1 transformer Typical 2H 2C system 2 transformer COMPRESSOR RELAY FAN RELAY HEAT RELAY 4 2 1 C R L2 L1 HOT C R L2 L1 HOT REMOVE JUMPER Typical heat only system HEAT RELAY 4 2 1 C...

Page 6: ...l System 2 Heat 2 Cool Heat Pump System 3 Heat 2 Cool Heat Pump System RC RH C B O G W E Y Y2 W2 Transformer Power cooling Transformer Power heating Transformer common Energized in heating Energized i...

Page 7: ...ompressor delay of 5 minutes when the thermostat detects a power outage from the hardwired power supply Important High quality alkaline batteries are recommended Rechargeable batteries or low quality...

Page 8: ...r example A swing setting of 0 5 F will turn the heating on at approximately 0 5 F below the setpoint and turn the heating off at approximately 0 5 F above the setpoint The cooling swing setting is ad...

Page 9: ...lock setting 12 Hour Clock Morning Recovery This feature will start heating early to bring the building temperature to its programmed setpoint by the beginning of the time period WAKE OCCUPIED Use the...

Page 10: ...ption will turn the heat pump off 45 seconds after the auxiliary heat relay turns on For 2 heat applications the first stage will turn off 45 seconds after the auxiliary stage turns on For 3 heat appl...

Page 11: ...to select OFF 1YEAR 2YEAR IAQ Cell Reminder Will remind the user to change the PHI Cell after 25 000 hrs Use the or key to select OFF 250 Stands for 25000 hours IAQ Mode Cycle This feature will confi...

Page 12: ...rent hour When using 12 hour time make sure the correct a m or p m choice is selected Press NEXT Minutes are now flashing Use the or key to select current minutes Press DONE when completed 1 2 3 4 5 6...

Page 13: ...n OCC 2 Sleep UNOCC 2 Occupied Unoccupied Wake OCC 1 Leave UNOCC 1 Return OCC 2 Sleep UNOCC 2 Occupied Unoccupied Wake OCC 1 Leave UNOCC 1 Return OCC 2 Sleep UNOCC 2 Occupied Unoccupied Occupied Unocc...

Page 14: ...me period and for Saturday SLEEP UNOCC2 time period Repeat steps 4 through 7 for Sunday WAKE OCC1 time period for Saturday LEAVE UNOCC1 time period for Sunday RETURN OCC2 time period and for Saturday...

Page 15: ...PROGRAMMING 15 If you want to use IAQ mode during this time period select IAQ with the fan key Sunday time If you want to use IAQ mode during this time period select IAQ with the fan key...

Page 16: ...riod begins Your program setpoint will then replace your temporary setpoint Permanent hold If you press the HOLD key at the bottom of your screen you will see HOLD appear below the setpoint temperatur...

Reviews: