![Vivax HZB-12/A User Manual Download Page 55](http://html.mh-extra.com/html/vivax/hzb-12-a/hzb-12-a_user-manual_1038216055.webp)
7
1. Open the cover, remove the ice basket and pour water into tank.
Keep water level below the water level mark.
2. Press “Power” button on the control panel to begin the ice making cycle.
3. Select the ice cube size by pressing the “Select” button. If the room temperature is lower
than 1
5℃
, it is recommended to select small ice cube in order to avoid ice sticking together.
4. The ice making cycle lasts approx. 5 to 13 minutes, depending on seletion of ice cube size
and the room temperature. The recommended ice making room temperature is between
1
0℃ to 38℃
5. If water pump can’t inject water, the ice maker will stop automatically, and the “Add Water”
indicator will be on.Press “Power” button, fill water up to the max. water level mark and
press “Power” button again to turn on the unit again.Allow the refrigerant liquid inside the
compressor at least 3 minutes to settle before restarting.
6. The ice maker stops working when the ice basket is full and the “Ice” indicator will be on.
7. Change water in the water reservoir every 24 hours to ensure a reasonable hygiene level.
If unit isn’t to be used, drain all the water and dry the tank.
USING YOUR ICE MAKER
PROBLEM
POSSIBLE CAUSE
SOLUTION
“
Add Water” indicator is
on.
Lack of Water.
Stop the ice maker, fill water, and
press “Power” button again to
restart the unit.
“Ice” indicator is on.
Ice is full in basket.
Remove ice from ice basket.
Continuous press “Select”
button 5 seconds, the unit
could make ice 10 cycles even
“Ice” indicator is on.
Ice cubes stick together.
The ice making cycle is too
long.
Stop the ice maker, and restart it
when the ice blocks melt. Select
the small size ice cube selection.
Water temperature in inner
tank is too low.
Replace the water. Temperature
of water recommended at 8
-
3
2℃
Ice making cycle is normal
but no ice formed.
Room temperature or
water temperature in inner
tank is too high.
The room temperature should be
5
-
40
℃
, water temperature should
be 8
-
3
2℃
Refrigerant in cooling
system leaks.
Verify by a qualified technician.
Pipe in the cooling system
is blocked.
Verify by a qualified technician.
TROUBLESHOOTING
Summary of Contents for HZB-12/A
Page 2: ...Upute za uporabu Ledomat HR BiH CG IM 121T RoHS 2002 95 EC ...
Page 14: ...Korisničko uputstvo Ledomat SR BiH CG IM 121T RoHS 2002 95 EC ...
Page 25: ...Упатства за употреба Ледомат MAK IM 121T RoHS 2002 95 EC ...
Page 36: ...Udhëzime për shfrytëzim Prodhues akulli AL IM 121T RoHS 2002 95 EC ...
Page 47: ...User manual Ice maker ENG IM 121T RoHS 2002 95 EC ...
Page 71: ......
Page 73: ...www vivax com ...
Page 74: ...www vivax com ...