ENG
VIVAX
41
or
deformation
of
the
unit
due
to
the
heat.
Do
not
install
the
heat
pump
at
any
place
where
flammable
gas
may
leak
out.
If
the
gas
leaks
out
and
stays
around
the
heat
pump,
a
fire
may
break
out.
The
appliance
is
not
intended
for
use
by
young
children
or
infirm
persons
without
supervision.
Young
children
should
be
supervised
to
ensure
that
they
do
not
play
with
the
appliance.
The
outdoor
unit
window
‐
shades
should
be
periodic
cleaning
in
case
of
being
jammed.
This
window
‐
shapes
is
heat
dissipation
outlet
of
components,
if
being
jammed
will
cause
the
components
shorten
their
service
life
spans
because
of
overheated
for
a
long
time.
The
temperature
of
refrigerant
circuit
will
be
high,
please
keep
the
interconnection
cable
away
from
the
copper
tube.
OPERATION
AND
PERFORMANCE
Protection
Equipment
This
Protection
Equipment
will
enable
the
Heat
Pump
to
stop
when
the
Heat
Pump
is
to
be
directed
running
compulsively.
The
protection
equipment
may
be
activated
in
following
conditions:
Cooling
Operation
●
The
air
inlet
or
air
outlet
of
outdoor
unit
is
blocked.
●
Strong
wind
is
Continuously
blowing
to
the
air
outlet
of
the
outdoor
unit.
Heating
Operation
●
Too
much
rubbish
adhere
to
the
filter
in
the
water
system
●
The
air
outlet
of
indoor
unit
is
choked
●
Mishandling
in
operation:
If
mishandling
happens
because
of
lighting
or
mobile
wireless,
please
shut
off
the
manual
power
switch,
and
turn
on
again,
then
push
the
ON/OFF
button
NOTE
When
the
protection
equipment
starts,
please
shut
down
the
manual
power
switch,
and
restart
operation
after
problem
is
solved.
About
Power
Cut
If
power
is
cut
during
operation,
stop
all
the
operation
immediately
Power
comes
again.
If
the
auto
‐
restant
function
is
set
on,
then
the
unit
will
auto
‐
restart.
Heating
capacity
The
heating
operation
is
a
heat
‐
pump
process
that
heat
will
be
absorbed
from
outdoor
air
and
released
to
indoor
water.
Once
the
outdoor
temperature
is
decreased,
heating
capacity
decreased
corredpindingly.
Other
heating
equipment
is
suggested
to
be
used
together
when
outdoor
temperature
is
too
low.
Summary of Contents for HPS-120HM155AERI/I1s
Page 2: ......
Page 60: ... HR VIVAX 57 DODATAK B Dijagram ožičenja s električnim upravljanjem 4 10kW ...
Page 64: ... HR VIVAX 1 ...
Page 95: ...VIVAX HR 32 STRUKTURA IZBORNIKA PREGLED ...
Page 96: ... HR VIVAX 33 ...
Page 129: ...VIVAX ENG 28 Electronic control box 12 14 16 kW 1 phase ...
Page 159: ...VIVAX ENG 58 ANNEX B Electrically controlled wiring diagram 4 10kW ...
Page 163: ......
Page 164: ... ENG VIVAX 1 ...
Page 195: ...VIVAX ENG 32 MENU STRUCTURE OVERVIEW ...
Page 196: ... ENG VIVAX 33 ...
Page 229: ...ZZZ 9 9 FRP ...