,QVWDOODWLRQ0DQXDO
&KHFNDIWHU,QVWDOODWLRQDQG7HVW2SHUDWLRQ
$LU3XUJLQJDQG/HDNDJH7HVW
2XWGRRU&RQGHQVDWH'UDLQDJHRQO\IRUKHDWSXPSXQLW
&KHFNDIWHU,QVWDOODWLRQ
&RQQHFWFKDUJLQJKRVHRIPDQLIROGYDOYHWRFKDUJHHQGRIORZSUHVVXUHYDOYH
ERWKKLJKORZSUHVVXUHYDOYHVPXVWEHWLJKWO\VKXW
&RQQHFWMRLQWRIFKDUJLQJKRVHWRYDFXXPSXPS
)XOO\RSHQWKHKDQGOHRI/RPDQLIROGYDOYH
2SHQWKHYDFXXPSXPSIRUYDFXXPL]DWLRQ$WWKHEHJLQQLQJVOLJKWO\ORRVHQ
MRLQWQXWRIORZSUHVVXUHYDOYHWRFKHFNLIWKHUHLVDLUFRPLQJLQVLGH,IQRLVHRI
YDFXXPSXPSKDVEHHQFKDQJHGWKHUHDGLQJRIPXOWLPHWHULV7KHQWLJKWHQ
WKHQXW
.HHSYDFXXPLQJIRUPRUHWKDQPLQVDQGPDNHVXUHWKHUHDGLQJRIPXOWL
PHWHULV;
SDFP+J
)XOO\RSHQKLJKORZSUHVVXUHYDOYHV
5HPRYHFKDUJLQJKRVHIURPFKDUJLQJHQGRIORZSUHVVXUHYDOYH
7LJKWHQOLGRIORZSUHVVXUHYDOYH$VVKRZQLQ)LJ
'XULQJKHDWLQJRSHUDWLRQWKHFRQGHQVDWHDQGGHIURVWLQJZDWHUVKRXOGEHGUDLQHG
RXWUHOLDEO\WKURXJKWKHGUDLQKRVH,QVWDOOWKHRXWGRRUGUDLQFRQQHFWRULQDĭ
KROHRQWKHEDVHSODWHDQGDWWDFKWKHGUDLQKRVHWRWKHFRQQHFWRUVRWKDWWKHZDVWH
ZDWHUIRUPHGLQWKHRXWGRRUXQLWFDQEHGUDLQHGRXW7KHKROHGLDPHWHUPXVWEH
SOXJJHG:KHWKHUWRSOXJRWKHUKROHVZLOOEHGHWHUPLQHGE\WKHGHDOHUVDFFRUGLQJWR
DFWXDOFRQGLWLRQV
Items to be checked
Possible malfunction
Has it been fixed firmly?
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage test?
It may cause insufficient cooling(heating)
capacity
Is heat insulation sufficient?
It may cause condensation and dripping.
Is water drainage satisfactory?
It may cause condensation and dripping.
Is the voltage in accordance with the rated
voltage marked on the nameplate?
It may cause electric malfunction
or damage the product.
Is the electric wiring and piping
connection installed correctly and securely?
It may cause electric malfunction
or damage the part.
Has the unit been connected to a secure
earth connection?
It may cause electrical leakage.
Is the power cord specified?
It may cause electric malfunction
or damage the part.
Are the inlet and outlet openings blocked? It may cause insufficient cooling(heating)
capacity.
Is the length of connection pipes
and refrigerant capacity been recorded?
The refrigerant capacity is not accurate.
Fig.6
Manometer
-76cmHg
Low-pressure
valve (Lo) Open
Liquid valve
Gas valve
High-pressure
valve (Hi) closed
Charging hose
Vacuum
pump
Drain-water hole
Bottom frame
Hose (available commercially,
inner dia. 16mm)
Drain connecter
Summary of Contents for ACP-12CH35GEF
Page 1: ...ACP 12CH35GEF Service manual ENG RoHS ...
Page 2: ......
Page 5: ...ACP 12CH35GEF ACP 12CH35GEF I ...
Page 6: ...ACP 12CH35GEF O ...
Page 8: ...Model W H D ACP 12CH35GEF I 790 265 177 051 506 5 3 Unit mm K21 D W H ACP 12CH35GEF O ...
Page 11: ...Outdoor unit Model ACP 12CH35GEF O ...
Page 12: ......
Page 27: ......
Page 28: ... SORGHG 9LHZV DQG 3DUWV LVW Model ACP 12CH35GEF I ...
Page 29: ...ACP 12CH35GEF I ...
Page 30: ...Model ACP 12CH35GEF O ...
Page 31: ...ACP 12CH35GEF O ...
Page 53: ......
Page 54: ......
Page 55: ......