Trouble shooting
19
Loose screws
Tighten them.
Worn bearings
Replace the motor if knocking sounds continue when
running or loose, or the motor hums or noise appears to be
internal while running.
Voltage
Check voltage. Call Supply Authority if not within limits.
Wiring
Check the wire connections, if loose, repair or replace the
terminal. If wires are off, refer to wiring diagram for
identification, and replace. Check wire locations. If not per
wiring diagram, correct.
Main PCB failure
Check voltage of main PCB. Replace the main PCB if
open.
Capacitor (Discharge
capacitor before testing)
Check the capacitor.
Replace if not /-10% of manufacturers rating.
Replace if shorted, open, or damaged.
Room temp sensor
Check the temperature setting if not at the coolest (in
cooling mode) or the warmest (in heating mode). Set it if
not.
Compressor will
not run while fan
motor runs.
Compressor
Check the compressor for open circuit or ground. If open or
grounded, replace the compressor.
Excessive noise.
Copper tubing
Remove the cabinet and carefully rearrange tubing not to
contact cabinet, compressor, shroud and barrier.
Water depth is over load
in chassis(P1)
Use a drain hose and a pan to drain the condensed water
in the chassis.
Water depth sensor if
failure
Check and replace if failure.
Water full alarm
shaded pole motor failure
Check and replace if the motor is failure.
Air filter
Clean or replace if restricted.
Air discharge pipe
Realign and assemble if the installation of the air
discharging pipe failure. Replace if damaged.
Unit undersized
Determine if the unit is properly sized for the area to be
cooled or heated.
Condenser and
Evaporator
Clean or replace if restricted.
shaded pole motor failure
Check and replace if the motor is failure.
Fan motor
Check the fan capacitor and replace if not /-10% of
manufactures rating.
Air flow
Clean or remove if any barrier is found to block the
inlet/outlet wind flow of the unit.
Less refrigerant
Check the tubes for reasons of leakage. Recycle the
refrigerant, correct the leakage points and recharge.
Cooling or
heating feels not
good
Capillary tube
Regulate the flow if capillary tube and make the
evaporating temperature appropriate if the evaporator is
frosted. Replace if blocked. Repair joint if leaking.