![Vivax ACP-09PT25AEB Service Manual Download Page 21](http://html.mh-extra.com/html/vivax/acp-09pt25aeb/acp-09pt25aeb_service-manual_1038046021.webp)
Trouble shooting
18
10 Trouble
shooting
PROBLEM POSSIBLE
CAUSE REMEDY
Power failure
Check the power supplier if the power supplier is supplied
to the unit. Check the power cord and correct if damaged.
Transformer (Discharge
transformer before
testing)
Check resistance between the two input/output lines on
transformer. Replace the transformer if either of the
input/output is open or the transformer is damaged.
No power display
on panel or any
one of the buttons
failure.
Display board or main
PCB failure
Check the voltage on display board. Replace the display
board if it is +5V else replace the main PCB.
Remote control
failure.
Battery failure
Check the voltage of battery. Replace batteries if the
voltage is lower than 2.3V.
Check voltage. Call an electrician if not within limits.
Test capacitor.
Replace if not /-10% of manufacture's rating.
Check bearings. Replace the motor if the blower wheel
cannot rotate freely.
Fan motor runs
intermittently
Cycles on overload.
Pay attention to any change from high speed to low speed.
Replace the motor if the speed does not change.
Refrigerant
The amount of the refrigerant is too much, making the
compressor load too big. Recycle and recharge the
refrigerant after checking for the reason.
Compressor
stops instantly
after startup.
Compressor
The compressor is blocked inside. Replace after checking
for the reason.
No power
Check voltage at electrical outlet. Correct if none.
Water alarm
Check and correct if water alarm happens.
Power supply cord
Check voltage at the power cord terminal on Main PCB.
Replace the power cord if none.
Transformer (Discharge
transformer before
testing)
Check resistance between the two input/output lines on
transformer. Replace the transformer if either of the
input/output is open or the transformer is damaged.
Wire disconnected or
connection loose
Connect wire. Refer to wiring diagram for terminal
identification. Repair or replace loose terminal.
Main PCB failure
Select fan speed and Check the voltage on main PCB.
Replace the main PCB if no voltage in anyone.
Capacitor (Discharge
capacitor before testing)
Test capacitor.
Replace if not /-10% of manufacture's rating.
Replace if shorted, open or damaged.
Fan motor will not
run.
Will not rotate
Fan blower hitting scroll. Realign assembly.
Check fan motor bearings. Replace the motor if motor
shaft do not rotate.
Fan motor noise.
Fan blower
Replace the fan blower if cracked, out of balance, or