Now sweep left and right over the Sonde to obtain a second peak. Note that there are no 
ghost signals when sweeping left to right over the Sonde. 

 

Now push the Sonde in a couple of meters and repeat the above to mark the pipe or duct 
route. Keep the insertion intervals small 

(2 to 3m)

 to ensure the Sonde is not lost.

Vivax-Metrotech Corp. (Headquarters)

3251 Olcott Street, Santa Clara, CA 95054, USA
T/Free: 1-800-446-3392
Tel: +1-408-734-1400
Fax: +1-408-734-1415
Email: [email protected]
Website: www.vivax-metrotech.com

Visit us at 

www.vivax-metrotech.com

 to view our full product line and worldwide locations.

Summary of Contents for vScan D18

Page 1: ... inspection cameras Sondes come in a variety of sizes which ties into how deep they can be located Different frequen cies are available which allow sondes to be located in metallic or non metallic pipes and ducts The vScan receiver has sonde frequencies of 33kHz 512Hz and 640Hz P N 4 04 000223 Page 1 Sonde Range Model Depth and Dimensions Frequency Battery Type D18 Sonde D38 Sonde D64 Sonde D23 So...

Page 2: ...he camera or duct rodder When working with sondes always use a fresh battery Use a radio system or mobile phone for communication Work in increments of 10 to 20 feet 3 to 6m Locate mark move and repeat TIP MAIN PEAK GHOST PEAK GHOST PEAK 1 2 3 Turn on the vScan Receiver Use the mode paddle to enter the Sonde mode The Sonde icon will now be visible on the screen Position the vScan above the Sonde a...

Page 3: ... 75 Now move the vScan forward and back to detect the largest signal You will also notice that there will be a ghost signal in front and behind the Sonde This is normal and characteristic of locating Sondes Ghost Peak Ghost Peak Main Peak Forward Back Locate Left Right position Locate ...

Page 4: ...peat the above to mark the pipe or duct route Keep the insertion intervals small 2 to 3m to ensure the Sonde is not lost Vivax Metrotech Corp Headquarters 3251 Olcott Street Santa Clara CA 95054 USA T Free 1 800 446 3392 Tel 1 408 734 1400 Fax 1 408 734 1415 Email SalesUSA vxmt com Website www vivax metrotech com Visit us at www vivax metrotech com to view our full product line and worldwide locat...

Reviews: