ELECTRICAL CONNECTION
•
The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
•
Protection against the parts under tension must be ensured after the building-in.
•
The data of connection necessary are on the stickers place on the hob casing near the
connection box.
•
The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
•
The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
Caution!
This appliance can only be connected to a network 230 V~ 50/60 Hz.
You should always connect the earth wire.
Respect the connection diagram.
Use the connecting cable that is attached to the device.
The green / yellow wire corresponds to the earth wire, the blue wire corresponds to the neutral
wire and the brown wire correspond to the phase.
* calculated with the simultaneous factor following the standard EN 60335-2-6
Ensure that the cables are correctly inserted and tightly screwed down.
4 weeks after installation, be sure to tighten again the screws in the terminal block.
Mains
Connection
Cable diameter
Cable
Protection calibre
230V~ 50/60Hz
1 Phase + N
3 x 1,5 mm²
H 05 VV - F
H 05 RR - F
16 A *
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.