background image

USER MANUAL

GIOVE AC5

Summary of Contents for Giove AC5

Page 1: ...USER MANUAL GIOVE AC5...

Page 2: ......

Page 3: ...acts 7 4 2 3 Changing View Contacts 7 4 2 4 Change Communication Mode 8 4 3 Web Server 9 4 3 1 State 9 4 3 2 Configuration Local IP 10 4 3 3 Connection Configuration 11 4 3 4 Control Contacts 12 4 3 5...

Page 4: ...cated on the marking label Do not allow anything to rest on the power cord Do not locate this product where persons will walk on the cord Never push objects of any kind into this product through the c...

Page 5: ...possible to connect the Giove AC5 to the local network and manage it with Vivaldi iControl or a home automation supervisor It includes an integrated web server where you can manually control the conta...

Page 6: ...g connector B A for power supply and RS485 connection with other devices Giove AC5 D Five multicolour LED matching to the relay used to display relay status E Power ON LED indicates that the device is...

Page 7: ...n single module For proper operation of the device you need to feed it through the connector Figure 1 C from 12 to 24 Vdc Attention to the polarity For communication connecting the LAN to the RJ45 con...

Page 8: ...nnector 4 way in parallel Figure 1 C and connect the LAN network cable only to the first device It will be necessary then to set a unique ID in the devices from 1 to 5 See Section 4 2 The power supply...

Page 9: ...ID 11 15 To confirm the selection there will be a quick flashing of the five LEDs in red To quit the menu either wait or press the button P4 4 2 2 Changing the Status of Contacts To perform a manual...

Page 10: ...D 4 Confirming with the P1 button you enter the menu of choice between LED 1 Protocol Mod Bus LED 2 Protocol Standard AC5 Press P1 to confirm your choice it will be a quick flashing of the LED for con...

Page 11: ...rnet browser Firefox Chrome Safari etc and enter the Default IP address on the address bar The authentication window will open then you can enter the default username and password User admin default P...

Page 12: ...4 3 2 Configuration Local IP Figure 4 On this page you can change the network parameters of the Giove AC5 To save the changes made click on the button Save GIOVE AC5 10...

Page 13: ...Connection Configuration Figure 5 On this page you can configure the port and the communication protocol with the home automation controller To save the changes made click on the button Save 11 GIOVE...

Page 14: ...ntacts and request information about the firmware version and hardware of the Giove AC5 In the drop down list you can select the destination device ID connected to the first Giove AC5 for each is poss...

Page 15: ...ystem Configuration Figure 7 On this page you can change the name of Giove AC5 the ports number of the web server user name and password To save the changes made please click on the button Save 13 GIO...

Page 16: ...4 3 6 Restart Figure 8 On this page you can restart the device remotely GIOVE AC5 14...

Page 17: ...Relay 3 0 Off 1 On Byte 5 Relay 4 0 Off 1 On Byte 6 Relay 5 0 Off 1 On Byte 7 Byte not used Byte 8 CR String end equivalent to 13 in decimal or 0x0D in hexadecimal 5 1 3 Command Example ASCII String...

Page 18: ...through the ModBus protocol you must write in the registers as in the table Relay 1 registry 5 0 OFF 1 ON Relay 2 registry 6 0 OFF 1 ON Relay 3 registry 7 0 OFF 1 ON Relay 4 registry 8 0 OFF 1 ON Rela...

Page 19: ...6 TECHNICAL SPECIFICATIONS Supply Voltage 12 24Vdc Maximum Current 200mA Maximum Current of contacts in deviation NO 5A NC 3A Network Connection 10 100Mbps 17 GIOVE AC5...

Page 20: ...www vivaldigroup it info vivaldigroup it Vivaldi S R L Administrative Headquarters Via E Fermi 8 Z I Est 30020 Noventa di Piave VE Italy tel 39 0421 307825 fax 39 0421 307845 info vivaldigroup it www...