CONNECTING THE FEEDER CABLE
To connect the feeder cable to the hob it is necessary to carry out the following opera-
tions:
• Unscrew the screw
A
of the terminal board at the bottom of the hob (fig. 4.5).
• Unlock the 2 clips
B
and open the cover
C
.
• Unscrew the screw
D
and open completely the cable clamp
E
(figs. 4.7 - 4.8 - 4.9).
• Position the U bolts
F
onto terminal board
G
(figs.
4
.7 - 4.8 - 4.9) according to the
diagrams in fig. 4.6.
• Connect the phase and earth wires to terminal board
G
according to the diagrams in
fig. 4.6.
• Strain the feeder cable and block it with cable clamp
E
(by screwing screw
D
).
• Close the cover
C
of the terminal board
G
and block it with the screw
A
.
FEEDER CABLE SECTION
“Type H05VV-F or H05V2V2-F or H05RR-F”
For 60 cm and 80 cm models:
220-240 V
~
3 x 2.5 mm
2
(**)
380-415 V 3N
~
5 x 1.5 mm
2
(**)
380-415 V 2N
~
4 x 2.5 mm
2
(**)
For 90 cm models:
220-240 V
~
3 x 4 mm
2
(**)
380-415 V 2N
~
4 x 2,5 mm
2
(**)
380-415 V 3N
~
5 x 2.5 mm
2
(**)
21
A
B
C
B
Fig.4.5
(**) Connection with wall box connection.
– Diversity factor applied
– A diversity factor may be applied to
the total loading of the appliance only
by a suitably qualified person.