24
EN
1. Press the “ON/OFF” button (15) to
turn the device off;
2. Press the batteries cover fixing
tab (4) and open the batteries
compartment cover (5);
3. Remove the discharged batteries
and insert the new or rechargeable
batteries. Make sure the batteries are
inserted according to the polarity (+/-)
shown in the side areas;
4. Close the cover and make sure the
tab is well fixed;
When the charge level indicator
is too low, the batteries shall be
replaced.
4. OPERATING
INSTRUCTIONS
This device measures length, height
and calculates areas and volumes.
This laser was designed to measure
distances both indoors and outdoors.
To ensure a safe operation, it is
necessary to consider the following
aspects:
�
Before using, check if every fixing
screw is properly tightened. It is
important to check regularly the laser
to ensure every safety issues and
performance;
�
Prevent the device from bumping
or falling. Laser damage can impair
accuracy;
�
The reception lens and the laser
ray outlet must not be covered or
obstructed while measuring;
�
Keep the laser ray outlet and the
reception lens always clean;
�
In case of a strong presence of light,
and to obtain a better visibility of the
laser ray, use laser glasses, a target
plate for the laser beam or shade the
target surface;
The duration and quality of the
measurements depend on the distance,
the light conditions and the reflective
properties of the target surfaces.
There are surfaces that may cause
measuring errors:
�
Clear surfaces (glass, water);
�
Reflective surfaces (polished metal,
glass);
�
Porous surfaces (insulating material);
�
Surfaces with structures (rough
plaster, natural stone);
�
Inclined surfaces;
On these cases, a target plate shall be
used over the surfaces.
4.1 - TURN THE DEVICE ON/
OFF
1. To turn the device on, press “ON/
OFF” button (15) until the display (1)
shows some data;
2. To turn the device off, press the
“ON/OFF” button until the information
disappears from the display;
3. If any button is pressed while
operating:
- 30 seconds – The laser turns off;
- 180 seconds – The device turns off;
Never leave the device without
surveillance. Turn it off after using it.
4.2 - MEASURING UNIT
SELECTION
To change the measuring unit, press
the measurement unit button (18) and
choose between: m, ft., in and ft. + in.
4.3 -CHANGE THE
MEASUREMENT REFERENCE
POINT (FIG. C)
When measuring, it is possible to
consider two reference points: the front
and back of the device.
To change the measurement reference
point, press the measurement reference
point button (14). The device has an
acoustic sign when the reference point
is changed. The selected reference
point is presented on the display in the
area for the reference point (20, 21);
Every time the device is turned on, the
reference point is the back by default.
4.4 -BACK / CLEAR
When measuring, press the “CLEAR”
button (16) to erase the last action or
the measured value.
4.5 - SIMPLE MEASUREMENT
1. Press the measurement button (9) to
turn the laser on;
2. Press again the same button to start
measuring. The measured value is
immediately shown;
4.6 - CONTINUOUS
MEASUREMENT (MIN/MAX)
(FIG. D)
1. Press the continuous measurement
button (11) to activate the mode. The
maximum and minimum distances are
shown on the display.
2. Press the measurement button (9)
or the “CLEAR” button (16) to disable
the continuous measurement mode;
The last measured value is shown on
the overview line.
4.7 - AREAS CALCULATION
(FIG. E)
1. Press the function button (10) once
and the symbol
is shown in the
display field for the measurement mode
Summary of Contents for REDEYE VIMDAVL60
Page 4: ...C C L L P A A V 4 PT Fig F Fig C Fig D Fig E Fig H Fig G 1 2 1 2 3...
Page 37: ...OBSERVA ES OBSERVACIONES COMMENTS OBSERVATIONS...
Page 38: ...OBSERVA ES OBSERVACIONES COMMENTS OBSERVATIONS...
Page 39: ......
Page 40: ...RUA DA G NDARA 664 4520 606 S JO O DE VER STA MARIA DA FEIRA PORTUGAL MI_VIMDAVL60_REV01_FEV19...