2. DC Application
- DC terminals are only for charging
12V battery;
- Concerning the automatic type
battery with the leads, be sure to
disconnect the negative leads of the
battery while charging.
CAUTION:
Connect the positive
and negative poles of the battery
with the positive and negative poles
of DC terminals separately. Do not
confuse them, otherwise the battery
and generating set will burn out;
Do not connect the positive pole of
the battery with its negative pole,
other-wise the battery damage will
result;
Do not connect the positive pole of
the DC terminal with its negative
pole, otherwise the generator will
be damaged;
When a large capacity battery is
charged, excessive current flows,
the fuse for the direct current will
burn out.
Do not run the generator while it is
still connected with the battery.
Do not use DC12V and AC at the
same time.
3. Dimensioning
Electrical Appliance particularly
motor-driven equipments will produce
very High current while starting, the
bellow table provides the reference
for connecting these apparatus to the
generator.
Type
Power (w)
Typical Electrical
Appliance
Example
Start
Rated
Electrical Appliance
Start
Rated
Incandescent
Lamp
Heating
Appliance
x 1
x 1
Incandescent
Lamp
TV
Incandescent
Lamp
100 W
100 VA
(W)
100 VA
(W)
Fluorescent
Lamp
x 2
x 1.5
Fluorescent
Lamp
Fluorescent
Lamp
40 W
80VA (W) 60VA (W)
Motor driven
Equipment
x 3~5
x 2
Fridge
Fan
150 W
450-750
VA (W)
300 VA
(W)
VIII. STOP THE GENERATOR
- Disconnect the load from the
generator.
- Turn off the air switch of the
generator.
- Let the generator work without
load for about 1 minutes.
- Do not stop the engine suddenly,
otherwise the generator will be
damaged.
- Concerning the electric starter,
turn the key to “OFF“.
WARNING:
If the engine keep on
running even after the speed lever
is placed at the “STOP” position,
either turn the fuel cock to the
“CLOSE” position or loosen the nut
of high pressure fuel pipe on the
pump side to stop the engine.
Do not stop the engine with the
decompression lever.
F14
EN
28