background image

5

011.02.1108

In 5L connect bolt extender (6055) and latch 

(6050) (5L.6).

In 5R note the position of the prepared holes 

in (6016) for the handle and lock. Assemble 

the door handle as shown (5R.6).

Ensure that the door is totally square before 

tightening all bolts. This can be done by 

measuring the diagonals.

Connect the plastic door guides (6057) onto 

bar (6014) with screws (6062) (5.2). 

Loosely connect the door wheels (6049) and 

door jump clips (6039) to bottom bar (6017) 

using bolt (6046), washers (6051) and nut 

(3002) (5.4). These should be tightened when 

the door is later fitted in the building.

Repeat for both doors and lay them aside for 

later use.

 6. veNtS  

The position of vents is determined by the 

location of the prepared holes in eave angle 

(6072).

Note:

 

Warm window seal (6034) to room 

temperature!

 Press seal (6034) centrally onto 

the top edge of glass pane (C) (6.1). 

Do not 

stretch.

 

Make a cut into the seal at the corner (6.2) and 

then press the seal onto the side and bottom 

edges of pane (C), cutting to fit around each 

corner. 

Fit vent bottom bar (6024) over the seal 

(6.3) and then side bars (6020) and (6021). 

Connect these at the corners using screws 

(1003) (6.4).

Finish pressing the seal onto the top edge and 

cut to length in the middle. Fit the top vent bar 

(6025) and connect to side bars (6020) and 

(6021) with screws (1003) (6.5).

Ensure that the vent is totally square before 

tightening all screws. 

Loosely connect bar (6066) using bolt (3001) 

onto eave angle (6072) using the prepared 

holes (6.6).

Remove side brace (6003) and diagonal brace 

(6008) to fit vent sill (6019) behind them (6.7).

Replace (6003) and then (6008), loosely 

connecting with nut (3002) (6.7) (6.8). Do 

not tighten until the roof vent is assembled in 

building. 

Repeat for all vents and lay them aside for 

later use.

 7. glazINg  

 

Please note the already mentioned safety 

precautions.

Ensure that the U/V protected face of all 

polycarbonate sheets is on the outside.

With one person using the step ladder inside 

the building, glaze the roof by sliding panes 

(D),(E) and (F) into the appropriate guides in 

the roof bars (6087) and (6088) (7.2) (7.3). 

When adjacent panes are in place connect 

ends (6077), (6078) or (6079) using screws 

(7349) (7.4) to prevent them sliding out of the 

guides.

Position door guide bar (6074) onto eave 

angle (6072) / (6073) and fix in place using 3 

equally spaced screws (6068) (7.6) (7.7).

Press the glazing seals (1020) onto all side 

bars (6013) and (6022) (7.5) and cut to length. 

Fit the glazing panes (G), (H) and (J) as 

shown and fix by pressing plastic fixing strips 

(6030) or (6032) onto each side (7.6) & (7.7).

Now tighten the bolts connecting the building 

to the foundation.

 8. PoSItIoNINg of veNtS aND DooRS

 

Lift the vents into the prepared positions in 

the sides by loosening bar (6066) and sliding 

bar (6025) into bar (6066) from one end (8.1) 

& (8.2). Lift vent sill bar (6019) and fit it to the 

vent. When correctly positioned tighten all 

bolts on the inside.

Bolt the vent opener (1067) onto bar (6024) 

using screws (6062) (8.3).

Connect both vent fixers (6056) onto sill bar 

(6019) using screws (6062) (8.3).

Place the plastic cap (1019) over the end of 

the window opener (1067) (8.3).

Position the doors by inserting the plastic door 

guides (6057) into bar (6074) (8.4) (8.5) and 

then lower the wheels onto the door track on 

bar (6002) (8.6). Hook the door jump clips 

(6039) under the lip on (6002) and tighten the 

door wheel bolts (6046) (8.6) (8.7).

Connect plastic nut caps (6070) by pushing 

them onto all visible nuts (3002) inside the 

building (8.8).

Connect down pipe elbow (1402) to down 

pipe (1415). At 3 not adjacent corners connect 

the down pipe assembly (1402) / (1415) to 

eave ends (6067) (8.9). Hook clamp (1414) 

onto corner bars (6022) at the height of elbow 

(1402) and insert screw (1006) into the prepa-

red hole in (1414) (8.10). Use the ø 20 drill to 

make the drainage holes in the 3 eave ends 

(6067) noting the marked area.

Inside the greenhouse slide glazing spacers 

(6075) or (6076) onto eave angles (6072) / 

(6073). Fix these to eave angle (6072) central-

ly using screw (7349). (8.11) (8.12).

 fINIShINg 

 

If desired, it is possible to seal the greenhouse 

at the edges and between the glazing and 

spacers (6075) or (6076) using neutral silicone. 

Silicone is not in cluded.

Place the warning label inside the building.
A full range of greenhouse accessories, to 

help you make the most of this product, is 

available from your stockist. Please inform 

yourself as to the possibilities.

 Safety NotIce 

 

In the event of high wind conditions, close the 

doors and all vents. 
In the event of heavy snowfall, clear the roof  

of the building or take suitable measures to 

support the roof. Heat the building in winter.

 commeNtS 

 

For the complete protection of your new 

green house, we advise you to include it in 

your 

house insurance.

 Please take note  

of possible building rules relating to the  

positioning of greenhouses.
Please stick the included greenhouse model 

label onto the door bar (6014) after success-

fully assembling this product. This information 

is important in the event that replacement 

parts are later required. 
Please keep these Assembly Instructions in a 

safe place, for future reference!
Our policy is one of continuous improvement 

and we reserve the right to change the specifi

-

cations without prior notice.

Summary of Contents for Hera 2 9000

Page 1: ...011 02 1108 Hera 2 9000 Assembly instructions Montageanleitung Montagevejledning Monteringsanvisning D DK S...

Page 2: ...Quantity 9000 6005 2 1797 2 6007 2 951 2 6008 1 1151 10 6013 1 2 1797 12 6014 5L R 458 2 6015 5L 436 1 6016 5R 436 1 6017 5L R 436 2 6019 6 636 3 6020 6 803 3 6021 6 803 3 6022 1 2 1797 6 6023 5L R 17...

Page 3: ...5L R 6 12 24 6061 4B 6 17 2 6062 5L R 8 3 9 x 9 22 6066 6 610 3 6067 3 81 2 6 6068 7 3 5 x 13 18 6070 8 13 5 190 Item No Part Sect Ref Size mm Quantity 9000 6072 1 1854 5 6073 2 1854 1 6074 7 1854 6...

Page 4: ...ll be located use a treated wooden beam not more then 52mm wide B B Connect the wooden beams to the foun dation with 50mm long bolts not provided Foundations must extend down below the frost level Dia...

Page 5: ...g strips 6030 or 6032 onto each side 7 6 7 7 Now tighten the bolts connecting the building to the foundation 8 positioning of vents and doors Lift the vents into the prepared positions in the sides by...

Page 6: ...rofilen werden vorbehandelte witterungsbest ndige Holzleisten von mindestens 18 mm Dicke und max 32 mm Breite ben tigt die zwischen Aluminiumrahmen und Fundament montiert werden A A F r die T rseite e...

Page 7: ...rch eine Plastikfolie oder einen gedruckten Hinweis an den Kanten gekennzeich net Diese Seite muss nach au en zeigen Ent fernen Sie die Folie Die Scheiben D E und F in die vorgese henen F hrungsschien...

Page 8: ...har 5 identiske sider 2 side med d r Placer delene p jorden og bolt dem l st sammen se 2 1 til 2 6 I de lodrette sp r 6022 6013 6005 anbringes 1 ekstra bolt til at kunne fastg re tv rstiver 6004 og s...

Page 9: ...013 og 6022 se 7 5 og sk r gummilisten til i rette l ngde Monter glassene G H og J ved hj lp af monteringslisterne 6030 eller 6032 som vist i 7 6 og 7 7 Det anbefales at v re to personer til at foreta...

Page 10: ...ken och f st dem l st med bult och mutter Se 1 1 till 1 6 Kom ih g att f ra in extra bult i de lodr ta glasprofilerna 6022 6013 f r att senare kunna montera de v gr ta str vorna 6003 samt de diagonala...

Page 11: ...p av 6077 6078 och 6079 med skruv 7349 enligt 7 4 s att de ej glider ut F st takfotsf rst rkning 6074 p takfotspro filer 6072 6073 med j mna mellanrum med skruvar 6068 Se 7 6 7 7 r det sv rt att f dit...

Page 12: ...12 DIANA 0 011 02 1108 Hera 2 9000 30 x 20 mm 52 x 20 mm a a b b a a b b a a a a a a a a 3768 mm 3263 mm 22 mm 6001 6002 1884 mm 120...

Page 13: ...3 6072 6003 6001 6013 6008 6008 1092 6022 1 6 1 1 1 3 1 4 1 5 1 2 6072 6013 6013 6008 6003 6013 6001 6008 6022 6001 6003 6022 1 6 1092 6072 6022 6072 6013 1092 5x 1 3001 5x 12 3002 5x 12 6001 5x 1 600...

Page 14: ...14x 6002 1x 6004 2x 6005 2x 6007 2x 6013 2x 6022 1x 6073 1x 2 2 2 3 2 4 2 5 2 1 2 2 2 3 2 4 2 5 2 6 6005 6013 6002 6073 6004 6007 6007 6022 1092 6004 6005 6013 6004 6007 6005 6013 6002 6007 6022 6002...

Page 15: ...1 3 15 011 02 1108 Hera 2 9000 1092 6x 3001 24x 3002 24x 6067 6x 3 1 3 2 3 3 3 1 3 2 3 3 3 4 3 5 3 6 6022 6001 6008 6003 6022 1092 6072 6022 3 4 3 5 6067 6072 6072 3 6 6072 6067 6067 6072 6072...

Page 16: ...ra 2 9000 3001 25x 3002 25x 6087 6x 6095 1x 6097 6x 6098 1x 4 1 1055 mm x 6 6087 6087 6087 6097 6097 6097 6097 6097 6097 6095 4 3 4 4 4 5 4 6 4 2 6098 6095 3001 6087 6095 6098 6087 1055 mm 6097 6087 6...

Page 17: ...8x 3002 49x 6036 1x 6038 1x 6052 1x 6059 1x 6061 2x 6088 12x 6099 1x 4 8 4 10 4 10 4 7 6087 6 0 9 5 4 9 6088 4 10 4 7 4 9 4 8 4 11 1092 6022 6072 6073 6087 6088 6097 6088 6073 6005 6013 4 11 6052 6061...

Page 18: ...6051 4x 6055 1x 6057 2x 6060 12x 6062 2x 6085 1x 5 3 5 1 5 2 5 3 5 5 5 4 6023 6014 6017 6015 5 5 5L 6 6015 6060 3002 6050 6055 6031 5 6 5 2 1020 6057 6014 6062 3002 6060 6051 6049 6051 3002 6039 6046...

Page 19: ...6053 2x 6057 2x 6058 2x 6060 12x 6062 2x 5 2 5 1 5 5 5R 6 6016 6060 3002 6031 5 6 5 1 5 2 5 3 5 5 5 4 6014 6023 6016 6017 6040 6058 6042 6043 6044 6045 6048 6047 6053 6053 6041 6014 6062 5 3 6051 6049...

Page 20: ...3x 1 6024 3x 1 6025 3x 1 6034 3x 1 6066 3x 1 6 9 No 3 mm 9000 C 367 9591 750 x 610 3 Total 3 6 6 6 7 6 5 6 3 6 2 6 1 6019 6013 6019 6008 6003 6 8 3001 6 4 1003 6025 1003 6020 6024 6025 6021 6020 6 2 6...

Page 21: ...9701 1793 x 470 2 H 367 9681 982 x 610 3 J 367 9711 1793 x 610 12 Total 35 D D D E E E F E F F F G G H J J J 1020 6013 6022 1020 1020 6030 6030 6030 6030 6030 6030 6030 6030 6032 6032 6022 6030 6032...

Page 22: ...90x 6075 12x 6076 6x 7349 18x 8 1 8 2 8 3 8 4 8 5 8 6 8 7 8 7 8 6 8 2 8 1 8 8 8 4 C H 1019 6056 1067 6062 J C 6013 6066 6025 6066 8 3 6039 6002 6085 B 6002 6074 6057 A 1 2 8 8 8 11 6070 8 10 8 9 8 11...

Page 23: ......

Page 24: ...ostfach 170163 44060 Dortmund Deutschland Tel 49 231 941655 0 Fax 49 231 941655 99 www eph schmidt de verkauf eph schmidt de OPJ A S Volderslevvej 36 A Postboks 480 5260 Odense S Danmark Tel 45 66 15...

Reviews: